背部肌肉生物力学特性超声弹性成像:当前方法的系统回顾和荟萃分析。

IF 4.1 2区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Mercedes David, Karine Devantéry, Bénédicte Nauche, Miguel Chagnon, Mark Keezer, Nathaly Gaudreault, Nathalie J Bureau, Guy Cloutier
{"title":"背部肌肉生物力学特性超声弹性成像:当前方法的系统回顾和荟萃分析。","authors":"Mercedes David, Karine Devantéry, Bénédicte Nauche, Miguel Chagnon, Mark Keezer, Nathaly Gaudreault, Nathalie J Bureau, Guy Cloutier","doi":"10.1186/s13244-024-01785-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To report the current elastography methods used to quantify back muscles' biomechanical characteristics in patients with musculoskeletal disorders (MSKd) and inform on their reliability, validity, and responsiveness.</p><p><strong>Methods: </strong>MEDLINE, Embase, CINAHL, Cochrane library and grey literature were consulted. Predefined criteria allowed for study selection and data extraction. The quality of evidence was rated using the COSMIN tool. Data were meta-analyzed in terms of pooled intraclass correlation coefficient (pICC) for reliability and pooled standardized mean difference (pSMD) for validity and responsiveness. Heterogeneity was assessed.</p><p><strong>Results: </strong>Seventy-nine studies were included in the meta-analysis (total number of participants N = 3178). Three elastography methods were identified: strain imaging (SI; number of cohorts M = 26), shear wave imaging (SWI; M = 50), and vibration sonoelastography (VSE; M = 3). Strain imaging and SWI studies reported good reliability measurement properties (pICC > 0.70) and a medium pSMD (0.58 for SI and 0.60 for SWI; p ≤ 0.020) in discriminating MSKd from controls' condition (validity). Strain imaging studies reported a medium pSMD (0.64; p = 0.005) in detecting within-group changes over time, whereas SWI pSMD was very high (1.24; p = 0.005). Only SWI reported significant but small pSMD (0.30; p = 0.003) in detecting between-group changes over time. The small number of VSE studies could not be meta-analyzed. Heterogeneity was high (I-squared > 90%; p < 0.001).</p><p><strong>Conclusions: </strong>Elastography presents good reliability results and a medium pSMD in discriminating MSKd from control conditions. Responsiveness data suggest detectable changes within groups over time using SI and SWI, calling for long-term longitudinal studies. Assessing changes between groups over time using elastography still needs to be proven. Highly significant heterogeneity limits meta-analytic results.</p><p><strong>Critical relevance statement: </strong>While still in its early-stage exploration phase, musculoskeletal ultrasound elastography may reliably quantify back muscles' biomechanics in asymptomatic individuals, moderately discriminate back musculoskeletal disorders and detect biomechanical changes over time in these conditions, calling for long-term longitudinal studies.</p><p><strong>Key points: </strong>Ultrasound elastography is reviewed for back pain and related musculoskeletal disorder assessments. Growing literature supports good reproducibility, some validity and responsiveness. Back muscle elastography considers assumptions calling for standardized protocols.</p>","PeriodicalId":13639,"journal":{"name":"Insights into Imaging","volume":"15 1","pages":"206"},"PeriodicalIF":4.1000,"publicationDate":"2024-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11324641/pdf/","citationCount":"0","resultStr":"{\"title\":\"Ultrasound elastography of back muscle biomechanical properties: a systematic review and meta-analysis of current methods.\",\"authors\":\"Mercedes David, Karine Devantéry, Bénédicte Nauche, Miguel Chagnon, Mark Keezer, Nathaly Gaudreault, Nathalie J Bureau, Guy Cloutier\",\"doi\":\"10.1186/s13244-024-01785-7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To report the current elastography methods used to quantify back muscles' biomechanical characteristics in patients with musculoskeletal disorders (MSKd) and inform on their reliability, validity, and responsiveness.</p><p><strong>Methods: </strong>MEDLINE, Embase, CINAHL, Cochrane library and grey literature were consulted. Predefined criteria allowed for study selection and data extraction. The quality of evidence was rated using the COSMIN tool. Data were meta-analyzed in terms of pooled intraclass correlation coefficient (pICC) for reliability and pooled standardized mean difference (pSMD) for validity and responsiveness. Heterogeneity was assessed.</p><p><strong>Results: </strong>Seventy-nine studies were included in the meta-analysis (total number of participants N = 3178). Three elastography methods were identified: strain imaging (SI; number of cohorts M = 26), shear wave imaging (SWI; M = 50), and vibration sonoelastography (VSE; M = 3). Strain imaging and SWI studies reported good reliability measurement properties (pICC > 0.70) and a medium pSMD (0.58 for SI and 0.60 for SWI; p ≤ 0.020) in discriminating MSKd from controls' condition (validity). Strain imaging studies reported a medium pSMD (0.64; p = 0.005) in detecting within-group changes over time, whereas SWI pSMD was very high (1.24; p = 0.005). Only SWI reported significant but small pSMD (0.30; p = 0.003) in detecting between-group changes over time. The small number of VSE studies could not be meta-analyzed. Heterogeneity was high (I-squared > 90%; p < 0.001).</p><p><strong>Conclusions: </strong>Elastography presents good reliability results and a medium pSMD in discriminating MSKd from control conditions. Responsiveness data suggest detectable changes within groups over time using SI and SWI, calling for long-term longitudinal studies. Assessing changes between groups over time using elastography still needs to be proven. Highly significant heterogeneity limits meta-analytic results.</p><p><strong>Critical relevance statement: </strong>While still in its early-stage exploration phase, musculoskeletal ultrasound elastography may reliably quantify back muscles' biomechanics in asymptomatic individuals, moderately discriminate back musculoskeletal disorders and detect biomechanical changes over time in these conditions, calling for long-term longitudinal studies.</p><p><strong>Key points: </strong>Ultrasound elastography is reviewed for back pain and related musculoskeletal disorder assessments. Growing literature supports good reproducibility, some validity and responsiveness. Back muscle elastography considers assumptions calling for standardized protocols.</p>\",\"PeriodicalId\":13639,\"journal\":{\"name\":\"Insights into Imaging\",\"volume\":\"15 1\",\"pages\":\"206\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2024-08-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11324641/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Insights into Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s13244-024-01785-7\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Insights into Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13244-024-01785-7","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的报告目前用于量化肌肉骨骼疾病(MSKd)患者背部肌肉生物力学特征的弹性成像方法,并就其可靠性、有效性和响应性提供信息:方法:查阅了 MEDLINE、Embase、CINAHL、Cochrane 图书馆和灰色文献。通过预先确定的标准进行研究选择和数据提取。使用 COSMIN 工具对证据质量进行评级。根据集合类内相关系数(pICC)对数据进行了可靠性元分析,根据集合标准化平均差(pSMD)对数据进行了有效性和响应性元分析。对异质性进行了评估:荟萃分析共纳入 79 项研究(总参与人数 N = 3178)。确定了三种弹性成像方法:应变成像(SI;队列数 M = 26)、剪切波成像(SWI;M = 50)和振动声弹性成像(VSE;M = 3)。应变成像和剪切波成像研究显示,在区分 MSKd 和对照组的情况(有效性)方面,应变成像和剪切波成像具有良好的可靠性测量特性(pICC > 0.70)和中等的 pSMD(SI 为 0.58,SWI 为 0.60;p ≤ 0.020)。应变成像研究在检测组内随时间变化方面的 pSMD 为中等(0.64;p = 0.005),而 SWI 的 pSMD 非常高(1.24;p = 0.005)。只有 SWI 在检测组间随时间的变化方面报告了显著但较小的 pSMD(0.30;p = 0.003)。VSE 研究数量较少,无法进行荟萃分析。异质性很高(I-squared > 90%; p 结论:弹性成像技术在区分 MSKd 和对照组方面具有良好的可靠性和中等的 pSMD。反应性数据表明,使用 SI 和 SWI 可检测到组内随时间发生的变化,因此需要进行长期纵向研究。使用弹性成像技术评估组间随时间的变化仍有待证实。高度异质性限制了荟萃分析结果:肌肉骨骼超声弹性成像技术虽然仍处于早期探索阶段,但可以可靠地量化无症状个体背部肌肉的生物力学,适度地鉴别背部肌肉骨骼疾病,并检测这些疾病随时间推移而发生的生物力学变化,因此需要进行长期纵向研究:要点:超声弹性成像技术可用于背痛及相关肌肉骨骼疾病的评估。越来越多的文献支持良好的可重复性、一定的有效性和响应性。背部肌肉弹性成像需要考虑一些假设,这就要求制定标准化方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Ultrasound elastography of back muscle biomechanical properties: a systematic review and meta-analysis of current methods.

Objectives: To report the current elastography methods used to quantify back muscles' biomechanical characteristics in patients with musculoskeletal disorders (MSKd) and inform on their reliability, validity, and responsiveness.

Methods: MEDLINE, Embase, CINAHL, Cochrane library and grey literature were consulted. Predefined criteria allowed for study selection and data extraction. The quality of evidence was rated using the COSMIN tool. Data were meta-analyzed in terms of pooled intraclass correlation coefficient (pICC) for reliability and pooled standardized mean difference (pSMD) for validity and responsiveness. Heterogeneity was assessed.

Results: Seventy-nine studies were included in the meta-analysis (total number of participants N = 3178). Three elastography methods were identified: strain imaging (SI; number of cohorts M = 26), shear wave imaging (SWI; M = 50), and vibration sonoelastography (VSE; M = 3). Strain imaging and SWI studies reported good reliability measurement properties (pICC > 0.70) and a medium pSMD (0.58 for SI and 0.60 for SWI; p ≤ 0.020) in discriminating MSKd from controls' condition (validity). Strain imaging studies reported a medium pSMD (0.64; p = 0.005) in detecting within-group changes over time, whereas SWI pSMD was very high (1.24; p = 0.005). Only SWI reported significant but small pSMD (0.30; p = 0.003) in detecting between-group changes over time. The small number of VSE studies could not be meta-analyzed. Heterogeneity was high (I-squared > 90%; p < 0.001).

Conclusions: Elastography presents good reliability results and a medium pSMD in discriminating MSKd from control conditions. Responsiveness data suggest detectable changes within groups over time using SI and SWI, calling for long-term longitudinal studies. Assessing changes between groups over time using elastography still needs to be proven. Highly significant heterogeneity limits meta-analytic results.

Critical relevance statement: While still in its early-stage exploration phase, musculoskeletal ultrasound elastography may reliably quantify back muscles' biomechanics in asymptomatic individuals, moderately discriminate back musculoskeletal disorders and detect biomechanical changes over time in these conditions, calling for long-term longitudinal studies.

Key points: Ultrasound elastography is reviewed for back pain and related musculoskeletal disorder assessments. Growing literature supports good reproducibility, some validity and responsiveness. Back muscle elastography considers assumptions calling for standardized protocols.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Insights into Imaging
Insights into Imaging Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
7.30
自引率
4.30%
发文量
182
审稿时长
13 weeks
期刊介绍: Insights into Imaging (I³) is a peer-reviewed open access journal published under the brand SpringerOpen. All content published in the journal is freely available online to anyone, anywhere! I³ continuously updates scientific knowledge and progress in best-practice standards in radiology through the publication of original articles and state-of-the-art reviews and opinions, along with recommendations and statements from the leading radiological societies in Europe. Founded by the European Society of Radiology (ESR), I³ creates a platform for educational material, guidelines and recommendations, and a forum for topics of controversy. A balanced combination of review articles, original papers, short communications from European radiological congresses and information on society matters makes I³ an indispensable source for current information in this field. I³ is owned by the ESR, however authors retain copyright to their article according to the Creative Commons Attribution License (see Copyright and License Agreement). All articles can be read, redistributed and reused for free, as long as the author of the original work is cited properly. The open access fees (article-processing charges) for this journal are kindly sponsored by ESR for all Members. The journal went open access in 2012, which means that all articles published since then are freely available online.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信