在全肩关节置换术中,单皮质扣固定与经骨修复肩胛下肌腱相比强度更高

IF 2.9 2区 医学 Q1 ORTHOPEDICS
Phob Ganokroj, Alexander R Garcia, Justin F M Hollenbeck, Ryan J Whalen, Justin R Brown, Amelia Drumm, Trevor J McBride, Sunikom Suppauksorn, Toufic R Jildeh, Capt Matthew T Provencher
{"title":"在全肩关节置换术中,单皮质扣固定与经骨修复肩胛下肌腱相比强度更高","authors":"Phob Ganokroj, Alexander R Garcia, Justin F M Hollenbeck, Ryan J Whalen, Justin R Brown, Amelia Drumm, Trevor J McBride, Sunikom Suppauksorn, Toufic R Jildeh, Capt Matthew T Provencher","doi":"10.1016/j.jse.2024.07.019","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Subscapularis tendon (SSc) dysfunction following total shoulder arthroplasty (TSA) results in poor functional outcomes. There have been numerous SSc repair constructs tested biomechanically and clinically, however, none has been demonstrated as superior. Newer techniques and implants have emerged, but have not been fully tested.</p><p><strong>Hypothesis: </strong>We hypothesized that the unicortical button (UB) fixation will provide significantly improved restoration of the anatomic footprint and biomechanical properties when compared to transosseous (TO) repair of the SSc.</p><p><strong>Methods: </strong>A digital footprint of SSc humeral insertion was obtained in 6 pairs of fresh-frozen cadaveric shoulders using a three-dimensional (3-D) digitizer. A complete SSc tear was created, and each pair of shoulders was randomized to either SSc repair with UB or TO repair. Each specimen underwent a cyclic loading protocol followed by pull-to-failure. The failure load, elongation at failure, gapping failure, number of cycles until failure, the load at key gapping points (1 mm, 3 mm, 5 mm, and 10 mm) and the failure mode were recorded using high-resolution video recording. 3-D surfaces of the insertion footprint and repair site were obtained, and surface areas were calculated using a custom MATLAB script and laser scanner. Paired t-tests were conducted to compare differences between two repair groups.</p><p><strong>Results: </strong>Failure load was significantly higher in the UB group (382.4 N ± 56.5 N) than in the TO group (253.6 N ± 103.4 N, p=0.005). TO repair provided higher gapping at failure (28.8 mm ± 8.2 mm) than UB repair (10.4 mm ± 6.8 mm, p=0.0017). UB repair had significantly higher load at the 1-mm, 5-mm, and 10-mm gapping compared with TO repair with p=0.042, p=0.033, and p=0.0076, respectively. There were no significant differences between elongation failure, the difference in footprint area from native to repair states, or the percentage of restored footprint area between groups. (p=0.26, p=0.18 and p=0.21 respectively) CONCLUSION: The UB fixation showed a significantly lower gap at failure, higher failure load and number of cycles until failure, and higher gap loads compared with the traditional TO repair for SSc. Although more clinical research is necessary, the UB fixation that utilizes cortical bone presents promising results.</p>","PeriodicalId":50051,"journal":{"name":"Journal of Shoulder and Elbow Surgery","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Unicortical Button Fixation Provide Higher Strength Compared with Transosseous Repair for Subscapularis Tendon in Total Shoulder Arthroplasty.\",\"authors\":\"Phob Ganokroj, Alexander R Garcia, Justin F M Hollenbeck, Ryan J Whalen, Justin R Brown, Amelia Drumm, Trevor J McBride, Sunikom Suppauksorn, Toufic R Jildeh, Capt Matthew T Provencher\",\"doi\":\"10.1016/j.jse.2024.07.019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Subscapularis tendon (SSc) dysfunction following total shoulder arthroplasty (TSA) results in poor functional outcomes. There have been numerous SSc repair constructs tested biomechanically and clinically, however, none has been demonstrated as superior. Newer techniques and implants have emerged, but have not been fully tested.</p><p><strong>Hypothesis: </strong>We hypothesized that the unicortical button (UB) fixation will provide significantly improved restoration of the anatomic footprint and biomechanical properties when compared to transosseous (TO) repair of the SSc.</p><p><strong>Methods: </strong>A digital footprint of SSc humeral insertion was obtained in 6 pairs of fresh-frozen cadaveric shoulders using a three-dimensional (3-D) digitizer. A complete SSc tear was created, and each pair of shoulders was randomized to either SSc repair with UB or TO repair. Each specimen underwent a cyclic loading protocol followed by pull-to-failure. The failure load, elongation at failure, gapping failure, number of cycles until failure, the load at key gapping points (1 mm, 3 mm, 5 mm, and 10 mm) and the failure mode were recorded using high-resolution video recording. 3-D surfaces of the insertion footprint and repair site were obtained, and surface areas were calculated using a custom MATLAB script and laser scanner. Paired t-tests were conducted to compare differences between two repair groups.</p><p><strong>Results: </strong>Failure load was significantly higher in the UB group (382.4 N ± 56.5 N) than in the TO group (253.6 N ± 103.4 N, p=0.005). TO repair provided higher gapping at failure (28.8 mm ± 8.2 mm) than UB repair (10.4 mm ± 6.8 mm, p=0.0017). UB repair had significantly higher load at the 1-mm, 5-mm, and 10-mm gapping compared with TO repair with p=0.042, p=0.033, and p=0.0076, respectively. There were no significant differences between elongation failure, the difference in footprint area from native to repair states, or the percentage of restored footprint area between groups. (p=0.26, p=0.18 and p=0.21 respectively) CONCLUSION: The UB fixation showed a significantly lower gap at failure, higher failure load and number of cycles until failure, and higher gap loads compared with the traditional TO repair for SSc. Although more clinical research is necessary, the UB fixation that utilizes cortical bone presents promising results.</p>\",\"PeriodicalId\":50051,\"journal\":{\"name\":\"Journal of Shoulder and Elbow Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Shoulder and Elbow Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jse.2024.07.019\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Shoulder and Elbow Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jse.2024.07.019","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景:全肩关节置换术(TSA)后肩胛下肌腱(SSc)功能障碍会导致不良的功能效果。有许多肩胛下肌腱修复结构经过了生物力学和临床测试,但没有一种被证明具有优越性。更新的技术和植入物已经出现,但尚未经过全面测试:我们假设,与经骨(TO)修复 SSc 相比,单皮质按钮(UB)固定可显著改善解剖足迹的恢复和生物力学特性:方法:使用三维(3-D)数字化仪在 6 对新鲜冷冻的尸体肩部获得 SSc 肱骨插入的数字足迹。创建一个完整的 SSc 撕裂,每对肩部随机进行 SSc UB 修复或 TO 修复。每个标本都接受了循环加载方案,然后进行拉伸至破坏。使用高分辨率视频记录了失效载荷、失效时的伸长率、间隙失效、失效前的循环次数、关键间隙点(1 毫米、3 毫米、5 毫米和 10 毫米)的载荷以及失效模式。使用定制的 MATLAB 脚本和激光扫描仪获得了插入足迹和修复部位的三维表面,并计算了表面积。进行配对 t 检验以比较两组修复之间的差异:结果:UB 组的破坏载荷(382.4 N ± 56.5 N)明显高于 TO 组(253.6 N ± 103.4 N,P=0.005)。TO 修复的失败间隙(28.8 毫米 ± 8.2 毫米)高于 UB 修复(10.4 毫米 ± 6.8 毫米,p=0.0017)。与 TO 修复相比,UB 修复在 1 毫米、5 毫米和 10 毫米间隙处的载荷明显更高,分别为 p=0.042、p=0.033 和 p=0.0076。各组间的伸长失败率、从原生状态到修复状态的足底面积差异或恢复足底面积的百分比均无明显差异。(分别为 p=0.26、p=0.18 和 p=0.21)结论:与治疗 SSc 的传统 TO 修复术相比,UB 固定术显示出明显更低的失效间隙、更高的失效载荷和直至失效的循环次数,以及更高的间隙载荷。虽然还需要更多的临床研究,但利用皮质骨的 UB 固定术结果令人鼓舞。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Unicortical Button Fixation Provide Higher Strength Compared with Transosseous Repair for Subscapularis Tendon in Total Shoulder Arthroplasty.

Background: Subscapularis tendon (SSc) dysfunction following total shoulder arthroplasty (TSA) results in poor functional outcomes. There have been numerous SSc repair constructs tested biomechanically and clinically, however, none has been demonstrated as superior. Newer techniques and implants have emerged, but have not been fully tested.

Hypothesis: We hypothesized that the unicortical button (UB) fixation will provide significantly improved restoration of the anatomic footprint and biomechanical properties when compared to transosseous (TO) repair of the SSc.

Methods: A digital footprint of SSc humeral insertion was obtained in 6 pairs of fresh-frozen cadaveric shoulders using a three-dimensional (3-D) digitizer. A complete SSc tear was created, and each pair of shoulders was randomized to either SSc repair with UB or TO repair. Each specimen underwent a cyclic loading protocol followed by pull-to-failure. The failure load, elongation at failure, gapping failure, number of cycles until failure, the load at key gapping points (1 mm, 3 mm, 5 mm, and 10 mm) and the failure mode were recorded using high-resolution video recording. 3-D surfaces of the insertion footprint and repair site were obtained, and surface areas were calculated using a custom MATLAB script and laser scanner. Paired t-tests were conducted to compare differences between two repair groups.

Results: Failure load was significantly higher in the UB group (382.4 N ± 56.5 N) than in the TO group (253.6 N ± 103.4 N, p=0.005). TO repair provided higher gapping at failure (28.8 mm ± 8.2 mm) than UB repair (10.4 mm ± 6.8 mm, p=0.0017). UB repair had significantly higher load at the 1-mm, 5-mm, and 10-mm gapping compared with TO repair with p=0.042, p=0.033, and p=0.0076, respectively. There were no significant differences between elongation failure, the difference in footprint area from native to repair states, or the percentage of restored footprint area between groups. (p=0.26, p=0.18 and p=0.21 respectively) CONCLUSION: The UB fixation showed a significantly lower gap at failure, higher failure load and number of cycles until failure, and higher gap loads compared with the traditional TO repair for SSc. Although more clinical research is necessary, the UB fixation that utilizes cortical bone presents promising results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.50
自引率
23.30%
发文量
604
审稿时长
11.2 weeks
期刊介绍: The official publication for eight leading specialty organizations, this authoritative journal is the only publication to focus exclusively on medical, surgical, and physical techniques for treating injury/disease of the upper extremity, including the shoulder girdle, arm, and elbow. Clinically oriented and peer-reviewed, the Journal provides an international forum for the exchange of information on new techniques, instruments, and materials. Journal of Shoulder and Elbow Surgery features vivid photos, professional illustrations, and explicit diagrams that demonstrate surgical approaches and depict implant devices. Topics covered include fractures, dislocations, diseases and injuries of the rotator cuff, imaging techniques, arthritis, arthroscopy, arthroplasty, and rehabilitation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信