Alfonso Queipo-de-Llano , Jorge Mariscal Lara , Antonio Leiva Gea , Borja Delgado-Rufino
{"title":"在 Rorabeck III 型假体周围膝关节骨折中使用钢板固定和骨水泥增量法固定股骨组件。一种新的手术技术和四例病例报告","authors":"Alfonso Queipo-de-Llano , Jorge Mariscal Lara , Antonio Leiva Gea , Borja Delgado-Rufino","doi":"10.1016/j.tcr.2024.101084","DOIUrl":null,"url":null,"abstract":"<div><p>Although dual implant constructs have recently been explored with promising results in very distal periprosthetic femur fractures (PPKF), the gold standard treatment of Rorabeck and Taylor type III PPKF remains a distal femur replacement or a highly constrained rotating hinge implant. However, this surgery is very aggressive and expensive for functionally low-demanding elderly patients. A new surgical technique using locking plates with polymethyl methacrylate cement augmentation is described to retain the femoral component avoiding its replacement. Four patients were treated and followed up for more than one year postoperative without any complications, their femoral component was retained without any loosening and the mobility in the Barthel Index remained unchanged.</p></div>","PeriodicalId":23291,"journal":{"name":"Trauma Case Reports","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2352644024001079/pdfft?md5=6b9a33dd33598b71d7a76491a90a22c8&pid=1-s2.0-S2352644024001079-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Femoral component retention in Rorabeck type III periprosthetic knee fracture with plating fixation and bone cement augmentation. A new surgical technique and four cases reported\",\"authors\":\"Alfonso Queipo-de-Llano , Jorge Mariscal Lara , Antonio Leiva Gea , Borja Delgado-Rufino\",\"doi\":\"10.1016/j.tcr.2024.101084\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Although dual implant constructs have recently been explored with promising results in very distal periprosthetic femur fractures (PPKF), the gold standard treatment of Rorabeck and Taylor type III PPKF remains a distal femur replacement or a highly constrained rotating hinge implant. However, this surgery is very aggressive and expensive for functionally low-demanding elderly patients. A new surgical technique using locking plates with polymethyl methacrylate cement augmentation is described to retain the femoral component avoiding its replacement. Four patients were treated and followed up for more than one year postoperative without any complications, their femoral component was retained without any loosening and the mobility in the Barthel Index remained unchanged.</p></div>\",\"PeriodicalId\":23291,\"journal\":{\"name\":\"Trauma Case Reports\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2352644024001079/pdfft?md5=6b9a33dd33598b71d7a76491a90a22c8&pid=1-s2.0-S2352644024001079-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Trauma Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352644024001079\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trauma Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352644024001079","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
摘要
尽管最近对双植入物结构进行了探索,并在极远端股骨假体周围骨折(PPKF)中取得了可喜的成果,但治疗罗拉贝克和泰勒 III 型 PPKF 的金标准仍然是股骨远端置换或高约束旋转铰链植入物。然而,对于功能要求不高的老年患者来说,这种手术非常激进且昂贵。本文介绍了一种使用聚甲基丙烯酸甲酯骨水泥增强锁定板的新手术技术,以保留股骨组件,避免其被替换。四名患者接受了治疗,术后随访一年多,未出现任何并发症,股骨组件得以保留,未出现任何松动,巴特尔指数(Barthel Index)中的活动度保持不变。
Femoral component retention in Rorabeck type III periprosthetic knee fracture with plating fixation and bone cement augmentation. A new surgical technique and four cases reported
Although dual implant constructs have recently been explored with promising results in very distal periprosthetic femur fractures (PPKF), the gold standard treatment of Rorabeck and Taylor type III PPKF remains a distal femur replacement or a highly constrained rotating hinge implant. However, this surgery is very aggressive and expensive for functionally low-demanding elderly patients. A new surgical technique using locking plates with polymethyl methacrylate cement augmentation is described to retain the femoral component avoiding its replacement. Four patients were treated and followed up for more than one year postoperative without any complications, their femoral component was retained without any loosening and the mobility in the Barthel Index remained unchanged.
期刊介绍:
Trauma Case Reports is the only open access, online journal dedicated to the publication of case reports in all aspects of trauma care and accident surgery. Case reports on all aspects of trauma management, surgical procedures for all tissues, resuscitation, anaesthesia and trauma and tissue healing will be considered for publication by the international editorial team and will be subject to peer review. Bringing together these cases from an international authorship will shed light on surgical problems and help in their effective resolution.