全踝关节成形术模板制作:术前计算机模板与术中组件选择高度相关。

IF 1.3 4区 医学 Q2 Medicine
Journal of Foot & Ankle Surgery Pub Date : 2025-01-01 Epub Date: 2024-08-19 DOI:10.1053/j.jfas.2024.08.006
Robert J Teasdall, Bryanna D Vesely, Taylor R Wood, Jennifer A Kipp, Kyle A Lynch, Samuel Rosas, Aaron T Scott
{"title":"全踝关节成形术模板制作:术前计算机模板与术中组件选择高度相关。","authors":"Robert J Teasdall, Bryanna D Vesely, Taylor R Wood, Jennifer A Kipp, Kyle A Lynch, Samuel Rosas, Aaron T Scott","doi":"10.1053/j.jfas.2024.08.006","DOIUrl":null,"url":null,"abstract":"<p><p>Proper alignment and sizing are critical to the performance of a successful total ankle arthroplasty. While it is common practice in preoperative planning prior to total knee and total hip arthroplasty, preoperative computer templating has not been well established in the setting of total ankle arthroplasty. A retrospective review of all total ankle arthroplasties performed during a 10-year period by a single fellowship-trained orthopaedic surgeon was conducted. Computer templating was utilized for all preoperative Anterior to Posterior (AP) and lateral standing radiographs, and templated component sizes were compared to the operative reports and postoperative radiographs to determine the precision of the available templates. Statistical analysis was performed with Interclass Correlation Coefficients (ICC) and descriptive statistical tests. Seventy patients with a mean age of 64.8 years (range, 48-87) and mean BMI of 30.34 (range, 19.1-55.6) were included. The ICC demonstrated that both the AP (ICC 0.80 - 95% CI 0.679-0.876) and lateral (ICC 0.786 - 95% CI 0.655-0.867) radiographs provided accurate tibial total ankle arthroplasty component templating. Similarly, the AP (ICC 0.842 - 95% CI 0.745-0.902) and lateral (ICC 0.809 - 95% CI 0.692-0.881) radiographs provided accurate talar templating. No differences were observed when comparing AP to lateral radiographs in percentage of correct component templating: tibial AP 61.4% vs lateral 58.6%, p = .119 and talar component AP 57.1% vs lateral 45.7%, p = .176. These study findings demonstrate that preoperative templating for total ankle arthroplasties is accurate in determining appropriate implant sizing. Accurate templating is an absolute necessity for future templating studies.</p>","PeriodicalId":50191,"journal":{"name":"Journal of Foot & Ankle Surgery","volume":" ","pages":"21-24"},"PeriodicalIF":1.3000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Total Ankle Arthroplasty Templating: Preoperative Computer Templating Correlates Highly with Intraoperative Component Selection.\",\"authors\":\"Robert J Teasdall, Bryanna D Vesely, Taylor R Wood, Jennifer A Kipp, Kyle A Lynch, Samuel Rosas, Aaron T Scott\",\"doi\":\"10.1053/j.jfas.2024.08.006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Proper alignment and sizing are critical to the performance of a successful total ankle arthroplasty. While it is common practice in preoperative planning prior to total knee and total hip arthroplasty, preoperative computer templating has not been well established in the setting of total ankle arthroplasty. A retrospective review of all total ankle arthroplasties performed during a 10-year period by a single fellowship-trained orthopaedic surgeon was conducted. Computer templating was utilized for all preoperative Anterior to Posterior (AP) and lateral standing radiographs, and templated component sizes were compared to the operative reports and postoperative radiographs to determine the precision of the available templates. Statistical analysis was performed with Interclass Correlation Coefficients (ICC) and descriptive statistical tests. Seventy patients with a mean age of 64.8 years (range, 48-87) and mean BMI of 30.34 (range, 19.1-55.6) were included. The ICC demonstrated that both the AP (ICC 0.80 - 95% CI 0.679-0.876) and lateral (ICC 0.786 - 95% CI 0.655-0.867) radiographs provided accurate tibial total ankle arthroplasty component templating. Similarly, the AP (ICC 0.842 - 95% CI 0.745-0.902) and lateral (ICC 0.809 - 95% CI 0.692-0.881) radiographs provided accurate talar templating. No differences were observed when comparing AP to lateral radiographs in percentage of correct component templating: tibial AP 61.4% vs lateral 58.6%, p = .119 and talar component AP 57.1% vs lateral 45.7%, p = .176. These study findings demonstrate that preoperative templating for total ankle arthroplasties is accurate in determining appropriate implant sizing. Accurate templating is an absolute necessity for future templating studies.</p>\",\"PeriodicalId\":50191,\"journal\":{\"name\":\"Journal of Foot & Ankle Surgery\",\"volume\":\" \",\"pages\":\"21-24\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Foot & Ankle Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1053/j.jfas.2024.08.006\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Foot & Ankle Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1053/j.jfas.2024.08.006","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/19 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

正确的对位和尺寸是成功实施全踝关节置换术的关键。虽然在全膝关节和全髋关节置换术前进行术前规划是常见的做法,但在全踝关节置换术中,术前计算机模板还没有得到很好的应用。我们对一位接受过研究培训的骨科外科医生在 10 年内完成的所有全踝关节置换术进行了回顾性研究。所有术前 AP 和侧方立位 X 光片均采用计算机模板,将模板组件尺寸与手术报告和术后 X 光片进行比较,以确定可用模板的精确度。统计分析采用类间相关系数(ICC)和描述性统计测试。纳入的 70 名患者的平均年龄为 64.8 岁(范围在 48-87 岁之间),平均体重指数为 30.34(范围在 19.1-55.6 之间)。类间相关系数(Interclass Correlation Coefficient)表明,AP(ICC 0.80 - 95% CI 0.679-0.876)和侧位(ICC 0.786 - 95% CI 0.655-0.867)X 光片均可提供准确的胫骨全踝关节置换组件模板。同样,AP(ICC 0.842 - 95% CI 0.745-0.902)和侧位(ICC 0.809 - 95% CI 0.692-0.881)X 光片可提供准确的距骨模板。胫骨AP片61.4%对侧位片58.6%,P=0.119;距骨组件前后位片57.1%对侧位片45.7%,P=0.176。这些研究结果表明,全踝关节置换术的术前模板在确定适当的植入物尺寸方面是准确的。未来的模板研究绝对需要准确的模板。临床证据级别:III.
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Total Ankle Arthroplasty Templating: Preoperative Computer Templating Correlates Highly with Intraoperative Component Selection.

Proper alignment and sizing are critical to the performance of a successful total ankle arthroplasty. While it is common practice in preoperative planning prior to total knee and total hip arthroplasty, preoperative computer templating has not been well established in the setting of total ankle arthroplasty. A retrospective review of all total ankle arthroplasties performed during a 10-year period by a single fellowship-trained orthopaedic surgeon was conducted. Computer templating was utilized for all preoperative Anterior to Posterior (AP) and lateral standing radiographs, and templated component sizes were compared to the operative reports and postoperative radiographs to determine the precision of the available templates. Statistical analysis was performed with Interclass Correlation Coefficients (ICC) and descriptive statistical tests. Seventy patients with a mean age of 64.8 years (range, 48-87) and mean BMI of 30.34 (range, 19.1-55.6) were included. The ICC demonstrated that both the AP (ICC 0.80 - 95% CI 0.679-0.876) and lateral (ICC 0.786 - 95% CI 0.655-0.867) radiographs provided accurate tibial total ankle arthroplasty component templating. Similarly, the AP (ICC 0.842 - 95% CI 0.745-0.902) and lateral (ICC 0.809 - 95% CI 0.692-0.881) radiographs provided accurate talar templating. No differences were observed when comparing AP to lateral radiographs in percentage of correct component templating: tibial AP 61.4% vs lateral 58.6%, p = .119 and talar component AP 57.1% vs lateral 45.7%, p = .176. These study findings demonstrate that preoperative templating for total ankle arthroplasties is accurate in determining appropriate implant sizing. Accurate templating is an absolute necessity for future templating studies.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Foot & Ankle Surgery
Journal of Foot & Ankle Surgery ORTHOPEDICS-SURGERY
CiteScore
2.30
自引率
7.70%
发文量
234
审稿时长
29.8 weeks
期刊介绍: The Journal of Foot & Ankle Surgery is the leading source for original, clinically-focused articles on the surgical and medical management of the foot and ankle. Each bi-monthly, peer-reviewed issue addresses relevant topics to the profession, such as: adult reconstruction of the forefoot; adult reconstruction of the hindfoot and ankle; diabetes; medicine/rheumatology; pediatrics; research; sports medicine; trauma; and tumors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信