{"title":"使用 810 和 980 nm 二极管激光进行第二阶段牙科种植手术后的温度升高和疼痛:临床试验。","authors":"Bahareh Hosseini Mehvar, Arash Azizi, Shirin Lavaf, Ardavan Etemadi, Ali Hassani","doi":"10.34172/jlms.2024.29","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> Many surgical procedures in a soft tissue are performed using diodes lasers. This study aimed to assess the temperature rise and pain following the use of 810 and 980 nm diode lasers for second-stage dental implant surgery. <b>Methods:</b> This clinical trial was conducted on 24 osseointegrated dental implants that were randomly divided into two groups of 810 nm and 980 nm diode lasers. The temperature rise in each group was measured right after uncovering by the laser and 15 minutes later by a thermocouple, compared with the baseline temperature of gingival tissue. The level of pain was also measured at 24 hours postoperatively by using a visual analog scale. Data were analyzed by ANOVA, Tukey's test, and <i>t</i> test (alpha=0.05). <b>Results:</b> Within-group comparisons by ANOVA showed a significant difference in tissue temperature between the three time points in both groups (<i>P</i><0.0001). Pairwise comparisons by Tukey's test showed that the temperature at baseline (<i>P</i><0.0001) and 15 seconds after uncovering was significantly lower than that immediately after uncovering in both groups (<i>P</i><0.0001). The mean tissue temperature and the mean pain score in the 980 nm laser group were significantly higher than the corresponding values in the 810 nm laser group (<i>P</i><0.05). <b>Conclusion:</b> According to the results, temperature rise in the use of the 980 nm laser was higher than the 810 nm laser. The use of 810 nm diode laser was associated with lower temperature rise and significantly lower pain score after 24 hours.</p>","PeriodicalId":16224,"journal":{"name":"Journal of lasers in medical sciences","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11345799/pdf/","citationCount":"0","resultStr":"{\"title\":\"Temperature Rise and Pain Following the Use of 810 and 980 nm Diode Lasers for Second-Stage Dental Implant Surgery: A Clinical Trial.\",\"authors\":\"Bahareh Hosseini Mehvar, Arash Azizi, Shirin Lavaf, Ardavan Etemadi, Ali Hassani\",\"doi\":\"10.34172/jlms.2024.29\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Introduction:</b> Many surgical procedures in a soft tissue are performed using diodes lasers. This study aimed to assess the temperature rise and pain following the use of 810 and 980 nm diode lasers for second-stage dental implant surgery. <b>Methods:</b> This clinical trial was conducted on 24 osseointegrated dental implants that were randomly divided into two groups of 810 nm and 980 nm diode lasers. The temperature rise in each group was measured right after uncovering by the laser and 15 minutes later by a thermocouple, compared with the baseline temperature of gingival tissue. The level of pain was also measured at 24 hours postoperatively by using a visual analog scale. Data were analyzed by ANOVA, Tukey's test, and <i>t</i> test (alpha=0.05). <b>Results:</b> Within-group comparisons by ANOVA showed a significant difference in tissue temperature between the three time points in both groups (<i>P</i><0.0001). Pairwise comparisons by Tukey's test showed that the temperature at baseline (<i>P</i><0.0001) and 15 seconds after uncovering was significantly lower than that immediately after uncovering in both groups (<i>P</i><0.0001). The mean tissue temperature and the mean pain score in the 980 nm laser group were significantly higher than the corresponding values in the 810 nm laser group (<i>P</i><0.05). <b>Conclusion:</b> According to the results, temperature rise in the use of the 980 nm laser was higher than the 810 nm laser. The use of 810 nm diode laser was associated with lower temperature rise and significantly lower pain score after 24 hours.</p>\",\"PeriodicalId\":16224,\"journal\":{\"name\":\"Journal of lasers in medical sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11345799/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of lasers in medical sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.34172/jlms.2024.29\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of lasers in medical sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/jlms.2024.29","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

简介许多软组织外科手术都使用二极管激光器。本研究旨在评估在第二阶段牙科种植手术中使用 810 和 980 纳米二极管激光器后的温升和疼痛情况。方法:这项临床试验针对 24 个骨结合牙科种植体,将其随机分为 810 纳米和 980 纳米二极管激光器两组。每组的温度升高情况都是在激光揭盖后和 15 分钟后用热电偶测量的,并与牙龈组织的基线温度进行比较。术后 24 小时,还使用视觉模拟量表测量了疼痛程度。数据分析采用方差分析、Tukey 检验和 t 检验(α=0.05)。结果:方差分析的组内比较显示,两组在三个时间点之间的组织温度差异显著(PPPPC结论:结果显示,使用 980 nm 激光时的温升高于 810 nm 激光。使用 810 纳米二极管激光的温升较低,24 小时后的疼痛评分也明显降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Temperature Rise and Pain Following the Use of 810 and 980 nm Diode Lasers for Second-Stage Dental Implant Surgery: A Clinical Trial.

Introduction: Many surgical procedures in a soft tissue are performed using diodes lasers. This study aimed to assess the temperature rise and pain following the use of 810 and 980 nm diode lasers for second-stage dental implant surgery. Methods: This clinical trial was conducted on 24 osseointegrated dental implants that were randomly divided into two groups of 810 nm and 980 nm diode lasers. The temperature rise in each group was measured right after uncovering by the laser and 15 minutes later by a thermocouple, compared with the baseline temperature of gingival tissue. The level of pain was also measured at 24 hours postoperatively by using a visual analog scale. Data were analyzed by ANOVA, Tukey's test, and t test (alpha=0.05). Results: Within-group comparisons by ANOVA showed a significant difference in tissue temperature between the three time points in both groups (P<0.0001). Pairwise comparisons by Tukey's test showed that the temperature at baseline (P<0.0001) and 15 seconds after uncovering was significantly lower than that immediately after uncovering in both groups (P<0.0001). The mean tissue temperature and the mean pain score in the 980 nm laser group were significantly higher than the corresponding values in the 810 nm laser group (P<0.05). Conclusion: According to the results, temperature rise in the use of the 980 nm laser was higher than the 810 nm laser. The use of 810 nm diode laser was associated with lower temperature rise and significantly lower pain score after 24 hours.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of lasers in medical sciences
Journal of lasers in medical sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
13.30%
发文量
24
期刊介绍: The "Journal of Lasers in Medical Sciences " is a scientific quarterly publication of the Laser Application in Medical Sciences Research Center, Shahid Beheshti University of Medical Sciences. This journal received a scientific and research rank from the national medical publication committee. This Journal accepts original papers, review articles, case reports, brief reports, case series, photo assays, letters to the editor, and commentaries in the field of laser, or light in any fields of medicine such as the following medical specialties: -Dermatology -General and Vascular Surgery -Oncology -Cardiology -Dentistry -Urology -Rehabilitation -Ophthalmology -Otorhinolaryngology -Gynecology & Obstetrics -Internal Medicine -Orthopedics -Neurosurgery -Radiology -Pain Medicine (Algology) -Basic Sciences (Stem cell, Cellular and Molecular application and physic)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信