β-磷酸三钙原子探针断层扫描分析参数的优化。

IF 2.9 4区 工程技术 Q3 MATERIALS SCIENCE, MULTIDISCIPLINARY
Selase Torkornoo, Marc Bohner, Ingrid McCarroll, Baptiste Gault
{"title":"β-磷酸三钙原子探针断层扫描分析参数的优化。","authors":"Selase Torkornoo, Marc Bohner, Ingrid McCarroll, Baptiste Gault","doi":"10.1093/mam/ozae077","DOIUrl":null,"url":null,"abstract":"<p><p>The biocompatibility and resorption characteristics of β-tricalcium phosphate (β-TCP, Ca3(PO4)2) have made it a coveted alternative for bone grafts. However, the underlying mechanisms governing the biological interactions between β-tricalcium phosphate and osteoclasts remain elusive. It has been speculated that the composition at grain boundaries might vary and affect β-TCP resorption properties. Atom probe tomography (APT) offers a quantitative approach to assess the composition of the grain boundaries, and thus advance our comprehension of the biological responses within the microstructure and chemical composition at the nanoscale. The precise quantitative analysis of chemical composition remains a notable challenge in APT, primarily due to the influence of measurement conditions on compositional accuracy. In this study, we investigated the impact of laser pulse energy on the composition of β-TCP using APT, aiming for the most precise Ca:P ratio and consistent results across multiple analyses performed with different sets of analysis conditions and on two different instruments.</p>","PeriodicalId":18625,"journal":{"name":"Microscopy and Microanalysis","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization of Parameters for Atom Probe Tomography Analysis of β-Tricalcium Phosphates.\",\"authors\":\"Selase Torkornoo, Marc Bohner, Ingrid McCarroll, Baptiste Gault\",\"doi\":\"10.1093/mam/ozae077\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The biocompatibility and resorption characteristics of β-tricalcium phosphate (β-TCP, Ca3(PO4)2) have made it a coveted alternative for bone grafts. However, the underlying mechanisms governing the biological interactions between β-tricalcium phosphate and osteoclasts remain elusive. It has been speculated that the composition at grain boundaries might vary and affect β-TCP resorption properties. Atom probe tomography (APT) offers a quantitative approach to assess the composition of the grain boundaries, and thus advance our comprehension of the biological responses within the microstructure and chemical composition at the nanoscale. The precise quantitative analysis of chemical composition remains a notable challenge in APT, primarily due to the influence of measurement conditions on compositional accuracy. In this study, we investigated the impact of laser pulse energy on the composition of β-TCP using APT, aiming for the most precise Ca:P ratio and consistent results across multiple analyses performed with different sets of analysis conditions and on two different instruments.</p>\",\"PeriodicalId\":18625,\"journal\":{\"name\":\"Microscopy and Microanalysis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-08-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microscopy and Microanalysis\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1093/mam/ozae077\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy and Microanalysis","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1093/mam/ozae077","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

β-磷酸三钙(β-TCP,Ca3(PO4)2)的生物相容性和吸收特性使其成为令人垂涎的骨移植替代品。然而,β-磷酸三钙与破骨细胞之间的生物相互作用的基本机制仍然难以捉摸。据推测,晶界处的成分可能会发生变化,并影响 β-TCP 的吸收特性。原子探针断层扫描(APT)提供了一种定量评估晶界成分的方法,从而促进了我们对微观结构和纳米尺度化学成分中生物反应的理解。对化学成分的精确定量分析仍然是 APT 的一个显著挑战,这主要是由于测量条件对成分精度的影响。在本研究中,我们利用 APT 研究了激光脉冲能量对 β-TCP 成分的影响,目的是获得最精确的 Ca:P 比率,并在两台不同仪器上使用不同的分析条件进行多次分析时获得一致的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimization of Parameters for Atom Probe Tomography Analysis of β-Tricalcium Phosphates.

The biocompatibility and resorption characteristics of β-tricalcium phosphate (β-TCP, Ca3(PO4)2) have made it a coveted alternative for bone grafts. However, the underlying mechanisms governing the biological interactions between β-tricalcium phosphate and osteoclasts remain elusive. It has been speculated that the composition at grain boundaries might vary and affect β-TCP resorption properties. Atom probe tomography (APT) offers a quantitative approach to assess the composition of the grain boundaries, and thus advance our comprehension of the biological responses within the microstructure and chemical composition at the nanoscale. The precise quantitative analysis of chemical composition remains a notable challenge in APT, primarily due to the influence of measurement conditions on compositional accuracy. In this study, we investigated the impact of laser pulse energy on the composition of β-TCP using APT, aiming for the most precise Ca:P ratio and consistent results across multiple analyses performed with different sets of analysis conditions and on two different instruments.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microscopy and Microanalysis
Microscopy and Microanalysis 工程技术-材料科学:综合
CiteScore
1.10
自引率
10.70%
发文量
1391
审稿时长
6 months
期刊介绍: Microscopy and Microanalysis publishes original research papers in the fields of microscopy, imaging, and compositional analysis. This distinguished international forum is intended for microscopists in both biology and materials science. The journal provides significant articles that describe new and existing techniques and instrumentation, as well as the applications of these to the imaging and analysis of microstructure. Microscopy and Microanalysis also includes review articles, letters to the editor, and book reviews.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信