Sandie Eiras, Gregorios Bolgouras, Christos Panayiotou, Zacharias Alexandrou, C. Papakostidis
{"title":"孤立性、粉碎性、双关节梯形骨折的手术治疗:病例报告和文献综述","authors":"Sandie Eiras, Gregorios Bolgouras, Christos Panayiotou, Zacharias Alexandrou, C. Papakostidis","doi":"10.1055/s-0044-1788639","DOIUrl":null,"url":null,"abstract":"\n Background Isolated, highly comminuted trapezium fractures are extremely rare. While they can be initially diagnosed with plain radiographs, a computed tomography scan of the wrist will more clearly reveal the fracture details and aid in appropriate preoperative planning. Restoration of the fracture with a congruent reduction of the adjacent joints is mandatory for a favorable prognosis.\n Case Description A case of a highly comminuted, biarticular, trapezium fracture in a young male patient that was treated operatively with open reduction and internal fixation (ORIF) with a cannulated miniscrew and an additional Kirschner wire (K-wire) is presented. Restoration of a decent intra-articular congruity of the trapezium with both the base of the first metacarpal distally and the scaphoid bone proximally ensured a favorable outcome.\n Literature Review Various operative techniques are presented in current literature, encompassing ORIF with screws and K-wires, closed reduction and percutaneous fixation with K-wires, mini-external fixation, button fixation, and arthroscopically assisted percutaneous fixation. A favorable prognosis is documented in cases where a congruous reduction of the fracture was achieved and maintained throughout the healing period.\n Clinical Relevance We feel that a formal ORIF is the procedure of choice for highly comminuted trapezium fractures, as they are not easily amenable to accurate reduction by means of closed methods.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Operative Treatment of an Isolated, Comminuted, Biarticular Trapezium Fracture: A Case Report and Review of the Literature\",\"authors\":\"Sandie Eiras, Gregorios Bolgouras, Christos Panayiotou, Zacharias Alexandrou, C. Papakostidis\",\"doi\":\"10.1055/s-0044-1788639\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Background Isolated, highly comminuted trapezium fractures are extremely rare. While they can be initially diagnosed with plain radiographs, a computed tomography scan of the wrist will more clearly reveal the fracture details and aid in appropriate preoperative planning. Restoration of the fracture with a congruent reduction of the adjacent joints is mandatory for a favorable prognosis.\\n Case Description A case of a highly comminuted, biarticular, trapezium fracture in a young male patient that was treated operatively with open reduction and internal fixation (ORIF) with a cannulated miniscrew and an additional Kirschner wire (K-wire) is presented. Restoration of a decent intra-articular congruity of the trapezium with both the base of the first metacarpal distally and the scaphoid bone proximally ensured a favorable outcome.\\n Literature Review Various operative techniques are presented in current literature, encompassing ORIF with screws and K-wires, closed reduction and percutaneous fixation with K-wires, mini-external fixation, button fixation, and arthroscopically assisted percutaneous fixation. A favorable prognosis is documented in cases where a congruous reduction of the fracture was achieved and maintained throughout the healing period.\\n Clinical Relevance We feel that a formal ORIF is the procedure of choice for highly comminuted trapezium fractures, as they are not easily amenable to accurate reduction by means of closed methods.\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0,\"publicationDate\":\"2024-07-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0044-1788639\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0044-1788639","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
背景 孤立、高度粉碎性梯形骨折极为罕见。虽然可通过普通X光片进行初步诊断,但腕部计算机断层扫描能更清楚地显示骨折细节,有助于制定适当的术前计划。为了获得良好的预后,必须对骨折进行复位,并对相邻关节进行一致的复位。病例描述 本病例是一名年轻男性患者的高度粉碎性、双关节、梯形骨折,采用切开复位和内固定术(ORIF)治疗,使用插管微型螺钉和额外的 Kirschner 线(K 线)。该手术恢复了斜方肌与第一掌骨远端基底和肩胛骨近端的关节内一致性,确保了良好的治疗效果。文献综述 目前的文献介绍了多种手术技术,包括使用螺钉和 K 型钢丝的 ORIF、闭合复位和 K 型钢丝经皮固定、迷你外固定、纽扣固定和关节镜辅助经皮固定。有资料显示,在实现骨折整齐复位并保持整个愈合期的病例中,预后良好。临床意义 我们认为,对于高度粉碎性斜方肌骨折,正式的闭合复位术是首选手术,因为这些骨折不易通过闭合方法进行精确复位。
Operative Treatment of an Isolated, Comminuted, Biarticular Trapezium Fracture: A Case Report and Review of the Literature
Background Isolated, highly comminuted trapezium fractures are extremely rare. While they can be initially diagnosed with plain radiographs, a computed tomography scan of the wrist will more clearly reveal the fracture details and aid in appropriate preoperative planning. Restoration of the fracture with a congruent reduction of the adjacent joints is mandatory for a favorable prognosis.
Case Description A case of a highly comminuted, biarticular, trapezium fracture in a young male patient that was treated operatively with open reduction and internal fixation (ORIF) with a cannulated miniscrew and an additional Kirschner wire (K-wire) is presented. Restoration of a decent intra-articular congruity of the trapezium with both the base of the first metacarpal distally and the scaphoid bone proximally ensured a favorable outcome.
Literature Review Various operative techniques are presented in current literature, encompassing ORIF with screws and K-wires, closed reduction and percutaneous fixation with K-wires, mini-external fixation, button fixation, and arthroscopically assisted percutaneous fixation. A favorable prognosis is documented in cases where a congruous reduction of the fracture was achieved and maintained throughout the healing period.
Clinical Relevance We feel that a formal ORIF is the procedure of choice for highly comminuted trapezium fractures, as they are not easily amenable to accurate reduction by means of closed methods.