使用 3D 打印机制作的立体光刻模型随时间发生的尺寸变化。

IF 1.9 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Odontology Pub Date : 2025-01-01 Epub Date: 2024-07-29 DOI:10.1007/s10266-024-00972-8
Shohei Suzuki, Rina Suzuki, Munetsugu Seto, Kazuhiko Hiroyasu, Shin Ogura, Kazuhiko Ueda
{"title":"使用 3D 打印机制作的立体光刻模型随时间发生的尺寸变化。","authors":"Shohei Suzuki, Rina Suzuki, Munetsugu Seto, Kazuhiko Hiroyasu, Shin Ogura, Kazuhiko Ueda","doi":"10.1007/s10266-024-00972-8","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to ascertain the effects of the shape of stereolithographic models fabricated with a three-dimensional (3D) printer and the use of different types of liquid resin on the dimensional changes of these models over time, to obtain valuable information for determining the period for which such models can be used following fabrication. Stereolithography models with the shape of a large truncated cone or a small truncated cone were fabricated using liquid resin as surgical guides (Group G) or master casts (Group M). (four groups in total, each n = 11). The shapes of all experimental specimens were measured immediately after fabrication and 1 day, 1 week, 2 weeks, 3 weeks, 4 weeks, 2 months, 3 months, 6 months, 1 year, and 1.5 years later. The shape data collected immediately after fabrication were taken as baseline data, and the dimensional changes over time at each timepoint were calculated. No significant change from 1 day to 1 year after fabrication was observed in any of the groups, but the change after 1.5 years was significantly larger than the changes at the other timepoints (p < 0.001). Significantly larger changes were evident in Group M than in Group G at all timepoints (p < 0.001). These results suggested that, from the viewpoint of dimensional stability over time, stereolithographic models should be used within 1 year of fabrication, and that the type of liquid resin used for stereolithographic model fabrication may affect how its dimensions change over time.</p>","PeriodicalId":19390,"journal":{"name":"Odontology","volume":" ","pages":"274-282"},"PeriodicalIF":1.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dimensional changes over time in stereolithographic models fabricated with a 3D printer.\",\"authors\":\"Shohei Suzuki, Rina Suzuki, Munetsugu Seto, Kazuhiko Hiroyasu, Shin Ogura, Kazuhiko Ueda\",\"doi\":\"10.1007/s10266-024-00972-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to ascertain the effects of the shape of stereolithographic models fabricated with a three-dimensional (3D) printer and the use of different types of liquid resin on the dimensional changes of these models over time, to obtain valuable information for determining the period for which such models can be used following fabrication. Stereolithography models with the shape of a large truncated cone or a small truncated cone were fabricated using liquid resin as surgical guides (Group G) or master casts (Group M). (four groups in total, each n = 11). The shapes of all experimental specimens were measured immediately after fabrication and 1 day, 1 week, 2 weeks, 3 weeks, 4 weeks, 2 months, 3 months, 6 months, 1 year, and 1.5 years later. The shape data collected immediately after fabrication were taken as baseline data, and the dimensional changes over time at each timepoint were calculated. No significant change from 1 day to 1 year after fabrication was observed in any of the groups, but the change after 1.5 years was significantly larger than the changes at the other timepoints (p < 0.001). Significantly larger changes were evident in Group M than in Group G at all timepoints (p < 0.001). These results suggested that, from the viewpoint of dimensional stability over time, stereolithographic models should be used within 1 year of fabrication, and that the type of liquid resin used for stereolithographic model fabrication may affect how its dimensions change over time.</p>\",\"PeriodicalId\":19390,\"journal\":{\"name\":\"Odontology\",\"volume\":\" \",\"pages\":\"274-282\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Odontology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10266-024-00972-8\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Odontology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10266-024-00972-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/29 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在确定用三维(3D)打印机制作的立体光刻模型的形状以及使用不同类型的液体树脂对这些模型随时间推移而发生的尺寸变化的影响,从而获得有价值的信息,以确定这些模型在制作完成后的使用期限。使用液体树脂作为手术导板(G 组)或母模(M 组),制作了大截顶锥或小截顶锥形状的立体光刻模型。(共四组,每组 n = 11)。所有实验样本的形状均在制作完成后立即进行测量,并在 1 天、1 周、2 周、3 周、4 周、2 个月、3 个月、6 个月、1 年和 1.5 年后进行测量。制作完成后立即采集的形状数据作为基线数据,并计算每个时间点随时间的尺寸变化。从制作后 1 天到 1 年,各组都没有观察到明显的变化,但 1.5 年后的变化明显大于其他时间点的变化(p<0.05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Dimensional changes over time in stereolithographic models fabricated with a 3D printer.

Dimensional changes over time in stereolithographic models fabricated with a 3D printer.

This study aimed to ascertain the effects of the shape of stereolithographic models fabricated with a three-dimensional (3D) printer and the use of different types of liquid resin on the dimensional changes of these models over time, to obtain valuable information for determining the period for which such models can be used following fabrication. Stereolithography models with the shape of a large truncated cone or a small truncated cone were fabricated using liquid resin as surgical guides (Group G) or master casts (Group M). (four groups in total, each n = 11). The shapes of all experimental specimens were measured immediately after fabrication and 1 day, 1 week, 2 weeks, 3 weeks, 4 weeks, 2 months, 3 months, 6 months, 1 year, and 1.5 years later. The shape data collected immediately after fabrication were taken as baseline data, and the dimensional changes over time at each timepoint were calculated. No significant change from 1 day to 1 year after fabrication was observed in any of the groups, but the change after 1.5 years was significantly larger than the changes at the other timepoints (p < 0.001). Significantly larger changes were evident in Group M than in Group G at all timepoints (p < 0.001). These results suggested that, from the viewpoint of dimensional stability over time, stereolithographic models should be used within 1 year of fabrication, and that the type of liquid resin used for stereolithographic model fabrication may affect how its dimensions change over time.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Odontology
Odontology 医学-牙科与口腔外科
CiteScore
5.30
自引率
4.00%
发文量
91
审稿时长
>12 weeks
期刊介绍: The Journal Odontology covers all disciplines involved in the fields of dentistry and craniofacial research, including molecular studies related to oral health and disease. Peer-reviewed articles cover topics ranging from research on human dental pulp, to comparisons of analgesics in surgery, to analysis of biofilm properties of dental plaque.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信