在普通病房为气管造口插管患者使用自动吸痰装置:病例报告

Sehyeon Yu, Hanyoung Lee, Jae-Myeong Lee
{"title":"在普通病房为气管造口插管患者使用自动吸痰装置:病例报告","authors":"Sehyeon Yu, Hanyoung Lee, Jae-Myeong Lee","doi":"10.17479/jacs.2024.14.2.71","DOIUrl":null,"url":null,"abstract":"The A-1000 (Elmeca, Co. Ltd., Seoul, Korea) electrical automatic airway suction device, was designed to operate as a customizable repeated closed suction device. It can be used for patients with intubation or tracheostomy tubes. This is the first recorded case of the use of the A-1000 in a general ward patient with a tracheostomy tube. A 91-year-old man presented having attempted suicide by hanging and was admitted to this institution. Although extubation was performed in the intensive care unit, the patient required 2 reintubations. The tracheostomy was performed, and the A-1000 was applied. After weaning from mechanical ventilation, the patient was transferred to the General Ward with a tracheostomy tube in place for effective removal of sputum by the A-1000. The tracheostomy tube was successfully removed, and the patient was discharged. The effectiveness and safety of the A-1000 needs further study by expanding the applications of this device.","PeriodicalId":34662,"journal":{"name":"Journal of Acute Care Surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of an Automatic Suction Device to a Patient with A Tracheostomy Tube in the General Ward: A Case Report\",\"authors\":\"Sehyeon Yu, Hanyoung Lee, Jae-Myeong Lee\",\"doi\":\"10.17479/jacs.2024.14.2.71\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The A-1000 (Elmeca, Co. Ltd., Seoul, Korea) electrical automatic airway suction device, was designed to operate as a customizable repeated closed suction device. It can be used for patients with intubation or tracheostomy tubes. This is the first recorded case of the use of the A-1000 in a general ward patient with a tracheostomy tube. A 91-year-old man presented having attempted suicide by hanging and was admitted to this institution. Although extubation was performed in the intensive care unit, the patient required 2 reintubations. The tracheostomy was performed, and the A-1000 was applied. After weaning from mechanical ventilation, the patient was transferred to the General Ward with a tracheostomy tube in place for effective removal of sputum by the A-1000. The tracheostomy tube was successfully removed, and the patient was discharged. The effectiveness and safety of the A-1000 needs further study by expanding the applications of this device.\",\"PeriodicalId\":34662,\"journal\":{\"name\":\"Journal of Acute Care Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Acute Care Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17479/jacs.2024.14.2.71\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Acute Care Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17479/jacs.2024.14.2.71","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

A-1000 (Elmeca 有限公司,韩国首尔)电动自动气道吸引装置设计为可定制的重复封闭式吸引装置。它可用于插管或气管切开的患者。这是首例将 A-1000 用于带气管造口管的普通病房患者的记录。一名 91 岁的老人企图上吊自杀,被送进了这家医院。虽然在重症监护室进行了拔管,但患者需要两次重新插管。患者接受了气管切开术,并使用了 A-1000 通气导管。从机械通气断气后,患者被转到普通病房,并插上气管造口管,以便用 A-1000 有效清除痰液。气管造口管被成功拔除,病人也已出院。A-1000 的有效性和安全性需要通过扩大该设备的应用范围来进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of an Automatic Suction Device to a Patient with A Tracheostomy Tube in the General Ward: A Case Report
The A-1000 (Elmeca, Co. Ltd., Seoul, Korea) electrical automatic airway suction device, was designed to operate as a customizable repeated closed suction device. It can be used for patients with intubation or tracheostomy tubes. This is the first recorded case of the use of the A-1000 in a general ward patient with a tracheostomy tube. A 91-year-old man presented having attempted suicide by hanging and was admitted to this institution. Although extubation was performed in the intensive care unit, the patient required 2 reintubations. The tracheostomy was performed, and the A-1000 was applied. After weaning from mechanical ventilation, the patient was transferred to the General Ward with a tracheostomy tube in place for effective removal of sputum by the A-1000. The tracheostomy tube was successfully removed, and the patient was discharged. The effectiveness and safety of the A-1000 needs further study by expanding the applications of this device.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
16
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信