使用新的改良基底顶点导联法评估马的血管收缩力指数和心电图参数。

IF 1.7 Q2 AGRICULTURE, DAIRY & ANIMAL SCIENCE
Veterinary World Pub Date : 2024-06-01 Epub Date: 2024-06-28 DOI:10.14202/vetworld.2024.1385-1390
Theerapong Pontaema, Pongphol Pongthaisong, Wootichai Kenchaiwong, Chayanon Chompoosan, Wichaporn Lerdweeraphon
{"title":"使用新的改良基底顶点导联法评估马的血管收缩力指数和心电图参数。","authors":"Theerapong Pontaema, Pongphol Pongthaisong, Wootichai Kenchaiwong, Chayanon Chompoosan, Wichaporn Lerdweeraphon","doi":"10.14202/vetworld.2024.1385-1390","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aim: </strong>Vasovagal tonus index (VVTI) serves as a straightforward assessment tool for autonomic function during both physiological and pathological conditions, including pregnancy, in horses. Obtaining VVTI through a modified base apex lead system could be a practical and comfortable solution. In this study, we assessed VVTI in horses with respect to training status and electrocardiographic measurements utilizing a novel modified base apex lead technique.</p><p><strong>Materials and methods: </strong>A total of 12 Thai native crossbred horses and 12 Arabian horses, all free of cardiac abnormalities, were enrolled in the study. Animals underwent electrocardiogram (ECG) and VVTI using both the base-apex lead method and its modified version. 25 mm/s and 10 mm/mV ECG recordings provided standard bipolar limb leads. The amplitudes and durations of P waves, QRS complexes, PR interval, QT interval, and T duration were assessed. The T wave's shape was examined. Each recording's R-R interval was utilized to assess heart rate. Twenty consecutive beats were used to compute the variability of heart rate (VVTI).</p><p><strong>Results: </strong>The P wave amplitude was the only significant difference (p < 0.05) between the base apex lead method and the modified base apex lead method, with no variations in heart rate, P duration, PR interval, T duration, and QRS duration and amplitude. Both methods showed mainly biphasic T wave patterns. The VVTI values of all horses did not differ significantly between the base apex and modified base apex methods. There was no significant difference in VVTI between Thai crossbred horses and Arabian horses in either method.</p><p><strong>Conclusion: </strong>This study provided the first evidence that VVTI can be evaluated using the modified base apex lead system and may be useful for cardiovascular function monitoring in horses.</p>","PeriodicalId":23587,"journal":{"name":"Veterinary World","volume":"17 6","pages":"1385-1390"},"PeriodicalIF":1.7000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11283595/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of vasovagal tonus index and electrocardiographic parameters in horses using a new modified base apex lead method.\",\"authors\":\"Theerapong Pontaema, Pongphol Pongthaisong, Wootichai Kenchaiwong, Chayanon Chompoosan, Wichaporn Lerdweeraphon\",\"doi\":\"10.14202/vetworld.2024.1385-1390\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and aim: </strong>Vasovagal tonus index (VVTI) serves as a straightforward assessment tool for autonomic function during both physiological and pathological conditions, including pregnancy, in horses. Obtaining VVTI through a modified base apex lead system could be a practical and comfortable solution. In this study, we assessed VVTI in horses with respect to training status and electrocardiographic measurements utilizing a novel modified base apex lead technique.</p><p><strong>Materials and methods: </strong>A total of 12 Thai native crossbred horses and 12 Arabian horses, all free of cardiac abnormalities, were enrolled in the study. Animals underwent electrocardiogram (ECG) and VVTI using both the base-apex lead method and its modified version. 25 mm/s and 10 mm/mV ECG recordings provided standard bipolar limb leads. The amplitudes and durations of P waves, QRS complexes, PR interval, QT interval, and T duration were assessed. The T wave's shape was examined. Each recording's R-R interval was utilized to assess heart rate. Twenty consecutive beats were used to compute the variability of heart rate (VVTI).</p><p><strong>Results: </strong>The P wave amplitude was the only significant difference (p < 0.05) between the base apex lead method and the modified base apex lead method, with no variations in heart rate, P duration, PR interval, T duration, and QRS duration and amplitude. Both methods showed mainly biphasic T wave patterns. The VVTI values of all horses did not differ significantly between the base apex and modified base apex methods. There was no significant difference in VVTI between Thai crossbred horses and Arabian horses in either method.</p><p><strong>Conclusion: </strong>This study provided the first evidence that VVTI can be evaluated using the modified base apex lead system and may be useful for cardiovascular function monitoring in horses.</p>\",\"PeriodicalId\":23587,\"journal\":{\"name\":\"Veterinary World\",\"volume\":\"17 6\",\"pages\":\"1385-1390\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11283595/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary World\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14202/vetworld.2024.1385-1390\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"AGRICULTURE, DAIRY & ANIMAL SCIENCE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary World","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14202/vetworld.2024.1385-1390","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"AGRICULTURE, DAIRY & ANIMAL SCIENCE","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:血管迷走神经张力指数(VVTI)是评估马匹在生理和病理状态(包括怀孕)下自律神经功能的直接工具。通过改良的基底顶点导联系统获得 VVTI 可能是一种实用而舒适的解决方案。在本研究中,我们利用一种新型改良的基底顶点导联技术,评估了马匹的 VVTI 与训练状态和心电图测量的关系:研究对象包括 12 匹泰国本土杂交马和 12 匹阿拉伯马,它们均无心脏畸形。使用基底-心尖导联法及其改进版进行心电图(ECG)和 VVTI 检查。25 mm/s 和 10 mm/mV 的心电图记录提供了标准的双极肢体导联。对 P 波、QRS 波群、PR 间期、QT 间期和 T 波持续时间的振幅和持续时间进行了评估。还检查了 T 波的形状。利用每次记录的 R-R 间期评估心率。连续 20 次心搏用于计算心率变异性(VVTI):结果:P 波振幅是基底顶点导联法和改良基底顶点导联法之间唯一的显著差异(p < 0.05),心率、P 波持续时间、PR 间期、T 波持续时间、QRS 波持续时间和振幅均无差异。两种方法都主要显示双相 T 波形态。所有马匹的 VVTI 值在基底顶点法和改良基底顶点法之间没有显著差异。无论采用哪种方法,泰国杂交马和阿拉伯马的 VVTI 值均无明显差异:本研究首次证明了使用改良的基底顶点导联系统可以评估 VVTI,并可用于监测马匹的心血管功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of vasovagal tonus index and electrocardiographic parameters in horses using a new modified base apex lead method.

Background and aim: Vasovagal tonus index (VVTI) serves as a straightforward assessment tool for autonomic function during both physiological and pathological conditions, including pregnancy, in horses. Obtaining VVTI through a modified base apex lead system could be a practical and comfortable solution. In this study, we assessed VVTI in horses with respect to training status and electrocardiographic measurements utilizing a novel modified base apex lead technique.

Materials and methods: A total of 12 Thai native crossbred horses and 12 Arabian horses, all free of cardiac abnormalities, were enrolled in the study. Animals underwent electrocardiogram (ECG) and VVTI using both the base-apex lead method and its modified version. 25 mm/s and 10 mm/mV ECG recordings provided standard bipolar limb leads. The amplitudes and durations of P waves, QRS complexes, PR interval, QT interval, and T duration were assessed. The T wave's shape was examined. Each recording's R-R interval was utilized to assess heart rate. Twenty consecutive beats were used to compute the variability of heart rate (VVTI).

Results: The P wave amplitude was the only significant difference (p < 0.05) between the base apex lead method and the modified base apex lead method, with no variations in heart rate, P duration, PR interval, T duration, and QRS duration and amplitude. Both methods showed mainly biphasic T wave patterns. The VVTI values of all horses did not differ significantly between the base apex and modified base apex methods. There was no significant difference in VVTI between Thai crossbred horses and Arabian horses in either method.

Conclusion: This study provided the first evidence that VVTI can be evaluated using the modified base apex lead system and may be useful for cardiovascular function monitoring in horses.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Veterinary World
Veterinary World Multiple-
CiteScore
3.60
自引率
12.50%
发文量
317
审稿时长
16 weeks
期刊介绍: Veterinary World publishes high quality papers focusing on Veterinary and Animal Science. The fields of study are bacteriology, parasitology, pathology, virology, immunology, mycology, public health, biotechnology, meat science, fish diseases, nutrition, gynecology, genetics, wildlife, laboratory animals, animal models of human infections, prion diseases and epidemiology. Studies on zoonotic and emerging infections are highly appreciated. Review articles are highly appreciated. All articles published by Veterinary World are made freely and permanently accessible online. All articles to Veterinary World are posted online immediately as they are ready for publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信