J Christensen, L H Matzen, M Hedegaard, R Spin-Neto
{"title":"在锥形束 CT 采集前获取的 Scout 图像:结果的再现性和附加诊断信息。","authors":"J Christensen, L H Matzen, M Hedegaard, R Spin-Neto","doi":"10.1093/dmfr/twae039","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of the present study was to assess the reproducibility of findings in cone beam computed tomography (CBCT) scout images. Furthermore, the study aimed to assess whether a scout image shows pathology not seen within the CBCT volume (ie, added diagnostic information) and therefore must be assessed on the same terms as the full volume.</p><p><strong>Methods: </strong>Using a retrospective design, 233 CBCT reports and scout images were assessed. Kappa statistics and percentage of accordance were used to evaluate intra- and interobserver reproducibility as well as agreement between scout and CBCT report.</p><p><strong>Results: </strong>Intra- and interobserver reproducibility were overall low (kappa ranging from -0.008 to 1.000). Agreement between findings reported in the CBCT and scout was also low. One-hundred-fourteen impacted teeth, one apical periodontitis, and two sinus conditions seen in the scout image were not registered in the full volume report due to the extended size of the scout image.</p><p><strong>Conclusions: </strong>Reproducibility of findings in scout images compared to CBCT volumes was low, and the scout showed very little additional diagnostic information.</p><p><strong>Advances in knowledge: </strong>This study shows that although the reproducibility of viewing scout images is low, rare findings can go undetected if the scout is not assessed. Legislation regarding interpretation of scout images needs to be discussed.</p>","PeriodicalId":11261,"journal":{"name":"Dento maxillo facial radiology","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Scout images acquired prior to cone beam CT acquisitions: reproducibility of findings and added diagnostic information.\",\"authors\":\"J Christensen, L H Matzen, M Hedegaard, R Spin-Neto\",\"doi\":\"10.1093/dmfr/twae039\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The aim of the present study was to assess the reproducibility of findings in cone beam computed tomography (CBCT) scout images. Furthermore, the study aimed to assess whether a scout image shows pathology not seen within the CBCT volume (ie, added diagnostic information) and therefore must be assessed on the same terms as the full volume.</p><p><strong>Methods: </strong>Using a retrospective design, 233 CBCT reports and scout images were assessed. Kappa statistics and percentage of accordance were used to evaluate intra- and interobserver reproducibility as well as agreement between scout and CBCT report.</p><p><strong>Results: </strong>Intra- and interobserver reproducibility were overall low (kappa ranging from -0.008 to 1.000). Agreement between findings reported in the CBCT and scout was also low. One-hundred-fourteen impacted teeth, one apical periodontitis, and two sinus conditions seen in the scout image were not registered in the full volume report due to the extended size of the scout image.</p><p><strong>Conclusions: </strong>Reproducibility of findings in scout images compared to CBCT volumes was low, and the scout showed very little additional diagnostic information.</p><p><strong>Advances in knowledge: </strong>This study shows that although the reproducibility of viewing scout images is low, rare findings can go undetected if the scout is not assessed. Legislation regarding interpretation of scout images needs to be discussed.</p>\",\"PeriodicalId\":11261,\"journal\":{\"name\":\"Dento maxillo facial radiology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dento maxillo facial radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/dmfr/twae039\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dento maxillo facial radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/dmfr/twae039","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Scout images acquired prior to cone beam CT acquisitions: reproducibility of findings and added diagnostic information.
Objectives: The aim of the present study was to assess the reproducibility of findings in cone beam computed tomography (CBCT) scout images. Furthermore, the study aimed to assess whether a scout image shows pathology not seen within the CBCT volume (ie, added diagnostic information) and therefore must be assessed on the same terms as the full volume.
Methods: Using a retrospective design, 233 CBCT reports and scout images were assessed. Kappa statistics and percentage of accordance were used to evaluate intra- and interobserver reproducibility as well as agreement between scout and CBCT report.
Results: Intra- and interobserver reproducibility were overall low (kappa ranging from -0.008 to 1.000). Agreement between findings reported in the CBCT and scout was also low. One-hundred-fourteen impacted teeth, one apical periodontitis, and two sinus conditions seen in the scout image were not registered in the full volume report due to the extended size of the scout image.
Conclusions: Reproducibility of findings in scout images compared to CBCT volumes was low, and the scout showed very little additional diagnostic information.
Advances in knowledge: This study shows that although the reproducibility of viewing scout images is low, rare findings can go undetected if the scout is not assessed. Legislation regarding interpretation of scout images needs to be discussed.
期刊介绍:
Dentomaxillofacial Radiology (DMFR) is the journal of the International Association of Dentomaxillofacial Radiology (IADMFR) and covers the closely related fields of oral radiology and head and neck imaging.
Established in 1972, DMFR is a key resource keeping dentists, radiologists and clinicians and scientists with an interest in Head and Neck imaging abreast of important research and developments in oral and maxillofacial radiology.
The DMFR editorial board features a panel of international experts including Editor-in-Chief Professor Ralf Schulze. Our editorial board provide their expertise and guidance in shaping the content and direction of the journal.
Quick Facts:
- 2015 Impact Factor - 1.919
- Receipt to first decision - average of 3 weeks
- Acceptance to online publication - average of 3 weeks
- Open access option
- ISSN: 0250-832X
- eISSN: 1476-542X