Eman M Yahya, Ashraf S Alchalabi, Emad Farhan Alkhalidi
{"title":"不同导电根管冲洗对不同根尖定位仪准确性的影响:体外比较研究。","authors":"Eman M Yahya, Ashraf S Alchalabi, Emad Farhan Alkhalidi","doi":"10.4103/jispcd.jispcd_192_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>An accurate working length (WL) estimation is fundamental to a successful endodontic therapy. The objective of this comparative <i>in vitro</i> research was to investigate the performance of iPex II and the Root ZX Mini electronic apex locators (EALs) in measuring root canal WL with different irrigant solutions and their relation to the electrical conductivity of irrigation solutions.</p><p><strong>Materials and methods: </strong>Seventy sound permanent lower premolar teeth, each with a single root and developed apices, were used. Under an X15 stereomicroscope, the real working length was determined with the aid of a #10 file. After that, teeth were placed into an alginate model, and the iPex II and Root ZX Mini were used for the detection of electronic working length with various irrigants. Seventy teeth were randomly distributed into seven groups, 10 per each group (group I: dry canal; group II: distilled water; group III: ozonated water; group IV: 5% sodium hypochlorite (NaOCl); group V: 2% chlorhexidine, group VI: 17% ethylenediaminetetraacetic acid (EDTA) solution, and group VII: 17% EDTA gel). The difference in WL was calculated by deducting real working length from its electronic working length. The study also evaluates the electrical conductivity of the seven endodontic irrigant solutions. The two-way analysis of variance (ANOVA) test was used for statistical analysis.</p><p><strong>Results: </strong>Statistically, neither both types of EALs (<i>P</i> = 0.088) nor various irrigating solutions with varying electrical conductivities (<i>P</i> = 0.099) significantly affect the accuracy of EL estimation.</p><p><strong>Conclusions: </strong>There were no significant differences between the accuracy of the Root ZX Mini and the iPex II. The accuracy of both apex locators is unaffected in the presence of various irrigation solutions with varying electrical conductivities in this research.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11268530/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of Different Electroconductive Root Canal Irrigations on the Accuracy of Different Apex Locators: An <i>In Vitro</i> Comparative Study.\",\"authors\":\"Eman M Yahya, Ashraf S Alchalabi, Emad Farhan Alkhalidi\",\"doi\":\"10.4103/jispcd.jispcd_192_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>An accurate working length (WL) estimation is fundamental to a successful endodontic therapy. The objective of this comparative <i>in vitro</i> research was to investigate the performance of iPex II and the Root ZX Mini electronic apex locators (EALs) in measuring root canal WL with different irrigant solutions and their relation to the electrical conductivity of irrigation solutions.</p><p><strong>Materials and methods: </strong>Seventy sound permanent lower premolar teeth, each with a single root and developed apices, were used. Under an X15 stereomicroscope, the real working length was determined with the aid of a #10 file. After that, teeth were placed into an alginate model, and the iPex II and Root ZX Mini were used for the detection of electronic working length with various irrigants. Seventy teeth were randomly distributed into seven groups, 10 per each group (group I: dry canal; group II: distilled water; group III: ozonated water; group IV: 5% sodium hypochlorite (NaOCl); group V: 2% chlorhexidine, group VI: 17% ethylenediaminetetraacetic acid (EDTA) solution, and group VII: 17% EDTA gel). The difference in WL was calculated by deducting real working length from its electronic working length. The study also evaluates the electrical conductivity of the seven endodontic irrigant solutions. The two-way analysis of variance (ANOVA) test was used for statistical analysis.</p><p><strong>Results: </strong>Statistically, neither both types of EALs (<i>P</i> = 0.088) nor various irrigating solutions with varying electrical conductivities (<i>P</i> = 0.099) significantly affect the accuracy of EL estimation.</p><p><strong>Conclusions: </strong>There were no significant differences between the accuracy of the Root ZX Mini and the iPex II. The accuracy of both apex locators is unaffected in the presence of various irrigation solutions with varying electrical conductivities in this research.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11268530/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jispcd.jispcd_192_23\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jispcd.jispcd_192_23","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
摘要
目的:准确估计工作长度(WL)是成功进行根管治疗的基础。这项体外比较研究的目的是调查 iPex II 和 Root ZX Mini 电子根尖定位器 (EAL) 在使用不同灌洗液测量根管工作长度时的性能,以及它们与灌洗液导电性的关系:使用 70 颗健全的下前臼齿恒牙,每颗恒牙均为单根,根尖发达。在 X15 立体显微镜下,用 10 号锉刀确定实际工作长度。然后,将牙齿放入藻酸盐模型中,使用 iPex II 和 Root ZX Mini 用不同的冲洗剂检测电子工作长度。70 颗牙齿被随机分为七组,每组 10 颗(第一组:干管;第二组:蒸馏水;第三组:臭氧水;第四组:5% 次氯酸钠(NaOCl);第五组:2% 洗必泰;第六组:17% 乙二胺四乙酸(EDTA)溶液;第七组:17% EDTA 凝胶)。实际工作长度减去电子工作长度后计算出 WL 差值。研究还评估了七种牙髓冲洗液的导电性。统计分析采用了双因素方差分析(ANOVA)检验:从统计学角度来看,两种类型的 EAL(P = 0.088)和不同导电率的各种冲洗液(P = 0.099)都不会显著影响 EL 估算的准确性:结论:Root ZX Mini 和 iPex II 的准确性没有明显差异。在这项研究中,两种牙尖定位仪的准确性在不同导电率的灌溉溶液中都不受影响。
Effect of Different Electroconductive Root Canal Irrigations on the Accuracy of Different Apex Locators: An In Vitro Comparative Study.
Aim: An accurate working length (WL) estimation is fundamental to a successful endodontic therapy. The objective of this comparative in vitro research was to investigate the performance of iPex II and the Root ZX Mini electronic apex locators (EALs) in measuring root canal WL with different irrigant solutions and their relation to the electrical conductivity of irrigation solutions.
Materials and methods: Seventy sound permanent lower premolar teeth, each with a single root and developed apices, were used. Under an X15 stereomicroscope, the real working length was determined with the aid of a #10 file. After that, teeth were placed into an alginate model, and the iPex II and Root ZX Mini were used for the detection of electronic working length with various irrigants. Seventy teeth were randomly distributed into seven groups, 10 per each group (group I: dry canal; group II: distilled water; group III: ozonated water; group IV: 5% sodium hypochlorite (NaOCl); group V: 2% chlorhexidine, group VI: 17% ethylenediaminetetraacetic acid (EDTA) solution, and group VII: 17% EDTA gel). The difference in WL was calculated by deducting real working length from its electronic working length. The study also evaluates the electrical conductivity of the seven endodontic irrigant solutions. The two-way analysis of variance (ANOVA) test was used for statistical analysis.
Results: Statistically, neither both types of EALs (P = 0.088) nor various irrigating solutions with varying electrical conductivities (P = 0.099) significantly affect the accuracy of EL estimation.
Conclusions: There were no significant differences between the accuracy of the Root ZX Mini and the iPex II. The accuracy of both apex locators is unaffected in the presence of various irrigation solutions with varying electrical conductivities in this research.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.