利用基于 CBCT 的虚拟模型对视神经管进行三维解剖分析。

IF 2.1 2区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Enno Lilienthal , Shih-Jan Chin , Reinhard E. Friedrich
{"title":"利用基于 CBCT 的虚拟模型对视神经管进行三维解剖分析。","authors":"Enno Lilienthal ,&nbsp;Shih-Jan Chin ,&nbsp;Reinhard E. Friedrich","doi":"10.1016/j.jcms.2024.03.031","DOIUrl":null,"url":null,"abstract":"<div><div>The optic nerve canal (ONC) is a fine skeletal structure that contains the optic nerve. However, it has not been thoroughly examined. This necessitates establishing a baseline knowledge of the geometrical and volumetric parameters of the ONC. The data of twenty patients who received a cone beam computed tomography examination were prepared using a voxel-based segmentation. The measurement was performed separately by two examiners on virtual skull models in stereolithography format in Geomagic Wrap®. The results showed that the volume of the ONC varied between 92.48 mm<sup>3</sup> and 162.7 mm<sup>3</sup> (M = 123.46 mm<sup>3</sup>, SD = 26.61 mm<sup>3</sup>). Sex-specific statistically significant differences in volume were detected only for the right side. The angle of the ONC to the skull base was independent of the diameter of the canal. Both the intrarater and interrater comparisons of the measurements showed high values of reproducibility of the results. This study showed that a virtual anatomical model provides a feasible and reliable method to investigate the ONC. The examination technique could have a wider range of application in anthropology and application in clinical medicine. Advances in the automation of radiological diagnostics and the digital analysis of X-ray images could help to reduce examination times.</div></div>","PeriodicalId":54851,"journal":{"name":"Journal of Cranio-Maxillofacial Surgery","volume":"52 11","pages":"Pages 1219-1227"},"PeriodicalIF":2.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Three-dimensional anatomical analysis of the optic nerve canal with virtual model based on CBCT\",\"authors\":\"Enno Lilienthal ,&nbsp;Shih-Jan Chin ,&nbsp;Reinhard E. Friedrich\",\"doi\":\"10.1016/j.jcms.2024.03.031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The optic nerve canal (ONC) is a fine skeletal structure that contains the optic nerve. However, it has not been thoroughly examined. This necessitates establishing a baseline knowledge of the geometrical and volumetric parameters of the ONC. The data of twenty patients who received a cone beam computed tomography examination were prepared using a voxel-based segmentation. The measurement was performed separately by two examiners on virtual skull models in stereolithography format in Geomagic Wrap®. The results showed that the volume of the ONC varied between 92.48 mm<sup>3</sup> and 162.7 mm<sup>3</sup> (M = 123.46 mm<sup>3</sup>, SD = 26.61 mm<sup>3</sup>). Sex-specific statistically significant differences in volume were detected only for the right side. The angle of the ONC to the skull base was independent of the diameter of the canal. Both the intrarater and interrater comparisons of the measurements showed high values of reproducibility of the results. This study showed that a virtual anatomical model provides a feasible and reliable method to investigate the ONC. The examination technique could have a wider range of application in anthropology and application in clinical medicine. Advances in the automation of radiological diagnostics and the digital analysis of X-ray images could help to reduce examination times.</div></div>\",\"PeriodicalId\":54851,\"journal\":{\"name\":\"Journal of Cranio-Maxillofacial Surgery\",\"volume\":\"52 11\",\"pages\":\"Pages 1219-1227\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cranio-Maxillofacial Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1010518224001008\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cranio-Maxillofacial Surgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1010518224001008","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

视神经管(ONC)是一种包含视神经的精细骨骼结构。然而,对它的研究还不够深入。因此,有必要对视神经管的几何和容积参数进行基本了解。我们使用基于体素的分割方法准备了 20 名接受锥形束计算机断层扫描检查的患者的数据。测量由两名检查员分别在 Geomagic Wrap® 立体光刻格式的虚拟头骨模型上进行。结果显示,ONC 的体积介于 92.48 mm3 和 162.7 mm3 之间(M = 123.46 mm3,SD = 26.61 mm3)。只有右侧的体积存在显著的性别差异。ONC 与颅底的夹角与耳道直径无关。测量结果的内部和内部比较均显示结果具有很高的可重复性。这项研究表明,虚拟解剖模型提供了一种可行而可靠的方法来检查颅内孔。该检查技术可在人类学和临床医学中得到更广泛的应用。放射诊断自动化和 X 射线图像数字分析的进步有助于缩短检查时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Three-dimensional anatomical analysis of the optic nerve canal with virtual model based on CBCT
The optic nerve canal (ONC) is a fine skeletal structure that contains the optic nerve. However, it has not been thoroughly examined. This necessitates establishing a baseline knowledge of the geometrical and volumetric parameters of the ONC. The data of twenty patients who received a cone beam computed tomography examination were prepared using a voxel-based segmentation. The measurement was performed separately by two examiners on virtual skull models in stereolithography format in Geomagic Wrap®. The results showed that the volume of the ONC varied between 92.48 mm3 and 162.7 mm3 (M = 123.46 mm3, SD = 26.61 mm3). Sex-specific statistically significant differences in volume were detected only for the right side. The angle of the ONC to the skull base was independent of the diameter of the canal. Both the intrarater and interrater comparisons of the measurements showed high values of reproducibility of the results. This study showed that a virtual anatomical model provides a feasible and reliable method to investigate the ONC. The examination technique could have a wider range of application in anthropology and application in clinical medicine. Advances in the automation of radiological diagnostics and the digital analysis of X-ray images could help to reduce examination times.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.20
自引率
22.60%
发文量
117
审稿时长
70 days
期刊介绍: The Journal of Cranio-Maxillofacial Surgery publishes articles covering all aspects of surgery of the head, face and jaw. Specific topics covered recently have included: • Distraction osteogenesis • Synthetic bone substitutes • Fibroblast growth factors • Fetal wound healing • Skull base surgery • Computer-assisted surgery • Vascularized bone grafts
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信