William D.P. Fonseca , Rodolfo M. Perissinotto , Rafael F.L. Cerqueira , William Monte Verde , Marcelo S. Castro , Erick M. Franklin
{"title":"离心泵叶轮中的粒子图像测速仪:湍流与能量损失之间的关系","authors":"William D.P. Fonseca , Rodolfo M. Perissinotto , Rafael F.L. Cerqueira , William Monte Verde , Marcelo S. Castro , Erick M. Franklin","doi":"10.1016/j.flowmeasinst.2024.102675","DOIUrl":null,"url":null,"abstract":"<div><p>Turbulent flows play a dominant role in the operation of centrifugal pumps, which find widespread use in industrial settings and various aspects of human life. The dissipation rate of turbulent kinetic energy emerges as a key parameter within these devices, with its local values exerting a significant influence on centrifugal pump performance. Recent advances in particle image velocimetry (PIV) techniques have expanded the ability to analyze complex turbulent flows across a broad spectrum of scales. In this context, this paper aims to deepen our understanding of the turbulent flow field and its correlation with energy loss in centrifugal pump impellers. To achieve this, experiments were conducted using PIV on a transparent pump operating under different conditions. Statistics of the turbulent flow were then obtained from phase-ensemble averages of velocities, vorticity, turbulence production, and local dissipation of turbulent kinetic energy. To overcome the limited spatial resolution constraint of PIV, the large-eddy PIV (LES-PIV) method was employed to estimate the local dissipation rate. In this method, it is assumed that the motion of larger scales is measured by the PIV technique, while the smaller scales (unresolved scales) are modeled by a sub-grid scale model, calculated from the strain rate tensors obtained from the measured fields. Energy losses in the impeller were studied using two methodologies: (i) a conventional method based on power measurements, and (ii) an alternative approach based on the budget of turbulent kinetic energy. Our results reveal that turbulent loss caused by turbulence production is the main source of energy loss in the pump impeller, and it is particularly pronounced in low-flow operating conditions characterized by large-scale structures. On the other hand, in situations where flow rates exceed the best efficiency point (BEP) condition, the predominant flow structures are marked by small-scale features, mainly attributed to local dissipation of turbulence. Our findings clarify the characteristics of energy losses in centrifugal pump impellers and their relationship with the turbulent flow field, and, in addition, providing a methodology for calculating the local turbulent dissipation rate and its limitations when derived from PIV measurements.</p></div>","PeriodicalId":50440,"journal":{"name":"Flow Measurement and Instrumentation","volume":"99 ","pages":"Article 102675"},"PeriodicalIF":2.3000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Particle image velocimetry in the impeller of a centrifugal pump: Relationship between turbulent flow and energy loss\",\"authors\":\"William D.P. Fonseca , Rodolfo M. Perissinotto , Rafael F.L. Cerqueira , William Monte Verde , Marcelo S. Castro , Erick M. Franklin\",\"doi\":\"10.1016/j.flowmeasinst.2024.102675\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Turbulent flows play a dominant role in the operation of centrifugal pumps, which find widespread use in industrial settings and various aspects of human life. The dissipation rate of turbulent kinetic energy emerges as a key parameter within these devices, with its local values exerting a significant influence on centrifugal pump performance. Recent advances in particle image velocimetry (PIV) techniques have expanded the ability to analyze complex turbulent flows across a broad spectrum of scales. In this context, this paper aims to deepen our understanding of the turbulent flow field and its correlation with energy loss in centrifugal pump impellers. To achieve this, experiments were conducted using PIV on a transparent pump operating under different conditions. Statistics of the turbulent flow were then obtained from phase-ensemble averages of velocities, vorticity, turbulence production, and local dissipation of turbulent kinetic energy. To overcome the limited spatial resolution constraint of PIV, the large-eddy PIV (LES-PIV) method was employed to estimate the local dissipation rate. In this method, it is assumed that the motion of larger scales is measured by the PIV technique, while the smaller scales (unresolved scales) are modeled by a sub-grid scale model, calculated from the strain rate tensors obtained from the measured fields. Energy losses in the impeller were studied using two methodologies: (i) a conventional method based on power measurements, and (ii) an alternative approach based on the budget of turbulent kinetic energy. Our results reveal that turbulent loss caused by turbulence production is the main source of energy loss in the pump impeller, and it is particularly pronounced in low-flow operating conditions characterized by large-scale structures. On the other hand, in situations where flow rates exceed the best efficiency point (BEP) condition, the predominant flow structures are marked by small-scale features, mainly attributed to local dissipation of turbulence. Our findings clarify the characteristics of energy losses in centrifugal pump impellers and their relationship with the turbulent flow field, and, in addition, providing a methodology for calculating the local turbulent dissipation rate and its limitations when derived from PIV measurements.</p></div>\",\"PeriodicalId\":50440,\"journal\":{\"name\":\"Flow Measurement and Instrumentation\",\"volume\":\"99 \",\"pages\":\"Article 102675\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Flow Measurement and Instrumentation\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0955598624001559\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Flow Measurement and Instrumentation","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0955598624001559","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Particle image velocimetry in the impeller of a centrifugal pump: Relationship between turbulent flow and energy loss
Turbulent flows play a dominant role in the operation of centrifugal pumps, which find widespread use in industrial settings and various aspects of human life. The dissipation rate of turbulent kinetic energy emerges as a key parameter within these devices, with its local values exerting a significant influence on centrifugal pump performance. Recent advances in particle image velocimetry (PIV) techniques have expanded the ability to analyze complex turbulent flows across a broad spectrum of scales. In this context, this paper aims to deepen our understanding of the turbulent flow field and its correlation with energy loss in centrifugal pump impellers. To achieve this, experiments were conducted using PIV on a transparent pump operating under different conditions. Statistics of the turbulent flow were then obtained from phase-ensemble averages of velocities, vorticity, turbulence production, and local dissipation of turbulent kinetic energy. To overcome the limited spatial resolution constraint of PIV, the large-eddy PIV (LES-PIV) method was employed to estimate the local dissipation rate. In this method, it is assumed that the motion of larger scales is measured by the PIV technique, while the smaller scales (unresolved scales) are modeled by a sub-grid scale model, calculated from the strain rate tensors obtained from the measured fields. Energy losses in the impeller were studied using two methodologies: (i) a conventional method based on power measurements, and (ii) an alternative approach based on the budget of turbulent kinetic energy. Our results reveal that turbulent loss caused by turbulence production is the main source of energy loss in the pump impeller, and it is particularly pronounced in low-flow operating conditions characterized by large-scale structures. On the other hand, in situations where flow rates exceed the best efficiency point (BEP) condition, the predominant flow structures are marked by small-scale features, mainly attributed to local dissipation of turbulence. Our findings clarify the characteristics of energy losses in centrifugal pump impellers and their relationship with the turbulent flow field, and, in addition, providing a methodology for calculating the local turbulent dissipation rate and its limitations when derived from PIV measurements.
期刊介绍:
Flow Measurement and Instrumentation is dedicated to disseminating the latest research results on all aspects of flow measurement, in both closed conduits and open channels. The design of flow measurement systems involves a wide variety of multidisciplinary activities including modelling the flow sensor, the fluid flow and the sensor/fluid interactions through the use of computation techniques; the development of advanced transducer systems and their associated signal processing and the laboratory and field assessment of the overall system under ideal and disturbed conditions.
FMI is the essential forum for critical information exchange, and contributions are particularly encouraged in the following areas of interest:
Modelling: the application of mathematical and computational modelling to the interaction of fluid dynamics with flowmeters, including flowmeter behaviour, improved flowmeter design and installation problems. Application of CAD/CAE techniques to flowmeter modelling are eligible.
Design and development: the detailed design of the flowmeter head and/or signal processing aspects of novel flowmeters. Emphasis is given to papers identifying new sensor configurations, multisensor flow measurement systems, non-intrusive flow metering techniques and the application of microelectronic techniques in smart or intelligent systems.
Calibration techniques: including descriptions of new or existing calibration facilities and techniques, calibration data from different flowmeter types, and calibration intercomparison data from different laboratories.
Installation effect data: dealing with the effects of non-ideal flow conditions on flowmeters. Papers combining a theoretical understanding of flowmeter behaviour with experimental work are particularly welcome.