T1 加权乳腺 MRI 的纵向配准:配准算法(FLIRE)及临床应用。

IF 2.1 4区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Michelle W. Tong , Hon J. Yu , Maren M. Sjaastad Andreassen , Stephane Loubrie , Ana E. Rodríguez-Soto , Tyler M. Seibert , Rebecca Rakow-Penner , Anders M. Dale
{"title":"T1 加权乳腺 MRI 的纵向配准:配准算法(FLIRE)及临床应用。","authors":"Michelle W. Tong ,&nbsp;Hon J. Yu ,&nbsp;Maren M. Sjaastad Andreassen ,&nbsp;Stephane Loubrie ,&nbsp;Ana E. Rodríguez-Soto ,&nbsp;Tyler M. Seibert ,&nbsp;Rebecca Rakow-Penner ,&nbsp;Anders M. Dale","doi":"10.1016/j.mri.2024.110222","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>MRI is commonly used to aid breast cancer diagnosis and treatment evaluation. For patients with breast cancer, neoadjuvant chemotherapy aims to reduce the tumor size and extent of surgery necessary. The current clinical standard to measure breast tumor response on MRI uses the longest tumor diameter. Radiologists also account for other tissue properties including tumor contrast or pharmacokinetics in their assessment. Accurate longitudinal image registration of breast tissue is critical to properly compare response to treatment at different timepoints.</p></div><div><h3>Methods</h3><p>In this study, a deformable Fast Longitudinal Image Registration (FLIRE) algorithm was optimized for breast tissue. FLIRE was then compared to the publicly available software packages with high accuracy (DRAMMS) and fast runtime (Elastix). Patients included in the study received longitudinal T<sub>1</sub><sub>-</sub>weighted MRI without fat saturation at two to six timepoints as part of asymptomatic screening (<em>n</em> = 27) or throughout neoadjuvant chemotherapy treatment (<em>n</em> = 32). T<sub>1</sub><sub>-</sub>weighted images were registered to the first timepoint with each algorithm.</p></div><div><h3>Results</h3><p>Alignment and runtime performance were compared using two-way repeated measure ANOVAs (<em>P</em> &lt; 0.05). Across all patients, Pearson's correlation coefficient across the entire image volume was slightly higher with statistical significance and had less variance for FLIRE (0.98 ± 0.01 stdev) compared to DRAMMS (0.97 ± 0.03 stdev) and Elastix (0.95 ± 0.03 stdev). Additionally, FLIRE runtime (10.0 mins) was 9.0 times faster than DRAMMS (89.6 mins) and 1.5 times faster than Elastix (14.5 mins) on a Linux workstation.</p></div><div><h3>Conclusion</h3><p>FLIRE demonstrates promise for time-sensitive clinical applications due to its accuracy, robustness across patients and timepoints, and speed.</p></div>","PeriodicalId":18165,"journal":{"name":"Magnetic resonance imaging","volume":"113 ","pages":"Article 110222"},"PeriodicalIF":2.1000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0730725X24002030/pdfft?md5=3a8823f570ed73e6dfad0e0fd6b7ec98&pid=1-s2.0-S0730725X24002030-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Longitudinal registration of T1-weighted breast MRI: A registration algorithm (FLIRE) and clinical application\",\"authors\":\"Michelle W. Tong ,&nbsp;Hon J. Yu ,&nbsp;Maren M. Sjaastad Andreassen ,&nbsp;Stephane Loubrie ,&nbsp;Ana E. Rodríguez-Soto ,&nbsp;Tyler M. Seibert ,&nbsp;Rebecca Rakow-Penner ,&nbsp;Anders M. Dale\",\"doi\":\"10.1016/j.mri.2024.110222\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><p>MRI is commonly used to aid breast cancer diagnosis and treatment evaluation. For patients with breast cancer, neoadjuvant chemotherapy aims to reduce the tumor size and extent of surgery necessary. The current clinical standard to measure breast tumor response on MRI uses the longest tumor diameter. Radiologists also account for other tissue properties including tumor contrast or pharmacokinetics in their assessment. Accurate longitudinal image registration of breast tissue is critical to properly compare response to treatment at different timepoints.</p></div><div><h3>Methods</h3><p>In this study, a deformable Fast Longitudinal Image Registration (FLIRE) algorithm was optimized for breast tissue. FLIRE was then compared to the publicly available software packages with high accuracy (DRAMMS) and fast runtime (Elastix). Patients included in the study received longitudinal T<sub>1</sub><sub>-</sub>weighted MRI without fat saturation at two to six timepoints as part of asymptomatic screening (<em>n</em> = 27) or throughout neoadjuvant chemotherapy treatment (<em>n</em> = 32). T<sub>1</sub><sub>-</sub>weighted images were registered to the first timepoint with each algorithm.</p></div><div><h3>Results</h3><p>Alignment and runtime performance were compared using two-way repeated measure ANOVAs (<em>P</em> &lt; 0.05). Across all patients, Pearson's correlation coefficient across the entire image volume was slightly higher with statistical significance and had less variance for FLIRE (0.98 ± 0.01 stdev) compared to DRAMMS (0.97 ± 0.03 stdev) and Elastix (0.95 ± 0.03 stdev). Additionally, FLIRE runtime (10.0 mins) was 9.0 times faster than DRAMMS (89.6 mins) and 1.5 times faster than Elastix (14.5 mins) on a Linux workstation.</p></div><div><h3>Conclusion</h3><p>FLIRE demonstrates promise for time-sensitive clinical applications due to its accuracy, robustness across patients and timepoints, and speed.</p></div>\",\"PeriodicalId\":18165,\"journal\":{\"name\":\"Magnetic resonance imaging\",\"volume\":\"113 \",\"pages\":\"Article 110222\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0730725X24002030/pdfft?md5=3a8823f570ed73e6dfad0e0fd6b7ec98&pid=1-s2.0-S0730725X24002030-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic resonance imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0730725X24002030\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance imaging","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0730725X24002030","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:磁共振成像通常用于辅助乳腺癌诊断和治疗评估。对于乳腺癌患者来说,新辅助化疗的目的是缩小肿瘤大小,减少手术范围。目前在核磁共振成像上测量乳腺肿瘤反应的临床标准是使用最长的肿瘤直径。放射医师在评估时还会考虑其他组织特性,包括肿瘤对比度/药代动力学。准确的乳腺组织纵向图像配准对于正确比较不同时间点的治疗反应至关重要:本研究针对乳腺组织优化了可变形快速纵向图像配准(FLIRE)算法。然后将 FLIRE 与高精度(DRAMMS)和快速运行(Elastix)的公开软件包进行比较。作为无症状筛查(27 例)或整个新辅助化疗过程(32 例)的一部分,参与研究的患者在 2 到 6 个时间点接受了无脂肪饱和的纵向 T1 加权磁共振成像。每种算法的 T1 加权图像均登记到第一个时间点:结果:使用双向重复测量方差分析比较了对准和运行时间性能(PFLIRE 具有准确性、跨患者和时间点的鲁棒性以及速度快等优点,有望用于时间敏感型临床应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Longitudinal registration of T1-weighted breast MRI: A registration algorithm (FLIRE) and clinical application

Purpose

MRI is commonly used to aid breast cancer diagnosis and treatment evaluation. For patients with breast cancer, neoadjuvant chemotherapy aims to reduce the tumor size and extent of surgery necessary. The current clinical standard to measure breast tumor response on MRI uses the longest tumor diameter. Radiologists also account for other tissue properties including tumor contrast or pharmacokinetics in their assessment. Accurate longitudinal image registration of breast tissue is critical to properly compare response to treatment at different timepoints.

Methods

In this study, a deformable Fast Longitudinal Image Registration (FLIRE) algorithm was optimized for breast tissue. FLIRE was then compared to the publicly available software packages with high accuracy (DRAMMS) and fast runtime (Elastix). Patients included in the study received longitudinal T1-weighted MRI without fat saturation at two to six timepoints as part of asymptomatic screening (n = 27) or throughout neoadjuvant chemotherapy treatment (n = 32). T1-weighted images were registered to the first timepoint with each algorithm.

Results

Alignment and runtime performance were compared using two-way repeated measure ANOVAs (P < 0.05). Across all patients, Pearson's correlation coefficient across the entire image volume was slightly higher with statistical significance and had less variance for FLIRE (0.98 ± 0.01 stdev) compared to DRAMMS (0.97 ± 0.03 stdev) and Elastix (0.95 ± 0.03 stdev). Additionally, FLIRE runtime (10.0 mins) was 9.0 times faster than DRAMMS (89.6 mins) and 1.5 times faster than Elastix (14.5 mins) on a Linux workstation.

Conclusion

FLIRE demonstrates promise for time-sensitive clinical applications due to its accuracy, robustness across patients and timepoints, and speed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Magnetic resonance imaging
Magnetic resonance imaging 医学-核医学
CiteScore
4.70
自引率
4.00%
发文量
194
审稿时长
83 days
期刊介绍: Magnetic Resonance Imaging (MRI) is the first international multidisciplinary journal encompassing physical, life, and clinical science investigations as they relate to the development and use of magnetic resonance imaging. MRI is dedicated to both basic research, technological innovation and applications, providing a single forum for communication among radiologists, physicists, chemists, biochemists, biologists, engineers, internists, pathologists, physiologists, computer scientists, and mathematicians.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信