收敛不足的特征。

K M Daum
{"title":"收敛不足的特征。","authors":"K M Daum","doi":"10.1097/00006324-198806000-00002","DOIUrl":null,"url":null,"abstract":"<p><p>Convergence insufficiency (CI) is a well-known syndrome of binocular visual dysfunction. In a review of 58 papers, considerable variation was noted in the criteria used to define the condition. Symptoms and decreased positive fusional vergences (both at the nearpoint) were the only criteria named in more than one-half of the studies. An extended nearpoint of convergence (NPC) and increased exophoria at near were criteria in about one-third of the papers. Examination of data in the reviewed papers shows that although considerable variability was noted, the distance exodeviation, distance negative vergences, visual acuity, refraction, and stereopsis were about the same as population norms. Positive vergences, negative vergence at near, and NPC were somewhat less than population norms. Vergences relative to Sheard's criterion, the near exophoria, accommodative amplitude, and the AC/A ratio were consistently below those derived from population norms. This considerable variation may largely be a result of different criteria used for diagnosis, subpopulations within the data, and other confounding factors.</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 6","pages":"426-38"},"PeriodicalIF":0.0000,"publicationDate":"1988-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00006324-198806000-00002","citationCount":"42","resultStr":"{\"title\":\"Characteristics of convergence insufficiency.\",\"authors\":\"K M Daum\",\"doi\":\"10.1097/00006324-198806000-00002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Convergence insufficiency (CI) is a well-known syndrome of binocular visual dysfunction. In a review of 58 papers, considerable variation was noted in the criteria used to define the condition. Symptoms and decreased positive fusional vergences (both at the nearpoint) were the only criteria named in more than one-half of the studies. An extended nearpoint of convergence (NPC) and increased exophoria at near were criteria in about one-third of the papers. Examination of data in the reviewed papers shows that although considerable variability was noted, the distance exodeviation, distance negative vergences, visual acuity, refraction, and stereopsis were about the same as population norms. Positive vergences, negative vergence at near, and NPC were somewhat less than population norms. Vergences relative to Sheard's criterion, the near exophoria, accommodative amplitude, and the AC/A ratio were consistently below those derived from population norms. This considerable variation may largely be a result of different criteria used for diagnosis, subpopulations within the data, and other confounding factors.</p>\",\"PeriodicalId\":7700,\"journal\":{\"name\":\"American journal of optometry and physiological optics\",\"volume\":\"65 6\",\"pages\":\"426-38\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1097/00006324-198806000-00002\",\"citationCount\":\"42\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of optometry and physiological optics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/00006324-198806000-00002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of optometry and physiological optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/00006324-198806000-00002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 42

摘要

会聚不全(CI)是一种众所周知的双目视觉功能障碍综合征。在对58篇论文的回顾中,在用于定义该病症的标准中发现了相当大的差异。在超过一半的研究中,症状和阳性融合点减少(都在近点)是唯一的标准。在大约三分之一的论文中,近收敛点(NPC)的扩展和近处外延的增加是标准。对所审查论文中的数据进行的检查表明,尽管注意到相当大的差异,但距离外偏差、距离负辐合、视力、屈光和立体视与总体标准大致相同。正辐合、近辐合和NPC均小于总体规范值。相对于Sheard标准的收敛度、近外极限、可调节振幅和AC/A比始终低于从人口标准得出的收敛度。这种相当大的差异可能主要是由于用于诊断的不同标准、数据中的亚群和其他混杂因素造成的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characteristics of convergence insufficiency.

Convergence insufficiency (CI) is a well-known syndrome of binocular visual dysfunction. In a review of 58 papers, considerable variation was noted in the criteria used to define the condition. Symptoms and decreased positive fusional vergences (both at the nearpoint) were the only criteria named in more than one-half of the studies. An extended nearpoint of convergence (NPC) and increased exophoria at near were criteria in about one-third of the papers. Examination of data in the reviewed papers shows that although considerable variability was noted, the distance exodeviation, distance negative vergences, visual acuity, refraction, and stereopsis were about the same as population norms. Positive vergences, negative vergence at near, and NPC were somewhat less than population norms. Vergences relative to Sheard's criterion, the near exophoria, accommodative amplitude, and the AC/A ratio were consistently below those derived from population norms. This considerable variation may largely be a result of different criteria used for diagnosis, subpopulations within the data, and other confounding factors.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信