血压变异性评估:血压测量方法的特点和比较。

IF 4.3 2区 医学 Q1 PERIPHERAL VASCULAR DISEASE
Keisuke Narita, Daichi Shimbo, Kazuomi Kario
{"title":"血压变异性评估:血压测量方法的特点和比较。","authors":"Keisuke Narita, Daichi Shimbo, Kazuomi Kario","doi":"10.1038/s41440-024-01844-y","DOIUrl":null,"url":null,"abstract":"<p><p>Previous studies have reported that blood pressure variability (BPV) is associated with the risk of cardiovascular events independent of blood pressure (BP) levels. While there is little evidence from intervention trials examining whether suppressing BPV is useful in preventing cardiovascular disease, it is suggested that detection of abnormally elevated BPV may be useful in reducing cardiovascular events adding by complementing management of appropriate BP levels. Cuffless BP devices can assess beat-to-beat BPV. Although cuffless BP monitoring devices have measurement accuracy issues that need to be resolved, this is an area of research where the evidence is accumulating rapidly, with many publications on beat-to-beat BPV over several decades. Ambulatory BP monitoring (ABPM) can assess 24-hour BPV and nocturnal dipping patterns. Day-to-day BPV and visit-to-visit BPV are assessed by self-measured BP monitoring at home and office BP measurement, respectively. 24 h, day-to-day, and visit-to-visit BPV have been reported to be associated with cardiovascular prognosis. Although there have been several studies comparing whether ABPM and self-measured BP monitoring at home is the superior measurement method of BPV, no strong evidence has been accumulated that indicates whether ABPM or self-measured home BP is superior. ABPM and self-measured BP monitoring have their own advantages and complement each other in the assessment of BPV.</p>","PeriodicalId":13029,"journal":{"name":"Hypertension Research","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of blood pressure variability: characteristics and comparison of blood pressure measurement methods.\",\"authors\":\"Keisuke Narita, Daichi Shimbo, Kazuomi Kario\",\"doi\":\"10.1038/s41440-024-01844-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Previous studies have reported that blood pressure variability (BPV) is associated with the risk of cardiovascular events independent of blood pressure (BP) levels. While there is little evidence from intervention trials examining whether suppressing BPV is useful in preventing cardiovascular disease, it is suggested that detection of abnormally elevated BPV may be useful in reducing cardiovascular events adding by complementing management of appropriate BP levels. Cuffless BP devices can assess beat-to-beat BPV. Although cuffless BP monitoring devices have measurement accuracy issues that need to be resolved, this is an area of research where the evidence is accumulating rapidly, with many publications on beat-to-beat BPV over several decades. Ambulatory BP monitoring (ABPM) can assess 24-hour BPV and nocturnal dipping patterns. Day-to-day BPV and visit-to-visit BPV are assessed by self-measured BP monitoring at home and office BP measurement, respectively. 24 h, day-to-day, and visit-to-visit BPV have been reported to be associated with cardiovascular prognosis. Although there have been several studies comparing whether ABPM and self-measured BP monitoring at home is the superior measurement method of BPV, no strong evidence has been accumulated that indicates whether ABPM or self-measured home BP is superior. ABPM and self-measured BP monitoring have their own advantages and complement each other in the assessment of BPV.</p>\",\"PeriodicalId\":13029,\"journal\":{\"name\":\"Hypertension Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hypertension Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1038/s41440-024-01844-y\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hypertension Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1038/s41440-024-01844-y","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

以往的研究表明,血压变异性(BPV)与心血管事件的风险有关,而与血压(BP)水平无关。虽然干预试验中几乎没有证据表明抑制血压变异性是否有助于预防心血管疾病,但有研究表明,检测异常升高的血压变异性可能有助于减少心血管事件的发生,同时也是对适当血压水平管理的补充。无袖带血压设备可评估每搏血压变异值。虽然无袖带血压监测设备存在测量准确性问题需要解决,但这是一个证据积累迅速的研究领域,几十年来已有许多关于逐搏血压变异的论文发表。非卧床血压监测(ABPM)可评估 24 小时血压变异值和夜间血压下降模式。逐日血压变异值和逐次血压变异值分别通过在家自测血压和办公室血压测量来评估。据报道,24 小时血压值、逐日血压值和逐次血压值与心血管预后有关。虽然有多项研究比较了 ABPM 和在家自测血压监测是否是更优越的血压变异测量方法,但目前还没有积累到有力的证据表明 ABPM 或在家自测血压更优越。ABPM 和自测血压监测在评估血压变异值方面各有优势,互为补充。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Assessment of blood pressure variability: characteristics and comparison of blood pressure measurement methods.

Assessment of blood pressure variability: characteristics and comparison of blood pressure measurement methods.

Previous studies have reported that blood pressure variability (BPV) is associated with the risk of cardiovascular events independent of blood pressure (BP) levels. While there is little evidence from intervention trials examining whether suppressing BPV is useful in preventing cardiovascular disease, it is suggested that detection of abnormally elevated BPV may be useful in reducing cardiovascular events adding by complementing management of appropriate BP levels. Cuffless BP devices can assess beat-to-beat BPV. Although cuffless BP monitoring devices have measurement accuracy issues that need to be resolved, this is an area of research where the evidence is accumulating rapidly, with many publications on beat-to-beat BPV over several decades. Ambulatory BP monitoring (ABPM) can assess 24-hour BPV and nocturnal dipping patterns. Day-to-day BPV and visit-to-visit BPV are assessed by self-measured BP monitoring at home and office BP measurement, respectively. 24 h, day-to-day, and visit-to-visit BPV have been reported to be associated with cardiovascular prognosis. Although there have been several studies comparing whether ABPM and self-measured BP monitoring at home is the superior measurement method of BPV, no strong evidence has been accumulated that indicates whether ABPM or self-measured home BP is superior. ABPM and self-measured BP monitoring have their own advantages and complement each other in the assessment of BPV.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Hypertension Research
Hypertension Research 医学-外周血管病
CiteScore
7.40
自引率
16.70%
发文量
249
审稿时长
3-8 weeks
期刊介绍: Hypertension Research is the official publication of the Japanese Society of Hypertension. The journal publishes papers reporting original clinical and experimental research that contribute to the advancement of knowledge in the field of hypertension and related cardiovascular diseases. The journal publishes Review Articles, Articles, Correspondence and Comments.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信