肩峰下球囊垫片可改善大面积不可修复肩袖撕裂患者的等速运动能力。

IF 3.3 2区 医学 Q1 ORTHOPEDICS
Gonzalo Luengo-Alonso, Almudena Fernández-Brazo Rueda, Natalia Martínez-Catalán, Cristina Delgado, María Valencia, Emilio Calvo
{"title":"肩峰下球囊垫片可改善大面积不可修复肩袖撕裂患者的等速运动能力。","authors":"Gonzalo Luengo-Alonso, Almudena Fernández-Brazo Rueda, Natalia Martínez-Catalán, Cristina Delgado, María Valencia, Emilio Calvo","doi":"10.1002/ksa.12406","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to analyse clinical, functional and shoulder kinematics results using subacromial balloon spacer in nonreparable massive rotator cuff tears. Subacromial balloon spacer was hypothesised to improve shoulder kinematics and increases clinical and functional outcomes scores in nonreparable massive rotator cuff tears.</p><p><strong>Methods: </strong>This is a prospective study in massive rotator cuff tears. From October 2021 to October 2022, a total of 127 shoulders suffering massive rotator cuff tears were initially evaluated. All patients were evaluated preoperatively, at 6 and 12 months. Patients' patient-reported outcome measures (PROM) subjective values using visual analogue scale (VAS) and the Spanish Western Ontario Rotator Cuff Index (WORC) version were analysed. We also evaluated objective outcomes: constant score, range of movement and kinematic shoulder analysis (isokinetic test to evaluate internal and external rotation forces). Statistical analysis was conducted using SPSS software; continuous variables were presented as means and standard deviations (SDs).</p><p><strong>Results: </strong>Seventeen nonrepairable massive rotator cuff tears were finally included. Three patients required reverse shoulder arthroplasty before 6 months postoperative. After 1-year follow-up, objective and subjective (PROM) outcome scores and isokinetic measurements improved in 13 patients. Preoperative VAS improved from 6.5 ± 2.1 to 2 ± 1.9 points on average at 1-year follow-up and WORC index from 1603 ± 217.3 to 699 ± 361.6. Constant score from 42.1 ± 13.1 on average and at 1-year follow-up increased to 60.8 ± 14.7. Range of movement also improved in elevation 122.2 ± 39.3 to 166.9 ± 25.8, abduction 120.3 ± 38.6 to 134.6 ± 21.1, external rotation 30.3 ± 19.7 to 86.1 ± 13.8 and internal rotation L4-T12 on average at 1-year follow-up. Isokinetic evaluation showed functional improvement 1 year after implantation. Both internal and external rotation improved compared with their healthy shoulder. External rotation improved from 30.3° ± 19.7° preoperatively to 86.1° ± 13.8° (43.7% in the isokinetic study) and internal rotation from L4 preoperatively to L1 (49.8% in isokinetic study) on average.</p><p><strong>Conclusion: </strong>Among the different alternatives for irreparable rotator cuff injuries surgical treatment, subacromial balloon spacer is an effective alternative in selected patients, both in terms of clinical-functional improvement and short-term isokinetic results.</p><p><strong>Level of evidence: </strong>Level II.</p>","PeriodicalId":17880,"journal":{"name":"Knee Surgery, Sports Traumatology, Arthroscopy","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Subacromial balloon spacer improves isokinetic performance in patients with massive irreparable rotator cuff tear.\",\"authors\":\"Gonzalo Luengo-Alonso, Almudena Fernández-Brazo Rueda, Natalia Martínez-Catalán, Cristina Delgado, María Valencia, Emilio Calvo\",\"doi\":\"10.1002/ksa.12406\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this study was to analyse clinical, functional and shoulder kinematics results using subacromial balloon spacer in nonreparable massive rotator cuff tears. Subacromial balloon spacer was hypothesised to improve shoulder kinematics and increases clinical and functional outcomes scores in nonreparable massive rotator cuff tears.</p><p><strong>Methods: </strong>This is a prospective study in massive rotator cuff tears. From October 2021 to October 2022, a total of 127 shoulders suffering massive rotator cuff tears were initially evaluated. All patients were evaluated preoperatively, at 6 and 12 months. Patients' patient-reported outcome measures (PROM) subjective values using visual analogue scale (VAS) and the Spanish Western Ontario Rotator Cuff Index (WORC) version were analysed. We also evaluated objective outcomes: constant score, range of movement and kinematic shoulder analysis (isokinetic test to evaluate internal and external rotation forces). Statistical analysis was conducted using SPSS software; continuous variables were presented as means and standard deviations (SDs).</p><p><strong>Results: </strong>Seventeen nonrepairable massive rotator cuff tears were finally included. Three patients required reverse shoulder arthroplasty before 6 months postoperative. After 1-year follow-up, objective and subjective (PROM) outcome scores and isokinetic measurements improved in 13 patients. Preoperative VAS improved from 6.5 ± 2.1 to 2 ± 1.9 points on average at 1-year follow-up and WORC index from 1603 ± 217.3 to 699 ± 361.6. Constant score from 42.1 ± 13.1 on average and at 1-year follow-up increased to 60.8 ± 14.7. Range of movement also improved in elevation 122.2 ± 39.3 to 166.9 ± 25.8, abduction 120.3 ± 38.6 to 134.6 ± 21.1, external rotation 30.3 ± 19.7 to 86.1 ± 13.8 and internal rotation L4-T12 on average at 1-year follow-up. Isokinetic evaluation showed functional improvement 1 year after implantation. Both internal and external rotation improved compared with their healthy shoulder. External rotation improved from 30.3° ± 19.7° preoperatively to 86.1° ± 13.8° (43.7% in the isokinetic study) and internal rotation from L4 preoperatively to L1 (49.8% in isokinetic study) on average.</p><p><strong>Conclusion: </strong>Among the different alternatives for irreparable rotator cuff injuries surgical treatment, subacromial balloon spacer is an effective alternative in selected patients, both in terms of clinical-functional improvement and short-term isokinetic results.</p><p><strong>Level of evidence: </strong>Level II.</p>\",\"PeriodicalId\":17880,\"journal\":{\"name\":\"Knee Surgery, Sports Traumatology, Arthroscopy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Knee Surgery, Sports Traumatology, Arthroscopy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/ksa.12406\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee Surgery, Sports Traumatology, Arthroscopy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ksa.12406","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在分析使用肩峰下球囊垫片治疗非修复性巨大肩袖撕裂的临床、功能和肩关节运动学结果。假设肩峰下球囊垫片可改善肩关节运动学,并提高不可修复的大块肩袖撕裂患者的临床和功能结果评分:这是一项针对大面积肩袖撕裂的前瞻性研究。从 2021 年 10 月到 2022 年 10 月,共对 127 例肩袖大面积撕裂患者进行了初步评估。所有患者均接受了术前、6个月和12个月的评估。我们使用视觉类比量表(VAS)和西班牙西安大略肩袖指数(WORC)版本分析了患者的主观报告结果(PROM)。我们还对客观结果进行了评估:恒定评分、活动范围和肩关节运动学分析(等动测试,用于评估内旋和外旋力)。统计分析使用 SPSS 软件进行;连续变量以平均值和标准差(SD)表示:结果:最终纳入了 17 例不可修复的大块肩袖撕裂。结果:最终纳入了 17 名无法修复的肩袖大面积撕裂患者,其中 3 名患者在术后 6 个月前需要进行反向肩关节置换术。随访一年后,13 名患者的主客观(PROM)结果评分和等速运动测量结果均有所改善。术前 VAS 平均分从 6.5 ± 2.1 分提高到 1 年随访时的 2 ± 1.9 分,WORC 指数从 1603 ± 217.3 分提高到 699 ± 361.6 分。恒定评分从平均值(42.1 ± 13.1)提高到 1 年随访时的(60.8 ± 14.7)。随访一年时,患者的活动范围也有所改善,平均从抬高(122.2 ± 39.3)到166.9 ± 25.8,外展(120.3 ± 38.6)到134.6 ± 21.1,外旋(30.3 ± 19.7)到86.1 ± 13.8,L4-T12内旋。等速运动评估显示,植入 1 年后功能得到改善。与健康肩部相比,内旋和外旋均有所改善。外旋从术前的30.3°±19.7°提高到86.1°±13.8°(等速运动研究显示为43.7%),内旋从术前的L4提高到L1(等速运动研究显示为49.8%):结论:在不可修复的肩袖损伤手术治疗的不同替代方案中,肩峰下球囊垫片对选定的患者而言是一种有效的替代方案,无论是在临床功能改善方面还是在短期等动结果方面都是如此:证据等级:二级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Subacromial balloon spacer improves isokinetic performance in patients with massive irreparable rotator cuff tear.

Purpose: The aim of this study was to analyse clinical, functional and shoulder kinematics results using subacromial balloon spacer in nonreparable massive rotator cuff tears. Subacromial balloon spacer was hypothesised to improve shoulder kinematics and increases clinical and functional outcomes scores in nonreparable massive rotator cuff tears.

Methods: This is a prospective study in massive rotator cuff tears. From October 2021 to October 2022, a total of 127 shoulders suffering massive rotator cuff tears were initially evaluated. All patients were evaluated preoperatively, at 6 and 12 months. Patients' patient-reported outcome measures (PROM) subjective values using visual analogue scale (VAS) and the Spanish Western Ontario Rotator Cuff Index (WORC) version were analysed. We also evaluated objective outcomes: constant score, range of movement and kinematic shoulder analysis (isokinetic test to evaluate internal and external rotation forces). Statistical analysis was conducted using SPSS software; continuous variables were presented as means and standard deviations (SDs).

Results: Seventeen nonrepairable massive rotator cuff tears were finally included. Three patients required reverse shoulder arthroplasty before 6 months postoperative. After 1-year follow-up, objective and subjective (PROM) outcome scores and isokinetic measurements improved in 13 patients. Preoperative VAS improved from 6.5 ± 2.1 to 2 ± 1.9 points on average at 1-year follow-up and WORC index from 1603 ± 217.3 to 699 ± 361.6. Constant score from 42.1 ± 13.1 on average and at 1-year follow-up increased to 60.8 ± 14.7. Range of movement also improved in elevation 122.2 ± 39.3 to 166.9 ± 25.8, abduction 120.3 ± 38.6 to 134.6 ± 21.1, external rotation 30.3 ± 19.7 to 86.1 ± 13.8 and internal rotation L4-T12 on average at 1-year follow-up. Isokinetic evaluation showed functional improvement 1 year after implantation. Both internal and external rotation improved compared with their healthy shoulder. External rotation improved from 30.3° ± 19.7° preoperatively to 86.1° ± 13.8° (43.7% in the isokinetic study) and internal rotation from L4 preoperatively to L1 (49.8% in isokinetic study) on average.

Conclusion: Among the different alternatives for irreparable rotator cuff injuries surgical treatment, subacromial balloon spacer is an effective alternative in selected patients, both in terms of clinical-functional improvement and short-term isokinetic results.

Level of evidence: Level II.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.10
自引率
18.40%
发文量
418
审稿时长
2 months
期刊介绍: Few other areas of orthopedic surgery and traumatology have undergone such a dramatic evolution in the last 10 years as knee surgery, arthroscopy and sports traumatology. Ranked among the top 33% of journals in both Orthopedics and Sports Sciences, the goal of this European journal is to publish papers about innovative knee surgery, sports trauma surgery and arthroscopy. Each issue features a series of peer-reviewed articles that deal with diagnosis and management and with basic research. Each issue also contains at least one review article about an important clinical problem. Case presentations or short notes about technical innovations are also accepted for publication. The articles cover all aspects of knee surgery and all types of sports trauma; in addition, epidemiology, diagnosis, treatment and prevention, and all types of arthroscopy (not only the knee but also the shoulder, elbow, wrist, hip, ankle, etc.) are addressed. Articles on new diagnostic techniques such as MRI and ultrasound and high-quality articles about the biomechanics of joints, muscles and tendons are included. Although this is largely a clinical journal, it is also open to basic research with clinical relevance. Because the journal is supported by a distinguished European Editorial Board, assisted by an international Advisory Board, you can be assured that the journal maintains the highest standards. Official Clinical Journal of the European Society of Sports Traumatology, Knee Surgery and Arthroscopy (ESSKA).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信