后腰椎椎体间融合术获得良好局部前凸角度的新技术:前路释放后腰椎椎体间融合术。

IF 2.3 Q2 ORTHOPEDICS
Asian Spine Journal Pub Date : 2024-10-01 Epub Date: 2024-08-21 DOI:10.31616/asj.2024.0131
Daisuke Inoue, Hiroaki Matsumori, Hideki Shigematsu, Yurito Ueda, Toshiya Morita, Sachiko Kawasaki, Masaki Ikejiri, Yasuhito Tanaka
{"title":"后腰椎椎体间融合术获得良好局部前凸角度的新技术:前路释放后腰椎椎体间融合术。","authors":"Daisuke Inoue, Hiroaki Matsumori, Hideki Shigematsu, Yurito Ueda, Toshiya Morita, Sachiko Kawasaki, Masaki Ikejiri, Yasuhito Tanaka","doi":"10.31616/asj.2024.0131","DOIUrl":null,"url":null,"abstract":"<p><p>Herein, we describe a novel posterior lumbar interbody fusion (PLIF) technique with annulus fibrosus (AF) release and the use of expandable cages (called \"anterior-release PLIF\" [ARPLIF]). In this technique, posterior column osteotomy (PCO) and AF release provide excellent intervertebral mobility. AF release involves circumferentially peeling off the AF above or below the endplate between the fixed vertebrae under radiographic guidance without cutting the AF and anterior longitudinal ligament. Subsequently, high-angle variable-angle expandable cages are used to simultaneously expand both sides before inserting the percutaneous pedicle screws and correcting to achieve good local lumbar lordosis. PCO and AF release achieve excellent intervertebral mobility. Intervertebral mobility and simultaneous expansion of both cages disperse the force on the endplates, reducing cage subsidence, and the high-angle cages facilitate high intervertebral angle creation. The novel ARPLIF intervertebral manipulation technique can promote good local lumbar lordosis formation.</p>","PeriodicalId":8555,"journal":{"name":"Asian Spine Journal","volume":" ","pages":"706-711"},"PeriodicalIF":2.3000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11538811/pdf/","citationCount":"0","resultStr":"{\"title\":\"A novel technique for posterior lumbar interbody fusion to obtain a good local lordosis angle: anterior-release posterior lumbar interbody fusion.\",\"authors\":\"Daisuke Inoue, Hiroaki Matsumori, Hideki Shigematsu, Yurito Ueda, Toshiya Morita, Sachiko Kawasaki, Masaki Ikejiri, Yasuhito Tanaka\",\"doi\":\"10.31616/asj.2024.0131\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Herein, we describe a novel posterior lumbar interbody fusion (PLIF) technique with annulus fibrosus (AF) release and the use of expandable cages (called \\\"anterior-release PLIF\\\" [ARPLIF]). In this technique, posterior column osteotomy (PCO) and AF release provide excellent intervertebral mobility. AF release involves circumferentially peeling off the AF above or below the endplate between the fixed vertebrae under radiographic guidance without cutting the AF and anterior longitudinal ligament. Subsequently, high-angle variable-angle expandable cages are used to simultaneously expand both sides before inserting the percutaneous pedicle screws and correcting to achieve good local lumbar lordosis. PCO and AF release achieve excellent intervertebral mobility. Intervertebral mobility and simultaneous expansion of both cages disperse the force on the endplates, reducing cage subsidence, and the high-angle cages facilitate high intervertebral angle creation. The novel ARPLIF intervertebral manipulation technique can promote good local lumbar lordosis formation.</p>\",\"PeriodicalId\":8555,\"journal\":{\"name\":\"Asian Spine Journal\",\"volume\":\" \",\"pages\":\"706-711\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11538811/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Spine Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31616/asj.2024.0131\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Spine Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31616/asj.2024.0131","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

在本文中,我们介绍了一种新型的后路腰椎椎体间融合术(PLIF)技术,该技术具有纤维环松解功能,并使用可扩张的笼架(称为 "前路松解 PLIF"[ARPLIF])。在这种技术中,后柱截骨术(PCO)和纤维环松解术提供了良好的椎体间活动度。AF松解术是在X光片引导下,在固定椎体之间的终板上方或下方环绕剥离AF,而不切断AF和前纵韧带。随后,在插入经皮椎弓根螺钉并进行矫正以达到良好的局部腰椎前凸之前,使用高角度可变角度扩张笼同时扩张两侧椎体。PCO 和 AF 释放术实现了良好的椎间活动度。椎间活动度和两侧椎弓根的同时扩张分散了对终板的作用力,减少了椎弓根的下沉,高角度椎弓根有利于创造高椎间角。新颖的 ARPLIF 椎间操作技术可促进良好的局部腰椎前凸形成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel technique for posterior lumbar interbody fusion to obtain a good local lordosis angle: anterior-release posterior lumbar interbody fusion.

Herein, we describe a novel posterior lumbar interbody fusion (PLIF) technique with annulus fibrosus (AF) release and the use of expandable cages (called "anterior-release PLIF" [ARPLIF]). In this technique, posterior column osteotomy (PCO) and AF release provide excellent intervertebral mobility. AF release involves circumferentially peeling off the AF above or below the endplate between the fixed vertebrae under radiographic guidance without cutting the AF and anterior longitudinal ligament. Subsequently, high-angle variable-angle expandable cages are used to simultaneously expand both sides before inserting the percutaneous pedicle screws and correcting to achieve good local lumbar lordosis. PCO and AF release achieve excellent intervertebral mobility. Intervertebral mobility and simultaneous expansion of both cages disperse the force on the endplates, reducing cage subsidence, and the high-angle cages facilitate high intervertebral angle creation. The novel ARPLIF intervertebral manipulation technique can promote good local lumbar lordosis formation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Asian Spine Journal
Asian Spine Journal ORTHOPEDICS-
CiteScore
5.10
自引率
4.30%
发文量
108
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信