在严重主动脉瓣关闭不全的情况下使用 Impella 5.5:相对禁忌症

{"title":"在严重主动脉瓣关闭不全的情况下使用 Impella 5.5:相对禁忌症","authors":"","doi":"10.1016/j.atssr.2024.04.012","DOIUrl":null,"url":null,"abstract":"<div><p>Moderate or severe aortic insufficiency is a contraindication to transvalvular Impella left ventricular assist device (Abiomed) use out of concern for worsening valvular insufficiency and recirculation. This report describes the case of a 75-year-old man with severe eccentric aortic insufficiency and systemic hypoperfusion who was supported with a transvalvular Impella 5.5 device for 6 days as preoperative rehabilitation before aortic valve replacement. The Impella device provided adequate systemic tissue perfusion, and left ventricular function remained without signs of volume overload and recirculation. Moderate or severe aortic insufficiency may not be an absolute contraindication to transvalvular Impella use, although this is case dependent.</p></div>","PeriodicalId":72234,"journal":{"name":"Annals of thoracic surgery short reports","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2772993124001931/pdfft?md5=9e292501f338692b7c2e562015e9999a&pid=1-s2.0-S2772993124001931-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Impella 5.5 Use in the Setting of Severe Aortic Insufficiency: A Relative Contraindication\",\"authors\":\"\",\"doi\":\"10.1016/j.atssr.2024.04.012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Moderate or severe aortic insufficiency is a contraindication to transvalvular Impella left ventricular assist device (Abiomed) use out of concern for worsening valvular insufficiency and recirculation. This report describes the case of a 75-year-old man with severe eccentric aortic insufficiency and systemic hypoperfusion who was supported with a transvalvular Impella 5.5 device for 6 days as preoperative rehabilitation before aortic valve replacement. The Impella device provided adequate systemic tissue perfusion, and left ventricular function remained without signs of volume overload and recirculation. Moderate or severe aortic insufficiency may not be an absolute contraindication to transvalvular Impella use, although this is case dependent.</p></div>\",\"PeriodicalId\":72234,\"journal\":{\"name\":\"Annals of thoracic surgery short reports\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2772993124001931/pdfft?md5=9e292501f338692b7c2e562015e9999a&pid=1-s2.0-S2772993124001931-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of thoracic surgery short reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2772993124001931\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of thoracic surgery short reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772993124001931","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

出于对瓣膜功能不全恶化和再循环的担忧,中度或重度主动脉瓣关闭不全是经瓣 Impella 左心室辅助装置(Abiomed)的禁忌症。本报告描述了一名 75 岁男性患者的病例,他患有严重的偏心性主动脉瓣关闭不全和全身灌注不足,在主动脉瓣置换术前,他使用经瓣 Impella 5.5 装置支持了 6 天,作为术前康复治疗。Impella 装置提供了充足的全身组织灌注,左心室功能保持良好,没有出现容量超负荷和再循环的迹象。中度或重度主动脉瓣关闭不全可能不是经瓣 Impella 装置的绝对禁忌症,但这取决于具体情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impella 5.5 Use in the Setting of Severe Aortic Insufficiency: A Relative Contraindication

Moderate or severe aortic insufficiency is a contraindication to transvalvular Impella left ventricular assist device (Abiomed) use out of concern for worsening valvular insufficiency and recirculation. This report describes the case of a 75-year-old man with severe eccentric aortic insufficiency and systemic hypoperfusion who was supported with a transvalvular Impella 5.5 device for 6 days as preoperative rehabilitation before aortic valve replacement. The Impella device provided adequate systemic tissue perfusion, and left ventricular function remained without signs of volume overload and recirculation. Moderate or severe aortic insufficiency may not be an absolute contraindication to transvalvular Impella use, although this is case dependent.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
53 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信