{"title":"在高分辨率 3-T 颈动脉磁共振成像上使用 T1 加权 DANTE-SPACE 序列进行颈动脉壁分割的再现性。","authors":"So Yeon Won, Kijeong Lee, Ilah Shin, Hyun Seok Choi, Jai Ho Choi, Bum-Soo Kim, Yong Sam Shin","doi":"10.1177/02841851241268467","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>T1-weighted (T1W) magnetic resonance imaging (MRI) using the delay alternating with nutation for excitation-sampling perfection with application-optimized contrasts using different flip angle evolution (DANTE-SPACE) is the preferred imaging technique for evaluation of the vessel wall.</p><p><strong>Purpose: </strong>To evaluate the intra- and inter-rater reproducibility of carotid wall segmentation on T1W DANTE-SPACE in patients with symptomatic (acute stroke or transient ischemic attack) internal carotid artery (ICA) stenosis.</p><p><strong>Material and methods: </strong>This prospective study included 25 patients with acute (≤3 months) stroke or transient ischemic attack and 50%-99% stenosis of the ICA. All patients underwent 3.0-T high-resolution carotid MRI. Two radiologists independently performed the manual segmentation of the vessel wall and inner lumen of the bilateral carotid artery on DANTE-SPACE. The intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and Hausdorff distance (HD) were calculated.</p><p><strong>Results: </strong>The ICCs for intra-rater reproducibility of carotid wall volume, inner lumen volume, and normalized wall index were 0.965, 0.990, and 0.962, respectively. The ICCs for inter-rater reproducibility of carotid wall volume, inner lumen, and normalized wall index were 0.856, 0.981, and 0.904. DSC and HD for intra- and inter-rater reproducibility of carotid wall segmentation were as follows: 0.873 and 0.809 (DSC); and 0.079 and 0.118 (HD), respectively. For evaluation of reproducibility only in the carotid artery with symptomatic stenosis, the ICCs for intra- and inter-rater reproducibility indicated all perfect agreement.</p><p><strong>Conclusion: </strong>T1W DANTE-SPACE is a reproducible sequence for evaluation of the carotid wall using carotid MRI in patients with symptomatic ICA stenosis.</p>","PeriodicalId":7143,"journal":{"name":"Acta radiologica","volume":" ","pages":"1196-1204"},"PeriodicalIF":1.1000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reproducibility for carotid wall segmentation using T1-weighted DANTE-SPACE sequence on high-resolution 3-T carotid MRI.\",\"authors\":\"So Yeon Won, Kijeong Lee, Ilah Shin, Hyun Seok Choi, Jai Ho Choi, Bum-Soo Kim, Yong Sam Shin\",\"doi\":\"10.1177/02841851241268467\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>T1-weighted (T1W) magnetic resonance imaging (MRI) using the delay alternating with nutation for excitation-sampling perfection with application-optimized contrasts using different flip angle evolution (DANTE-SPACE) is the preferred imaging technique for evaluation of the vessel wall.</p><p><strong>Purpose: </strong>To evaluate the intra- and inter-rater reproducibility of carotid wall segmentation on T1W DANTE-SPACE in patients with symptomatic (acute stroke or transient ischemic attack) internal carotid artery (ICA) stenosis.</p><p><strong>Material and methods: </strong>This prospective study included 25 patients with acute (≤3 months) stroke or transient ischemic attack and 50%-99% stenosis of the ICA. All patients underwent 3.0-T high-resolution carotid MRI. Two radiologists independently performed the manual segmentation of the vessel wall and inner lumen of the bilateral carotid artery on DANTE-SPACE. The intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and Hausdorff distance (HD) were calculated.</p><p><strong>Results: </strong>The ICCs for intra-rater reproducibility of carotid wall volume, inner lumen volume, and normalized wall index were 0.965, 0.990, and 0.962, respectively. The ICCs for inter-rater reproducibility of carotid wall volume, inner lumen, and normalized wall index were 0.856, 0.981, and 0.904. DSC and HD for intra- and inter-rater reproducibility of carotid wall segmentation were as follows: 0.873 and 0.809 (DSC); and 0.079 and 0.118 (HD), respectively. For evaluation of reproducibility only in the carotid artery with symptomatic stenosis, the ICCs for intra- and inter-rater reproducibility indicated all perfect agreement.</p><p><strong>Conclusion: </strong>T1W DANTE-SPACE is a reproducible sequence for evaluation of the carotid wall using carotid MRI in patients with symptomatic ICA stenosis.</p>\",\"PeriodicalId\":7143,\"journal\":{\"name\":\"Acta radiologica\",\"volume\":\" \",\"pages\":\"1196-1204\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta radiologica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/02841851241268467\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/02841851241268467","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/8 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Reproducibility for carotid wall segmentation using T1-weighted DANTE-SPACE sequence on high-resolution 3-T carotid MRI.
Background: T1-weighted (T1W) magnetic resonance imaging (MRI) using the delay alternating with nutation for excitation-sampling perfection with application-optimized contrasts using different flip angle evolution (DANTE-SPACE) is the preferred imaging technique for evaluation of the vessel wall.
Purpose: To evaluate the intra- and inter-rater reproducibility of carotid wall segmentation on T1W DANTE-SPACE in patients with symptomatic (acute stroke or transient ischemic attack) internal carotid artery (ICA) stenosis.
Material and methods: This prospective study included 25 patients with acute (≤3 months) stroke or transient ischemic attack and 50%-99% stenosis of the ICA. All patients underwent 3.0-T high-resolution carotid MRI. Two radiologists independently performed the manual segmentation of the vessel wall and inner lumen of the bilateral carotid artery on DANTE-SPACE. The intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and Hausdorff distance (HD) were calculated.
Results: The ICCs for intra-rater reproducibility of carotid wall volume, inner lumen volume, and normalized wall index were 0.965, 0.990, and 0.962, respectively. The ICCs for inter-rater reproducibility of carotid wall volume, inner lumen, and normalized wall index were 0.856, 0.981, and 0.904. DSC and HD for intra- and inter-rater reproducibility of carotid wall segmentation were as follows: 0.873 and 0.809 (DSC); and 0.079 and 0.118 (HD), respectively. For evaluation of reproducibility only in the carotid artery with symptomatic stenosis, the ICCs for intra- and inter-rater reproducibility indicated all perfect agreement.
Conclusion: T1W DANTE-SPACE is a reproducible sequence for evaluation of the carotid wall using carotid MRI in patients with symptomatic ICA stenosis.
期刊介绍:
Acta Radiologica publishes articles on all aspects of radiology, from clinical radiology to experimental work. It is known for articles based on experimental work and contrast media research, giving priority to scientific original papers. The distinguished international editorial board also invite review articles, short communications and technical and instrumental notes.