Audran Poher, Gérémy Michaud, L. Archambault, Luc Beaulieu
{"title":"利用偏振成像进行切伦科夫剂量测定时信号源与照相机距离的影响","authors":"Audran Poher, Gérémy Michaud, L. Archambault, Luc Beaulieu","doi":"10.1088/1742-6596/2799/1/012003","DOIUrl":null,"url":null,"abstract":"\n As Cherenkov emissions are related to dose, they can be used as signal for dosimetric purposes using polarized imaging. However, when using this method, angular corrections must be applied because of Cherenkov anisotropy. Several Cherenkov light source-to-camera distances were tested to characterize its impact on the deviations from reference values of the calculated dose distributions. Average relative differences ranging from −1.6% to −11% between Cherenkov-based results and scintillation results were extracted. It is observed that an increase in Cherenkov light source-to-camera distance decreases the difference between the Cherenkov optical signal and the dose. This reduces the importance of angular corrections at higher distances (4 m and beyond).","PeriodicalId":506941,"journal":{"name":"Journal of Physics: Conference Series","volume":"24 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of signal source to camera distance in Cherenkov dosimetry using polarized imaging\",\"authors\":\"Audran Poher, Gérémy Michaud, L. Archambault, Luc Beaulieu\",\"doi\":\"10.1088/1742-6596/2799/1/012003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n As Cherenkov emissions are related to dose, they can be used as signal for dosimetric purposes using polarized imaging. However, when using this method, angular corrections must be applied because of Cherenkov anisotropy. Several Cherenkov light source-to-camera distances were tested to characterize its impact on the deviations from reference values of the calculated dose distributions. Average relative differences ranging from −1.6% to −11% between Cherenkov-based results and scintillation results were extracted. It is observed that an increase in Cherenkov light source-to-camera distance decreases the difference between the Cherenkov optical signal and the dose. This reduces the importance of angular corrections at higher distances (4 m and beyond).\",\"PeriodicalId\":506941,\"journal\":{\"name\":\"Journal of Physics: Conference Series\",\"volume\":\"24 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Physics: Conference Series\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/1742-6596/2799/1/012003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physics: Conference Series","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1742-6596/2799/1/012003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effects of signal source to camera distance in Cherenkov dosimetry using polarized imaging
As Cherenkov emissions are related to dose, they can be used as signal for dosimetric purposes using polarized imaging. However, when using this method, angular corrections must be applied because of Cherenkov anisotropy. Several Cherenkov light source-to-camera distances were tested to characterize its impact on the deviations from reference values of the calculated dose distributions. Average relative differences ranging from −1.6% to −11% between Cherenkov-based results and scintillation results were extracted. It is observed that an increase in Cherenkov light source-to-camera distance decreases the difference between the Cherenkov optical signal and the dose. This reduces the importance of angular corrections at higher distances (4 m and beyond).