利用偏振成像进行切伦科夫剂量测定时信号源与照相机距离的影响

Audran Poher, Gérémy Michaud, L. Archambault, Luc Beaulieu
{"title":"利用偏振成像进行切伦科夫剂量测定时信号源与照相机距离的影响","authors":"Audran Poher, Gérémy Michaud, L. Archambault, Luc Beaulieu","doi":"10.1088/1742-6596/2799/1/012003","DOIUrl":null,"url":null,"abstract":"\n As Cherenkov emissions are related to dose, they can be used as signal for dosimetric purposes using polarized imaging. However, when using this method, angular corrections must be applied because of Cherenkov anisotropy. Several Cherenkov light source-to-camera distances were tested to characterize its impact on the deviations from reference values of the calculated dose distributions. Average relative differences ranging from −1.6% to −11% between Cherenkov-based results and scintillation results were extracted. It is observed that an increase in Cherenkov light source-to-camera distance decreases the difference between the Cherenkov optical signal and the dose. This reduces the importance of angular corrections at higher distances (4 m and beyond).","PeriodicalId":506941,"journal":{"name":"Journal of Physics: Conference Series","volume":"24 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of signal source to camera distance in Cherenkov dosimetry using polarized imaging\",\"authors\":\"Audran Poher, Gérémy Michaud, L. Archambault, Luc Beaulieu\",\"doi\":\"10.1088/1742-6596/2799/1/012003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n As Cherenkov emissions are related to dose, they can be used as signal for dosimetric purposes using polarized imaging. However, when using this method, angular corrections must be applied because of Cherenkov anisotropy. Several Cherenkov light source-to-camera distances were tested to characterize its impact on the deviations from reference values of the calculated dose distributions. Average relative differences ranging from −1.6% to −11% between Cherenkov-based results and scintillation results were extracted. It is observed that an increase in Cherenkov light source-to-camera distance decreases the difference between the Cherenkov optical signal and the dose. This reduces the importance of angular corrections at higher distances (4 m and beyond).\",\"PeriodicalId\":506941,\"journal\":{\"name\":\"Journal of Physics: Conference Series\",\"volume\":\"24 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Physics: Conference Series\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/1742-6596/2799/1/012003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physics: Conference Series","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1742-6596/2799/1/012003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于切伦科夫辐射与剂量有关,因此可以利用偏振成像将其作为剂量测定的信号。不过,在使用这种方法时,由于切伦科夫各向异性,必须进行角度校正。我们测试了几种切伦科夫光源到相机的距离,以确定其对计算剂量分布与参考值偏差的影响。得出的基于切伦科夫的结果与闪烁结果之间的平均相对差异从-1.6%到-11%不等。据观察,切伦科夫光源到相机距离的增加会减小切伦科夫光学信号与剂量之间的差异。这就降低了在较远距离(4 米及以上)进行角度校正的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of signal source to camera distance in Cherenkov dosimetry using polarized imaging
As Cherenkov emissions are related to dose, they can be used as signal for dosimetric purposes using polarized imaging. However, when using this method, angular corrections must be applied because of Cherenkov anisotropy. Several Cherenkov light source-to-camera distances were tested to characterize its impact on the deviations from reference values of the calculated dose distributions. Average relative differences ranging from −1.6% to −11% between Cherenkov-based results and scintillation results were extracted. It is observed that an increase in Cherenkov light source-to-camera distance decreases the difference between the Cherenkov optical signal and the dose. This reduces the importance of angular corrections at higher distances (4 m and beyond).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信