Kang Kim, Byoung-kyu Jeon, Andrew Ward, U. Mertyurek, Matthew Jessee, W. Wieselquist
{"title":"利用ENDF/B-VII.1 AMPX 56组库验证SCALE/Polaris-PARCS代码程序:压水堆","authors":"Kang Kim, Byoung-kyu Jeon, Andrew Ward, U. Mertyurek, Matthew Jessee, W. Wieselquist","doi":"10.3390/jne5030017","DOIUrl":null,"url":null,"abstract":"This study was conducted to validate the SCALE/Polaris v6.3.0–PARCS v3.4.2 code procedure with the Evaluated Nuclear Data File (ENDF)/B-VII.1 AMPX 56-group library for pressurized water reactor (PWR) analysis, by comparing simulated results with measured data for critical experiments and operating PWRs. Uncertainties of the SCALE/Polaris–PARCS code procedure for PWR analysis were evaluated in the validation for the PWR key nuclear parameters such as critical boron concentrations, reactivity, control bank work, temperature coefficients, and pin and assembly power peaking factors.","PeriodicalId":512967,"journal":{"name":"Journal of Nuclear Engineering","volume":"45 6","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of the SCALE/Polaris−PARCS Code Procedure with the ENDF/B-VII.1 AMPX 56-Group Library: Pressurized Water Reactor\",\"authors\":\"Kang Kim, Byoung-kyu Jeon, Andrew Ward, U. Mertyurek, Matthew Jessee, W. Wieselquist\",\"doi\":\"10.3390/jne5030017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study was conducted to validate the SCALE/Polaris v6.3.0–PARCS v3.4.2 code procedure with the Evaluated Nuclear Data File (ENDF)/B-VII.1 AMPX 56-group library for pressurized water reactor (PWR) analysis, by comparing simulated results with measured data for critical experiments and operating PWRs. Uncertainties of the SCALE/Polaris–PARCS code procedure for PWR analysis were evaluated in the validation for the PWR key nuclear parameters such as critical boron concentrations, reactivity, control bank work, temperature coefficients, and pin and assembly power peaking factors.\",\"PeriodicalId\":512967,\"journal\":{\"name\":\"Journal of Nuclear Engineering\",\"volume\":\"45 6\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Nuclear Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/jne5030017\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nuclear Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/jne5030017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Validation of the SCALE/Polaris−PARCS Code Procedure with the ENDF/B-VII.1 AMPX 56-Group Library: Pressurized Water Reactor
This study was conducted to validate the SCALE/Polaris v6.3.0–PARCS v3.4.2 code procedure with the Evaluated Nuclear Data File (ENDF)/B-VII.1 AMPX 56-group library for pressurized water reactor (PWR) analysis, by comparing simulated results with measured data for critical experiments and operating PWRs. Uncertainties of the SCALE/Polaris–PARCS code procedure for PWR analysis were evaluated in the validation for the PWR key nuclear parameters such as critical boron concentrations, reactivity, control bank work, temperature coefficients, and pin and assembly power peaking factors.