Naveen Kumar Challa, Deepthi Jagadeeswaran, Saif Hasan Alrasheed, Abd Elaziz Mohamed Elmadina, Waleed Alghamdi
{"title":"一大批南印度儿童的角膜直径和睑裂高度的标准数据。","authors":"Naveen Kumar Challa, Deepthi Jagadeeswaran, Saif Hasan Alrasheed, Abd Elaziz Mohamed Elmadina, Waleed Alghamdi","doi":"10.25122/jml-2023-0535","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to establish the normative data of horizontal visible iris diameter (HVID), vertical visible iris diameter (VVID), and palpebral fissure height (PFH) in a cohort of South Indian children. The study included 1,234 children from six schools of different regions of Tamil Nadu state, India. HVID, VVID, and PFH were measured using a simple millimeter ruler by three optometrists. Based on their age, the children were divided into three groups: preprimary school children (4-5 years), primary school children (6-10 years), and high school children (11-15 years). Mean age was 4.49 ± 0.50 years, 8.00 ± 1.41 years, and 12.87 ± 1.42 years in the three groups, respectively. Mean HVID was 10.45 mm, 10.54 mm, and 10.73 mm, respectively. Mean VVID was 9.18 mm, 9.32 mm, and 9.57 mm, respectively. Similarly, mean PFH was 8.15 mm, 8.30 mm, and 8.52 mm, respectively. There was a significant difference in HVID, VVID, and PFH among the three age groups (<i>P</i> ≤ 0.001), as well as among male and female children in the 6-10 years age group (<i>P</i> ≤ 0.05) but not in the other groups. Intraclass correlation coefficient values (0.78-0.95) show good agreement among the three optometrists for all parameters. The normal range of HVID, VVID, and PFH presented in the current study can help practitioners in the diagnosis of corneal disorders, serve as a basis for the design of contact lenses, and enable accurate intraocular lens power calculations for South Indian children.</p>","PeriodicalId":16386,"journal":{"name":"Journal of Medicine and Life","volume":"17 4","pages":"406-411"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11282901/pdf/","citationCount":"0","resultStr":"{\"title\":\"Normative data of corneal diameter and palpebral fissure height in a large cohort of South Indian children.\",\"authors\":\"Naveen Kumar Challa, Deepthi Jagadeeswaran, Saif Hasan Alrasheed, Abd Elaziz Mohamed Elmadina, Waleed Alghamdi\",\"doi\":\"10.25122/jml-2023-0535\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this study was to establish the normative data of horizontal visible iris diameter (HVID), vertical visible iris diameter (VVID), and palpebral fissure height (PFH) in a cohort of South Indian children. The study included 1,234 children from six schools of different regions of Tamil Nadu state, India. HVID, VVID, and PFH were measured using a simple millimeter ruler by three optometrists. Based on their age, the children were divided into three groups: preprimary school children (4-5 years), primary school children (6-10 years), and high school children (11-15 years). Mean age was 4.49 ± 0.50 years, 8.00 ± 1.41 years, and 12.87 ± 1.42 years in the three groups, respectively. Mean HVID was 10.45 mm, 10.54 mm, and 10.73 mm, respectively. Mean VVID was 9.18 mm, 9.32 mm, and 9.57 mm, respectively. Similarly, mean PFH was 8.15 mm, 8.30 mm, and 8.52 mm, respectively. There was a significant difference in HVID, VVID, and PFH among the three age groups (<i>P</i> ≤ 0.001), as well as among male and female children in the 6-10 years age group (<i>P</i> ≤ 0.05) but not in the other groups. Intraclass correlation coefficient values (0.78-0.95) show good agreement among the three optometrists for all parameters. The normal range of HVID, VVID, and PFH presented in the current study can help practitioners in the diagnosis of corneal disorders, serve as a basis for the design of contact lenses, and enable accurate intraocular lens power calculations for South Indian children.</p>\",\"PeriodicalId\":16386,\"journal\":{\"name\":\"Journal of Medicine and Life\",\"volume\":\"17 4\",\"pages\":\"406-411\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11282901/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medicine and Life\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25122/jml-2023-0535\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medicine and Life","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25122/jml-2023-0535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Normative data of corneal diameter and palpebral fissure height in a large cohort of South Indian children.
The purpose of this study was to establish the normative data of horizontal visible iris diameter (HVID), vertical visible iris diameter (VVID), and palpebral fissure height (PFH) in a cohort of South Indian children. The study included 1,234 children from six schools of different regions of Tamil Nadu state, India. HVID, VVID, and PFH were measured using a simple millimeter ruler by three optometrists. Based on their age, the children were divided into three groups: preprimary school children (4-5 years), primary school children (6-10 years), and high school children (11-15 years). Mean age was 4.49 ± 0.50 years, 8.00 ± 1.41 years, and 12.87 ± 1.42 years in the three groups, respectively. Mean HVID was 10.45 mm, 10.54 mm, and 10.73 mm, respectively. Mean VVID was 9.18 mm, 9.32 mm, and 9.57 mm, respectively. Similarly, mean PFH was 8.15 mm, 8.30 mm, and 8.52 mm, respectively. There was a significant difference in HVID, VVID, and PFH among the three age groups (P ≤ 0.001), as well as among male and female children in the 6-10 years age group (P ≤ 0.05) but not in the other groups. Intraclass correlation coefficient values (0.78-0.95) show good agreement among the three optometrists for all parameters. The normal range of HVID, VVID, and PFH presented in the current study can help practitioners in the diagnosis of corneal disorders, serve as a basis for the design of contact lenses, and enable accurate intraocular lens power calculations for South Indian children.
期刊介绍:
The Journal of Medicine and Life publishes peer-reviewed articles from various fields of medicine and life sciences, including original research, systematic reviews, special reports, case presentations, major medical breakthroughs and letters to the editor. The Journal focuses on current matters that lie at the intersection of biomedical science and clinical practice and strives to present this information to inform health care delivery and improve patient outcomes. Papers addressing topics such as neuroprotection, neurorehabilitation, neuroplasticity, and neuroregeneration are particularly encouraged, as part of the Journal''s continuous interest in neuroscience research. The Editorial Board of the Journal of Medicine and Life is open to consider manuscripts from all levels of research and areas of biological sciences, including fundamental, experimental or clinical research and matters of public health. As part of our pledge to promote an educational and community-building environment, our issues feature sections designated to informing our readers regarding exciting international congresses, teaching courses and relevant institutional-level events.