{"title":"优化中血管闭塞时的血栓切除术:关注血管直径。","authors":"Yujiro Tanaka, Daisuke Watanabe, Yusuke Kanoko, Aya Inoue, Daichi Kato, Shota Igasaki, Akira Kikuta, Motoyori Ogasawara, Kodai Kanemaru, Hibiku Maruoka","doi":"10.1177/15910199241272638","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Mechanical thrombectomy for medium vessel occlusion (MeVO) is a challenging field with limited results. In this study, we aimed at evaluating the efficacy and safety of a procedural strategy beginning with occluded vessel diameter measurement and matched aspiration catheter selection.</p><p><strong>Materials and methods: </strong>We retrospectively analyzed all sequentially treated patients by mechanical thrombectomy at two comprehensive stroke centers between May 2020 and April 2023, focusing on the occluded vessel diameter. We included patients who underwent thrombectomy for MeVO based on the matching strategy (a procedural approach involving vessel diameter assessment, matching aspiration catheter selection, and firm clot engagement with or without a stent retriever). We evaluated efficacy and safety using the modified Thrombolysis in the Cerebral Infarction Scale (mTICI) and intracranial hemorrhage (ICH) and procedure-related complications.</p><p><strong>Results: </strong>Seventy patients fulfilled the final inclusion criteria. The median occluded vessel diameter was 1.71 mm. We achieved mTICI 2b/2c/3 in 82.9% and mTICI 2c/3 in 51.4% of the cases and did not observe any symptomatic ICH. We detected asymptomatic subarachnoid hemorrhage (SAH) in 24.3% of the cases, that is, 5.6%, 20.0%, and 45.5% in the vessel diameter groups ≥2.0, 1.5-2.0, and ≤1.5 mm, respectively. The SAH incidence was significantly higher in narrower vessel groups. The occluded vessel diameter and the contact method with clots predicted clinical outcomes.</p><p><strong>Conclusions: </strong>Matching strategy-based thrombectomy yields acceptable efficiency and safety results. In narrower vessels, it is optimal to engage matched aspiration catheters and clots without the assistance of conventional stent retrievers.</p>","PeriodicalId":14380,"journal":{"name":"Interventional Neuroradiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569743/pdf/","citationCount":"0","resultStr":"{\"title\":\"Optimizing thrombectomy in medium vessel occlusion: Focus on vessel diameter.\",\"authors\":\"Yujiro Tanaka, Daisuke Watanabe, Yusuke Kanoko, Aya Inoue, Daichi Kato, Shota Igasaki, Akira Kikuta, Motoyori Ogasawara, Kodai Kanemaru, Hibiku Maruoka\",\"doi\":\"10.1177/15910199241272638\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Mechanical thrombectomy for medium vessel occlusion (MeVO) is a challenging field with limited results. In this study, we aimed at evaluating the efficacy and safety of a procedural strategy beginning with occluded vessel diameter measurement and matched aspiration catheter selection.</p><p><strong>Materials and methods: </strong>We retrospectively analyzed all sequentially treated patients by mechanical thrombectomy at two comprehensive stroke centers between May 2020 and April 2023, focusing on the occluded vessel diameter. We included patients who underwent thrombectomy for MeVO based on the matching strategy (a procedural approach involving vessel diameter assessment, matching aspiration catheter selection, and firm clot engagement with or without a stent retriever). We evaluated efficacy and safety using the modified Thrombolysis in the Cerebral Infarction Scale (mTICI) and intracranial hemorrhage (ICH) and procedure-related complications.</p><p><strong>Results: </strong>Seventy patients fulfilled the final inclusion criteria. The median occluded vessel diameter was 1.71 mm. We achieved mTICI 2b/2c/3 in 82.9% and mTICI 2c/3 in 51.4% of the cases and did not observe any symptomatic ICH. We detected asymptomatic subarachnoid hemorrhage (SAH) in 24.3% of the cases, that is, 5.6%, 20.0%, and 45.5% in the vessel diameter groups ≥2.0, 1.5-2.0, and ≤1.5 mm, respectively. The SAH incidence was significantly higher in narrower vessel groups. The occluded vessel diameter and the contact method with clots predicted clinical outcomes.</p><p><strong>Conclusions: </strong>Matching strategy-based thrombectomy yields acceptable efficiency and safety results. In narrower vessels, it is optimal to engage matched aspiration catheters and clots without the assistance of conventional stent retrievers.</p>\",\"PeriodicalId\":14380,\"journal\":{\"name\":\"Interventional Neuroradiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-08-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569743/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Neuroradiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15910199241272638\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199241272638","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:中血管闭塞(MeVO)的机械血栓切除术是一个具有挑战性的领域,且效果有限。在这项研究中,我们旨在评估从测量闭塞血管直径和选择匹配的抽吸导管开始的程序策略的有效性和安全性:我们回顾性分析了 2020 年 5 月至 2023 年 4 月期间在两家综合卒中中心接受机械血栓切除术的所有序贯治疗患者,重点分析了闭塞血管的直径。我们纳入了根据匹配策略(一种程序方法,包括血管直径评估、匹配抽吸导管选择、使用或不使用支架回取器进行血栓固定)对 MeVO 进行血栓切除术的患者。我们使用改良的脑梗塞溶栓量表(mTICI)评估了疗效和安全性,以及颅内出血(ICH)和手术相关并发症:70名患者符合最终纳入标准。中位闭塞血管直径为 1.71 毫米。82.9%的病例达到了 mTICI 2b/2c/3 ,51.4%的病例达到了 mTICI 2c/3,未发现任何症状性 ICH。我们在 24.3% 的病例中发现了无症状蛛网膜下腔出血(SAH),即血管直径≥2.0、1.5-2.0 和≤1.5 mm 组分别为 5.6%、20.0% 和 45.5%。血管较窄组的 SAH 发生率明显较高。闭塞血管直径和血栓接触方式可预测临床结果:结论:基于匹配策略的血栓切除术可获得可接受的效率和安全性。结论:基于匹配策略的血栓切除术可获得可接受的效率和安全性结果。在较窄的血管中,最好在不使用传统支架取栓器的情况下使用匹配的抽吸导管和血栓接触。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimizing thrombectomy in medium vessel occlusion: Focus on vessel diameter.

Objectives: Mechanical thrombectomy for medium vessel occlusion (MeVO) is a challenging field with limited results. In this study, we aimed at evaluating the efficacy and safety of a procedural strategy beginning with occluded vessel diameter measurement and matched aspiration catheter selection.

Materials and methods: We retrospectively analyzed all sequentially treated patients by mechanical thrombectomy at two comprehensive stroke centers between May 2020 and April 2023, focusing on the occluded vessel diameter. We included patients who underwent thrombectomy for MeVO based on the matching strategy (a procedural approach involving vessel diameter assessment, matching aspiration catheter selection, and firm clot engagement with or without a stent retriever). We evaluated efficacy and safety using the modified Thrombolysis in the Cerebral Infarction Scale (mTICI) and intracranial hemorrhage (ICH) and procedure-related complications.

Results: Seventy patients fulfilled the final inclusion criteria. The median occluded vessel diameter was 1.71 mm. We achieved mTICI 2b/2c/3 in 82.9% and mTICI 2c/3 in 51.4% of the cases and did not observe any symptomatic ICH. We detected asymptomatic subarachnoid hemorrhage (SAH) in 24.3% of the cases, that is, 5.6%, 20.0%, and 45.5% in the vessel diameter groups ≥2.0, 1.5-2.0, and ≤1.5 mm, respectively. The SAH incidence was significantly higher in narrower vessel groups. The occluded vessel diameter and the contact method with clots predicted clinical outcomes.

Conclusions: Matching strategy-based thrombectomy yields acceptable efficiency and safety results. In narrower vessels, it is optimal to engage matched aspiration catheters and clots without the assistance of conventional stent retrievers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.80
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信