Beatriz Paredes, Javier Mora de Oñate, Dolores Martín Sánchez, David P Piñero
{"title":"使用两种型号的后房型法康眼内透镜对穹窿进行表征。","authors":"Beatriz Paredes, Javier Mora de Oñate, Dolores Martín Sánchez, David P Piñero","doi":"10.1097/j.jcrs.0000000000001536","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate and compare dynamic vault range (DVR) and asymmetry of the vault during a 3-month follow-up after the implantation of 2 posterior chamber phakic intraocular lenses (pIOLs).</p><p><strong>Setting: </strong>Aver Clinic, Madrid, Spain.</p><p><strong>Design: </strong>Prospective comparative study.</p><p><strong>Methods: </strong>119 eyes (65 patients) that underwent refractive surgical correction with implantation of 1 of 2 distinct pIOLs were enrolled: Eyecryl Phakic from Biotech Vision Care (Eyecryl group, 72 eyes) and Evo Visian Implantable Contact Lens from Staar Surgical (ICL group, 47 eyes). Besides evaluation of visual acuity, refraction, and ocular integrity, the pIOL vault centrally and at 2 mm nasally and temporally as well as the DVR from photopic (50 lux) to mesopic (10 lux) illumination conditions were measured.</p><p><strong>Results: </strong>No significant differences were found between the pIOL groups in visual and refractive outcomes ( P ≥ .454). No significant differences between the groups were found in central (523.72 ± 168.4 vs 494.16 ± 156.7 μm, P = .248) and temporal (499.43 ± 155.8 vs 431.28 ± 150.5 μm, P = .067) vaults. However, nasal vault was significantly lower in the ICL group (465.6 ± 149.1 vs 375.4 ± 144.0 μm, P = .045). A trend of a larger DVR was observed in the ICL group, although differences between groups did not reach statistical significance (54.00 ± 36.39 vs 86.5 ± 57.9 μm, P = .070). The pIOL diameter only correlated significantly with vault measurements in the ICL group ( r ≥ 0.650, P < .001).</p><p><strong>Conclusions: </strong>The Eyecryl pIOL showed more symmetric vaults and a trend of fewer light-induced changes in the central vault compared with the ICL pIOL. The clinical relevance of this finding should be investigated further.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":"1262-1269"},"PeriodicalIF":2.6000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11556799/pdf/","citationCount":"0","resultStr":"{\"title\":\"Characterization of vault with two models of posterior chamber phakic intraocular lenses.\",\"authors\":\"Beatriz Paredes, Javier Mora de Oñate, Dolores Martín Sánchez, David P Piñero\",\"doi\":\"10.1097/j.jcrs.0000000000001536\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate and compare dynamic vault range (DVR) and asymmetry of the vault during a 3-month follow-up after the implantation of 2 posterior chamber phakic intraocular lenses (pIOLs).</p><p><strong>Setting: </strong>Aver Clinic, Madrid, Spain.</p><p><strong>Design: </strong>Prospective comparative study.</p><p><strong>Methods: </strong>119 eyes (65 patients) that underwent refractive surgical correction with implantation of 1 of 2 distinct pIOLs were enrolled: Eyecryl Phakic from Biotech Vision Care (Eyecryl group, 72 eyes) and Evo Visian Implantable Contact Lens from Staar Surgical (ICL group, 47 eyes). Besides evaluation of visual acuity, refraction, and ocular integrity, the pIOL vault centrally and at 2 mm nasally and temporally as well as the DVR from photopic (50 lux) to mesopic (10 lux) illumination conditions were measured.</p><p><strong>Results: </strong>No significant differences were found between the pIOL groups in visual and refractive outcomes ( P ≥ .454). No significant differences between the groups were found in central (523.72 ± 168.4 vs 494.16 ± 156.7 μm, P = .248) and temporal (499.43 ± 155.8 vs 431.28 ± 150.5 μm, P = .067) vaults. However, nasal vault was significantly lower in the ICL group (465.6 ± 149.1 vs 375.4 ± 144.0 μm, P = .045). A trend of a larger DVR was observed in the ICL group, although differences between groups did not reach statistical significance (54.00 ± 36.39 vs 86.5 ± 57.9 μm, P = .070). The pIOL diameter only correlated significantly with vault measurements in the ICL group ( r ≥ 0.650, P < .001).</p><p><strong>Conclusions: </strong>The Eyecryl pIOL showed more symmetric vaults and a trend of fewer light-induced changes in the central vault compared with the ICL pIOL. The clinical relevance of this finding should be investigated further.</p>\",\"PeriodicalId\":15214,\"journal\":{\"name\":\"Journal of cataract and refractive surgery\",\"volume\":\" \",\"pages\":\"1262-1269\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11556799/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cataract and refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/j.jcrs.0000000000001536\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001536","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
目的: 评估并比较两种后房型人工晶体(pIOL)植入后 3 个月随访期间的动态穹窿范围(DVR)和穹窿不对称情况:设计:前瞻性比较研究:设计:前瞻性比较研究:方法:研究对象包括接受屈光手术矫正并植入两种不同人工晶体之一的 119 只眼睛(65 名患者):Biotech Vision Care 公司的 Eyecryl Phakic(Eyecryl 组,72 只眼睛)和 Staar Surgical 公司的 Evo Visian Implantable Contact Lens(ICL 组,47 只眼睛)。除了对视力、屈光度和眼球完整性进行评估外,还测量了pIOL穹窿的中心位置、鼻侧和颞侧2毫米的位置,以及从光照(50勒克斯)到中光照(10勒克斯)条件下的DVR:在视觉和屈光结果方面,pIOL 组间无明显差异(p≥0.454)。中心穹窿(523.72±168.4 vs. 494.16±156.7 µm,p=0.248)和颞穹窿(499.43±155.8 vs. 431.28±150.5 µm,p=0.067)组间无明显差异。然而,ICL 组的鼻穹隆明显较低(465.6±149.1 vs. 375.4±144.0 µm,p=0.045)。虽然组间差异未达到统计学意义(54.00±36.39 vs. 86.5±57.9 µm, p=0.070),但在 ICL 组中观察到 DVR 变大的趋势。只有 ICL 组的 pIOL 直径与穹窿测量值有显著相关性(r≥0.650,p 结论:与 ICL pIOL 相比,Eyecryl pIOL 显示出更对称的穹窿,并且中央穹窿由光线引起的变化有减少的趋势。这一发现的临床意义有待进一步研究。
Characterization of vault with two models of posterior chamber phakic intraocular lenses.
Purpose: To evaluate and compare dynamic vault range (DVR) and asymmetry of the vault during a 3-month follow-up after the implantation of 2 posterior chamber phakic intraocular lenses (pIOLs).
Setting: Aver Clinic, Madrid, Spain.
Design: Prospective comparative study.
Methods: 119 eyes (65 patients) that underwent refractive surgical correction with implantation of 1 of 2 distinct pIOLs were enrolled: Eyecryl Phakic from Biotech Vision Care (Eyecryl group, 72 eyes) and Evo Visian Implantable Contact Lens from Staar Surgical (ICL group, 47 eyes). Besides evaluation of visual acuity, refraction, and ocular integrity, the pIOL vault centrally and at 2 mm nasally and temporally as well as the DVR from photopic (50 lux) to mesopic (10 lux) illumination conditions were measured.
Results: No significant differences were found between the pIOL groups in visual and refractive outcomes ( P ≥ .454). No significant differences between the groups were found in central (523.72 ± 168.4 vs 494.16 ± 156.7 μm, P = .248) and temporal (499.43 ± 155.8 vs 431.28 ± 150.5 μm, P = .067) vaults. However, nasal vault was significantly lower in the ICL group (465.6 ± 149.1 vs 375.4 ± 144.0 μm, P = .045). A trend of a larger DVR was observed in the ICL group, although differences between groups did not reach statistical significance (54.00 ± 36.39 vs 86.5 ± 57.9 μm, P = .070). The pIOL diameter only correlated significantly with vault measurements in the ICL group ( r ≥ 0.650, P < .001).
Conclusions: The Eyecryl pIOL showed more symmetric vaults and a trend of fewer light-induced changes in the central vault compared with the ICL pIOL. The clinical relevance of this finding should be investigated further.
期刊介绍:
The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS).
JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.