Iris Nogueira Bincelli Seckler, Rina Andréa Pelegrine, Carolina Pessoa Stringheta, Ricardo Tadeu Lopes, Aline Saddock de Sá Silva, Carlos Eduardo da Silveira Bueno
{"title":"椭圆形根管中 Bio-C 封闭剂和 AH-Plus 清除辅助清洁技术的比较评估:显微 CT 分析","authors":"Iris Nogueira Bincelli Seckler, Rina Andréa Pelegrine, Carolina Pessoa Stringheta, Ricardo Tadeu Lopes, Aline Saddock de Sá Silva, Carlos Eduardo da Silveira Bueno","doi":"10.22037/iej.v19i3.43580","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This study aimed to compare the effectiveness of two endodontic cleaning techniques, passive ultrasonic irrigation (PUI) and the XP-endo Finisher R (XPR) system, in removing residual filling material during endodontic retreatment procedures.</p><p><strong>Materials and methods: </strong>Forty mandibular premolars with oval canals were divided into four groups based on the sealer used (AH-Plus or Bio-C Sealer) and the cleaning technique employed (PUI or XPR). To ensure uniformity of canal volume among groups, initial micro-CT scans were conducted. The canals were instrumented, filled, and then re-instrumented before undergoing either PUI or XPR cleaning techniques. Residual filling material volumes were assessed through micro-CT scans, and statistical analysis was performed using the Kruskal-Wallis and Mann-Whitney U tests.</p><p><strong>Results: </strong>Following instrumentation, there was no significant difference in residual filling material volumes between AH-Plus and Bio-C Sealer groups (1.35 mm<sup>3</sup>and 1.02 mm<sup>3</sup>, respectively; <i>P</i>>0.05). However, after supplementary cleaning techniques, XPR-cleaned specimens exhibited significantly less residual material compared to PUI-cleaned specimens (0.01 mm<sup>3</sup> and 0.29 mm<sup>3</sup> for Bio-C Sealer, and 0.07 mm<sup>3</sup> and. 0.30 mm<sup>3</sup> for AH-Plus, <i>P</i><0.05).</p><p><strong>Conclusion: </strong>The XPR system was found to be more effective than PUI in removing residual filling material from Bio-C Sealer-filled root canals. This highlights its potential as a useful supplementary cleaning technique in endodontic retreatment procedures.</p>","PeriodicalId":14534,"journal":{"name":"Iranian Endodontic Journal","volume":"19 3","pages":"199-207"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11287049/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparative Evaluation of Supplementary Cleaning Techniques for Removal of Bio-C Sealer and AH-Plus from Oval Root Canals: A Micro-CT Analysis.\",\"authors\":\"Iris Nogueira Bincelli Seckler, Rina Andréa Pelegrine, Carolina Pessoa Stringheta, Ricardo Tadeu Lopes, Aline Saddock de Sá Silva, Carlos Eduardo da Silveira Bueno\",\"doi\":\"10.22037/iej.v19i3.43580\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>This study aimed to compare the effectiveness of two endodontic cleaning techniques, passive ultrasonic irrigation (PUI) and the XP-endo Finisher R (XPR) system, in removing residual filling material during endodontic retreatment procedures.</p><p><strong>Materials and methods: </strong>Forty mandibular premolars with oval canals were divided into four groups based on the sealer used (AH-Plus or Bio-C Sealer) and the cleaning technique employed (PUI or XPR). To ensure uniformity of canal volume among groups, initial micro-CT scans were conducted. The canals were instrumented, filled, and then re-instrumented before undergoing either PUI or XPR cleaning techniques. Residual filling material volumes were assessed through micro-CT scans, and statistical analysis was performed using the Kruskal-Wallis and Mann-Whitney U tests.</p><p><strong>Results: </strong>Following instrumentation, there was no significant difference in residual filling material volumes between AH-Plus and Bio-C Sealer groups (1.35 mm<sup>3</sup>and 1.02 mm<sup>3</sup>, respectively; <i>P</i>>0.05). However, after supplementary cleaning techniques, XPR-cleaned specimens exhibited significantly less residual material compared to PUI-cleaned specimens (0.01 mm<sup>3</sup> and 0.29 mm<sup>3</sup> for Bio-C Sealer, and 0.07 mm<sup>3</sup> and. 0.30 mm<sup>3</sup> for AH-Plus, <i>P</i><0.05).</p><p><strong>Conclusion: </strong>The XPR system was found to be more effective than PUI in removing residual filling material from Bio-C Sealer-filled root canals. This highlights its potential as a useful supplementary cleaning technique in endodontic retreatment procedures.</p>\",\"PeriodicalId\":14534,\"journal\":{\"name\":\"Iranian Endodontic Journal\",\"volume\":\"19 3\",\"pages\":\"199-207\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11287049/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Endodontic Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22037/iej.v19i3.43580\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Endodontic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22037/iej.v19i3.43580","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
Comparative Evaluation of Supplementary Cleaning Techniques for Removal of Bio-C Sealer and AH-Plus from Oval Root Canals: A Micro-CT Analysis.
Introduction: This study aimed to compare the effectiveness of two endodontic cleaning techniques, passive ultrasonic irrigation (PUI) and the XP-endo Finisher R (XPR) system, in removing residual filling material during endodontic retreatment procedures.
Materials and methods: Forty mandibular premolars with oval canals were divided into four groups based on the sealer used (AH-Plus or Bio-C Sealer) and the cleaning technique employed (PUI or XPR). To ensure uniformity of canal volume among groups, initial micro-CT scans were conducted. The canals were instrumented, filled, and then re-instrumented before undergoing either PUI or XPR cleaning techniques. Residual filling material volumes were assessed through micro-CT scans, and statistical analysis was performed using the Kruskal-Wallis and Mann-Whitney U tests.
Results: Following instrumentation, there was no significant difference in residual filling material volumes between AH-Plus and Bio-C Sealer groups (1.35 mm3and 1.02 mm3, respectively; P>0.05). However, after supplementary cleaning techniques, XPR-cleaned specimens exhibited significantly less residual material compared to PUI-cleaned specimens (0.01 mm3 and 0.29 mm3 for Bio-C Sealer, and 0.07 mm3 and. 0.30 mm3 for AH-Plus, P<0.05).
Conclusion: The XPR system was found to be more effective than PUI in removing residual filling material from Bio-C Sealer-filled root canals. This highlights its potential as a useful supplementary cleaning technique in endodontic retreatment procedures.
期刊介绍:
The Iranian Endodontic Journal (IEJ) is an international peer-reviewed biomedical publication, the aim of which is to provide a scientific medium of communication for researchers throughout the globe. IEJ aims to publish the highest quality articles, both clinical and scientific, on all aspects of Endodontics. The journal is an official Journal of the Iranian Center for Endodontic Research (ICER) and the Iranian Association of Endodontists (IAE). The Journal welcomes articles related to the scientific or applied aspects of endodontics e.g. original researches, systematic reviews, meta-analyses, review articles, clinical trials, case series/reports, hypotheses, letters to the editor, etc. From the beginning (i.e. since 2006), the IEJ was the first open access endodontic journal in the world, which gave readers free and instant access to published articles and enabling them faster discovery of the latest endodontic research.