Naoya Tada, Naoto Tamai, Mamoru Ito, Mai Fukuda, Toshiki Futakuchi, Hideka Horiuchi, Masakuni Kobayashi, Kazuki Sumiyama
{"title":"带锚刺的新型可再开放夹有助于结直肠内镜黏膜下剥离术后黏膜缺损的闭合:试点可行性研究(附视频)。","authors":"Naoya Tada, Naoto Tamai, Mamoru Ito, Mai Fukuda, Toshiki Futakuchi, Hideka Horiuchi, Masakuni Kobayashi, Kazuki Sumiyama","doi":"10.1111/den.14891","DOIUrl":null,"url":null,"abstract":"<p>Closure of mucosal defects following colorectal endoscopic submucosal dissection (C-ESD) is often performed to prevent post-C-ESD adverse events. However, large mucosal defect closure using conventional clips remains technically challenging. Here, we evaluated the feasibility of the novel endoclip with anchor prongs, called the MANTIS Clip (Boston Scientific, Tokyo, Japan), for mucosal defect closure after C-ESD. This high-volume retrospective study was conducted at a single center. From March until December 2023, consecutive patients who underwent post-C-ESD mucosal defect closure using MANTIS Clip to achieve complete closure were enrolled. Patient clinical characteristics and outcomes were evaluated. Closure of the mucosal defect using the MANTIS Clip was attempted following C-ESD in 32 lesions. The median sizes of the resection specimens and the tumors were 32 mm (range, 17–100 mm) and 23.5 mm (range, 5–96 mm), respectively. The lesions were distributed between the cecum, ascending, transverse, descending, sigmoid, and rectum. Complete closure was achieved in 96.9% of cases (31/32). All lesions up to 61 mm in defect size were completely closed. The median closure time was 7.9 (range, 3.3–18.0) min. The median numbers of MANTIS Clip and additional conventional clips were 3 (range, 1–4) and 5 (range, 1–11), respectively. No adverse events associated with closure, post-ESD bleeding, and delayed perforation occurred. MANTIS Clip closure for large post-C-ESD mucosal defects was found to be feasible and reliable with a high complete closure rate and a short procedure time.</p>","PeriodicalId":159,"journal":{"name":"Digestive Endoscopy","volume":"36 10","pages":"1164-1170"},"PeriodicalIF":5.0000,"publicationDate":"2024-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Novel reopenable clip with anchor prongs facilitates mucosal defect closure after colorectal endoscopic submucosal dissection: Pilot feasibility study (with video)\",\"authors\":\"Naoya Tada, Naoto Tamai, Mamoru Ito, Mai Fukuda, Toshiki Futakuchi, Hideka Horiuchi, Masakuni Kobayashi, Kazuki Sumiyama\",\"doi\":\"10.1111/den.14891\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Closure of mucosal defects following colorectal endoscopic submucosal dissection (C-ESD) is often performed to prevent post-C-ESD adverse events. However, large mucosal defect closure using conventional clips remains technically challenging. Here, we evaluated the feasibility of the novel endoclip with anchor prongs, called the MANTIS Clip (Boston Scientific, Tokyo, Japan), for mucosal defect closure after C-ESD. This high-volume retrospective study was conducted at a single center. From March until December 2023, consecutive patients who underwent post-C-ESD mucosal defect closure using MANTIS Clip to achieve complete closure were enrolled. Patient clinical characteristics and outcomes were evaluated. Closure of the mucosal defect using the MANTIS Clip was attempted following C-ESD in 32 lesions. The median sizes of the resection specimens and the tumors were 32 mm (range, 17–100 mm) and 23.5 mm (range, 5–96 mm), respectively. The lesions were distributed between the cecum, ascending, transverse, descending, sigmoid, and rectum. Complete closure was achieved in 96.9% of cases (31/32). All lesions up to 61 mm in defect size were completely closed. The median closure time was 7.9 (range, 3.3–18.0) min. The median numbers of MANTIS Clip and additional conventional clips were 3 (range, 1–4) and 5 (range, 1–11), respectively. No adverse events associated with closure, post-ESD bleeding, and delayed perforation occurred. MANTIS Clip closure for large post-C-ESD mucosal defects was found to be feasible and reliable with a high complete closure rate and a short procedure time.</p>\",\"PeriodicalId\":159,\"journal\":{\"name\":\"Digestive Endoscopy\",\"volume\":\"36 10\",\"pages\":\"1164-1170\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2024-07-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digestive Endoscopy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/den.14891\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestive Endoscopy","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/den.14891","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
Novel reopenable clip with anchor prongs facilitates mucosal defect closure after colorectal endoscopic submucosal dissection: Pilot feasibility study (with video)
Closure of mucosal defects following colorectal endoscopic submucosal dissection (C-ESD) is often performed to prevent post-C-ESD adverse events. However, large mucosal defect closure using conventional clips remains technically challenging. Here, we evaluated the feasibility of the novel endoclip with anchor prongs, called the MANTIS Clip (Boston Scientific, Tokyo, Japan), for mucosal defect closure after C-ESD. This high-volume retrospective study was conducted at a single center. From March until December 2023, consecutive patients who underwent post-C-ESD mucosal defect closure using MANTIS Clip to achieve complete closure were enrolled. Patient clinical characteristics and outcomes were evaluated. Closure of the mucosal defect using the MANTIS Clip was attempted following C-ESD in 32 lesions. The median sizes of the resection specimens and the tumors were 32 mm (range, 17–100 mm) and 23.5 mm (range, 5–96 mm), respectively. The lesions were distributed between the cecum, ascending, transverse, descending, sigmoid, and rectum. Complete closure was achieved in 96.9% of cases (31/32). All lesions up to 61 mm in defect size were completely closed. The median closure time was 7.9 (range, 3.3–18.0) min. The median numbers of MANTIS Clip and additional conventional clips were 3 (range, 1–4) and 5 (range, 1–11), respectively. No adverse events associated with closure, post-ESD bleeding, and delayed perforation occurred. MANTIS Clip closure for large post-C-ESD mucosal defects was found to be feasible and reliable with a high complete closure rate and a short procedure time.
期刊介绍:
Digestive Endoscopy (DEN) is the official journal of the Japan Gastroenterological Endoscopy Society, the Asian Pacific Society for Digestive Endoscopy and the World Endoscopy Organization. Digestive Endoscopy serves as a medium for presenting original articles that offer significant contributions to knowledge in the broad field of endoscopy. The Journal also includes Reviews, Original Articles, How I Do It, Case Reports (only of exceptional interest and novelty are accepted), Letters, Techniques and Images, abstracts and news items that may be of interest to endoscopists.