基于碳纳米形式的透析纳米复合膜可抑制血浆蛋白吸附。

IF 1.4 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Dominika Wójtowicz, Roksana Kurpanik, Dominika Nguyen Ngoc, Joanna Wessley-Szponder, Ewa Stodolak-Zych
{"title":"基于碳纳米形式的透析纳米复合膜可抑制血浆蛋白吸附。","authors":"Dominika Wójtowicz, Roksana Kurpanik, Dominika Nguyen Ngoc, Joanna Wessley-Szponder, Ewa Stodolak-Zych","doi":"10.1177/03913988241269440","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Protein adsorption on medical devices in contact with blood is a significant issue during renal replacement therapy. Main forces determining fouling are the electrostatic interactions between membrane and charged protein, but the dialysis membrane surface charges can be adjusted by modifying the polymer matrix to decrease the blood plasma protein adsorption.</p><p><strong>Methods: </strong>In this study, polysulfone membranes (PSU) were modified by incorporation of carbon nanoparticles such as: multiwall carbon nanotubes (2 wt.% MWCNT), graphene oxide (1 wt.% GO), and graphite (5 wt.% GR) during manufacturing process (nonsolvent-induced phase separation, NIPS). The PSU flat sheet membrane was the reference sample.</p><p><strong>Results: </strong>Observed morphology of nanocomposite membranes was similar (SEM imaging); all of them had finger-like pore structure with unimodal distribution of pore size and similar skin-to-support ratio (1:3). The carbon nanoadditives also influenced the surface wettability: hydrophobicity and surface free energy of membranes increased (polar components of energy were reduced, while the dispersive components were increased).</p><p><strong>Conclusion: </strong>The surface charge of nanocomposite membranes increased, when the polymer matrix has been modified with CNT or GR. This significantly affects the adsorption of proteins such as chicken (CSA) and bovine serum albumin (BSA) and reduces blood clotting on the membrane.</p>","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dialysis nanocomposite membranes based on carbon nanoforms inhibiting blood plasma protein adsorption.\",\"authors\":\"Dominika Wójtowicz, Roksana Kurpanik, Dominika Nguyen Ngoc, Joanna Wessley-Szponder, Ewa Stodolak-Zych\",\"doi\":\"10.1177/03913988241269440\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Protein adsorption on medical devices in contact with blood is a significant issue during renal replacement therapy. Main forces determining fouling are the electrostatic interactions between membrane and charged protein, but the dialysis membrane surface charges can be adjusted by modifying the polymer matrix to decrease the blood plasma protein adsorption.</p><p><strong>Methods: </strong>In this study, polysulfone membranes (PSU) were modified by incorporation of carbon nanoparticles such as: multiwall carbon nanotubes (2 wt.% MWCNT), graphene oxide (1 wt.% GO), and graphite (5 wt.% GR) during manufacturing process (nonsolvent-induced phase separation, NIPS). The PSU flat sheet membrane was the reference sample.</p><p><strong>Results: </strong>Observed morphology of nanocomposite membranes was similar (SEM imaging); all of them had finger-like pore structure with unimodal distribution of pore size and similar skin-to-support ratio (1:3). The carbon nanoadditives also influenced the surface wettability: hydrophobicity and surface free energy of membranes increased (polar components of energy were reduced, while the dispersive components were increased).</p><p><strong>Conclusion: </strong>The surface charge of nanocomposite membranes increased, when the polymer matrix has been modified with CNT or GR. This significantly affects the adsorption of proteins such as chicken (CSA) and bovine serum albumin (BSA) and reduces blood clotting on the membrane.</p>\",\"PeriodicalId\":13932,\"journal\":{\"name\":\"International Journal of Artificial Organs\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/03913988241269440\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988241269440","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:蛋白质吸附在与血液接触的医疗设备上是肾脏替代治疗过程中的一个重要问题。决定污垢产生的主要因素是膜与带电蛋白质之间的静电相互作用,但透析膜表面的电荷可通过改性聚合物基质来调整,以减少血浆蛋白质的吸附:本研究在聚砜膜(PSU)的制造过程中加入了碳纳米颗粒,如:多壁碳纳米管(2 wt.% MWCNT)、氧化石墨烯(1 wt.% GO)和石墨(5 wt.% GR)(非溶剂诱导相分离,NIPS)。PSU 平板膜为参考样品:观察到的纳米复合膜形态相似(扫描电子显微镜成像);所有纳米复合膜都具有指状孔隙结构,孔隙大小呈单峰分布,表皮与支撑物的比例相似(1:3)。碳纳米添加剂还影响了表面润湿性:膜的疏水性和表面自由能增加(能量的极性成分减少,而分散成分增加):结论:用 CNT 或 GR 对聚合物基质进行改性后,纳米复合膜的表面电荷增加。结论:用 CNT 或 GR 对聚合物基质进行改性后,纳米复合膜的表面电荷增加,这极大地影响了膜对鸡肉(CSA)和牛血清白蛋白(BSA)等蛋白质的吸附,并减少了膜上的血液凝结。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dialysis nanocomposite membranes based on carbon nanoforms inhibiting blood plasma protein adsorption.

Background: Protein adsorption on medical devices in contact with blood is a significant issue during renal replacement therapy. Main forces determining fouling are the electrostatic interactions between membrane and charged protein, but the dialysis membrane surface charges can be adjusted by modifying the polymer matrix to decrease the blood plasma protein adsorption.

Methods: In this study, polysulfone membranes (PSU) were modified by incorporation of carbon nanoparticles such as: multiwall carbon nanotubes (2 wt.% MWCNT), graphene oxide (1 wt.% GO), and graphite (5 wt.% GR) during manufacturing process (nonsolvent-induced phase separation, NIPS). The PSU flat sheet membrane was the reference sample.

Results: Observed morphology of nanocomposite membranes was similar (SEM imaging); all of them had finger-like pore structure with unimodal distribution of pore size and similar skin-to-support ratio (1:3). The carbon nanoadditives also influenced the surface wettability: hydrophobicity and surface free energy of membranes increased (polar components of energy were reduced, while the dispersive components were increased).

Conclusion: The surface charge of nanocomposite membranes increased, when the polymer matrix has been modified with CNT or GR. This significantly affects the adsorption of proteins such as chicken (CSA) and bovine serum albumin (BSA) and reduces blood clotting on the membrane.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Artificial Organs
International Journal of Artificial Organs 医学-工程:生物医学
CiteScore
3.40
自引率
5.90%
发文量
92
审稿时长
3 months
期刊介绍: The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信