{"title":"泰国糖尿病视网膜病变、湿性老年性黄斑变性和白内障患者的健康效用值:使用时间权衡、EQ-5D-5L 和健康效用指数的多中心调查 3.","authors":"Pear Ferreira Pongsachareonnont MD, MPH , Phantipa Sakthong PhD , Voraporn Chaikitmongkol MD , Wantanee Dangboon Tsutsumi MD , Chavakij Bhoomibunchoo MD , Cameron P. Hurst PhD , Yot Teerawattananon MD, PhD , Kittisak Kulvichit MD","doi":"10.1016/j.vhri.2024.101030","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>This study aimed to establish normative health utility data in Thai patients with diabetic retinopathy, wet age-related macular degeneration, and cataract; evaluate the sensitivity of different utility instruments to visual impairment; explore the relationship among these health utility values with the vision-specific quality of life (QoL); and assess the association of baseline characteristics and visual acuity level with health utility values and vision-specific QoL.</p></div><div><h3>Methods</h3><p>This multicenter cross-sectional survey included 309 patients from tertiary eye centers. We used health utility instruments (time trade-off [TTO], EuroQol five-dimension [EQ-5D-5L], and Health Utility Index 3 [HUI3]) and vision-specific QoL instrument (National Eye Institute Visual Function Questionnaire) for face-to-face interviews. Demographic data and Early Treatment Diabetic Retinopathy Study visual acuity were recorded during the participants ophthalmic visits. Univariable and multivariable mixed-effect models were used to evaluate factors associated with the utility scores. Health utility scores among each type of eye disease were compared.</p></div><div><h3>Results</h3><p>The overall mean utility values from the TTO, EQ-5D-5L, and HUI3 were 0.84 ± 0.25, 0.70 ± 0.19, and 0.68 ± 0.26, respectively. The health utility scores obtained from TTO and HUI3 showed a significant response to severe visual impairment or worse. Health utility scores from HUI3 (r = 0.54; <em>P</em> < .01) and EQ-5D-5L (r = 0.43; <em>P</em> < .01) displayed a moderate correlation with the National Eye Institute Visual Function Questionnaire score. There were no significant differences in health utility value among the 3 diseases upon adjusting for the visual acuity level and demographics.</p></div><div><h3>Conclusions</h3><p>Visual acuity level has a greater impact on a patient’s QoL than the type of eye disease. HUI3 and EQ-5D-5L and TTO are suitable for measuring health utility in leading causes of blindness.</p></div>","PeriodicalId":23497,"journal":{"name":"Value in health regional issues","volume":"44 ","pages":"Article 101030"},"PeriodicalIF":1.4000,"publicationDate":"2024-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Health Utility Values Among Patients With Diabetic Retinopathy, Wet Age-Related Macular Degeneration, and Cataract in Thailand: A Multicenter Survey Using Time Trade-Off, EQ-5D-5L, and Health Utility Index 3\",\"authors\":\"Pear Ferreira Pongsachareonnont MD, MPH , Phantipa Sakthong PhD , Voraporn Chaikitmongkol MD , Wantanee Dangboon Tsutsumi MD , Chavakij Bhoomibunchoo MD , Cameron P. Hurst PhD , Yot Teerawattananon MD, PhD , Kittisak Kulvichit MD\",\"doi\":\"10.1016/j.vhri.2024.101030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objectives</h3><p>This study aimed to establish normative health utility data in Thai patients with diabetic retinopathy, wet age-related macular degeneration, and cataract; evaluate the sensitivity of different utility instruments to visual impairment; explore the relationship among these health utility values with the vision-specific quality of life (QoL); and assess the association of baseline characteristics and visual acuity level with health utility values and vision-specific QoL.</p></div><div><h3>Methods</h3><p>This multicenter cross-sectional survey included 309 patients from tertiary eye centers. We used health utility instruments (time trade-off [TTO], EuroQol five-dimension [EQ-5D-5L], and Health Utility Index 3 [HUI3]) and vision-specific QoL instrument (National Eye Institute Visual Function Questionnaire) for face-to-face interviews. Demographic data and Early Treatment Diabetic Retinopathy Study visual acuity were recorded during the participants ophthalmic visits. Univariable and multivariable mixed-effect models were used to evaluate factors associated with the utility scores. Health utility scores among each type of eye disease were compared.</p></div><div><h3>Results</h3><p>The overall mean utility values from the TTO, EQ-5D-5L, and HUI3 were 0.84 ± 0.25, 0.70 ± 0.19, and 0.68 ± 0.26, respectively. The health utility scores obtained from TTO and HUI3 showed a significant response to severe visual impairment or worse. Health utility scores from HUI3 (r = 0.54; <em>P</em> < .01) and EQ-5D-5L (r = 0.43; <em>P</em> < .01) displayed a moderate correlation with the National Eye Institute Visual Function Questionnaire score. There were no significant differences in health utility value among the 3 diseases upon adjusting for the visual acuity level and demographics.</p></div><div><h3>Conclusions</h3><p>Visual acuity level has a greater impact on a patient’s QoL than the type of eye disease. HUI3 and EQ-5D-5L and TTO are suitable for measuring health utility in leading causes of blindness.</p></div>\",\"PeriodicalId\":23497,\"journal\":{\"name\":\"Value in health regional issues\",\"volume\":\"44 \",\"pages\":\"Article 101030\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Value in health regional issues\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2212109924000633\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HEALTH CARE SCIENCES & SERVICES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Value in health regional issues","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212109924000633","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
Health Utility Values Among Patients With Diabetic Retinopathy, Wet Age-Related Macular Degeneration, and Cataract in Thailand: A Multicenter Survey Using Time Trade-Off, EQ-5D-5L, and Health Utility Index 3
Objectives
This study aimed to establish normative health utility data in Thai patients with diabetic retinopathy, wet age-related macular degeneration, and cataract; evaluate the sensitivity of different utility instruments to visual impairment; explore the relationship among these health utility values with the vision-specific quality of life (QoL); and assess the association of baseline characteristics and visual acuity level with health utility values and vision-specific QoL.
Methods
This multicenter cross-sectional survey included 309 patients from tertiary eye centers. We used health utility instruments (time trade-off [TTO], EuroQol five-dimension [EQ-5D-5L], and Health Utility Index 3 [HUI3]) and vision-specific QoL instrument (National Eye Institute Visual Function Questionnaire) for face-to-face interviews. Demographic data and Early Treatment Diabetic Retinopathy Study visual acuity were recorded during the participants ophthalmic visits. Univariable and multivariable mixed-effect models were used to evaluate factors associated with the utility scores. Health utility scores among each type of eye disease were compared.
Results
The overall mean utility values from the TTO, EQ-5D-5L, and HUI3 were 0.84 ± 0.25, 0.70 ± 0.19, and 0.68 ± 0.26, respectively. The health utility scores obtained from TTO and HUI3 showed a significant response to severe visual impairment or worse. Health utility scores from HUI3 (r = 0.54; P < .01) and EQ-5D-5L (r = 0.43; P < .01) displayed a moderate correlation with the National Eye Institute Visual Function Questionnaire score. There were no significant differences in health utility value among the 3 diseases upon adjusting for the visual acuity level and demographics.
Conclusions
Visual acuity level has a greater impact on a patient’s QoL than the type of eye disease. HUI3 and EQ-5D-5L and TTO are suitable for measuring health utility in leading causes of blindness.