Tinne Gils, Jerry Hella, Bart K M Jacobs, Bianca Sossen, Madalo Mukoka, Monde Muyoyeta, Elizabeth Nakabugo, Hung Van Nguyen, Sasiwimol Ubolyam, Aurélien Macé, Marcia Vermeulen, Sarah Nyangu, Nsala Sanjase, Mohamed Sasamalo, Huong Thi Dinh, The Anh Ngo, Weerawat Manosuthi, Supunnee Jirajariyavej, Claudia M Denkinger, Nhung Viet Nguyen, Anchalee Avihingsanon, Lydia Nakiyingi, Rita Székely, Andrew D Kerkhoff, Peter MacPherson, Graeme Meintjes, Klaus Reither, Morten Ruhwald
{"title":"对七个国家的 VISITECT CD4 高危疾病床旁检测诊断准确性的前瞻性评估。","authors":"Tinne Gils, Jerry Hella, Bart K M Jacobs, Bianca Sossen, Madalo Mukoka, Monde Muyoyeta, Elizabeth Nakabugo, Hung Van Nguyen, Sasiwimol Ubolyam, Aurélien Macé, Marcia Vermeulen, Sarah Nyangu, Nsala Sanjase, Mohamed Sasamalo, Huong Thi Dinh, The Anh Ngo, Weerawat Manosuthi, Supunnee Jirajariyavej, Claudia M Denkinger, Nhung Viet Nguyen, Anchalee Avihingsanon, Lydia Nakiyingi, Rita Székely, Andrew D Kerkhoff, Peter MacPherson, Graeme Meintjes, Klaus Reither, Morten Ruhwald","doi":"10.1093/infdis/jiae374","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>CD4 measurement is pivotal in the management of advanced human immunodeficiency virus (HIV) disease. VISITECT CD4 Advanced Disease (VISITECT; AccuBio, Ltd) is an instrument-free, point-of-care, semiquantitative test allowing visual identification of CD4 ≤ 200 cells/µL or >200 cells/ µL from finger-prick or venous blood.</p><p><strong>Methods: </strong>As part of a diagnostic accuracy study of FUJIFILM SILVAMP TB LAM, people with HIV ≥18 years old were prospectively recruited in 7 countries from outpatient departments if a tuberculosis symptom was present, and from inpatient departments. Participants provided venous blood for CD4 measurement using flow cytometry (reference standard) and finger-prick blood for VISITECT (index text), performed at point-of-care. Sensitivity, specificity, and positive and negative predictive values of VISITECT to determine CD4 ≤ 200 cells/ µL were evaluated.</p><p><strong>Results: </strong>Among 1604 participants, the median flow cytometry CD4 was 367 cells/µL (interquartile range, 128-626 cells/µL) and 521 (32.5%) had CD4 ≤ 200 cells/µL. VISITECT sensitivity was 92.7% (483/521; 95% confidence interval [CI], 90.1%-94.7%) and specificity was 61.4% (665/1083; 95% CI, 58.4%-64.3%). For participants with CD4 0-100, 101-200, 201-300, 301-500, and >500 cells/µL, VISITECT misclassified 4.5% (95% CI, 2.5%-7.2%), 12.5 (95% CI, 8.0%-18.2%), 74.1% (95% CI, 67.0%-80.5%), 48.0% (95% CI, 42.5%-53.6%), and 22.6% (95% CI, 19.3%-26.3%), respectively.</p><p><strong>Conclusions: </strong>VISITECT's sensitivity, but not specificity, met the World Health Organization's minimal sensitivity and specificity threshold of 80% for point-of-care CD4 tests. VISITECT's quality needs to be assessed and its accuracy optimized. VISITECT's utility as CD4 triage test should be investigated. Clinical Trials Registration. NCT04089423.</p>","PeriodicalId":50179,"journal":{"name":"Journal of Infectious Diseases","volume":" ","pages":"e82-e90"},"PeriodicalIF":5.0000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11793025/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Prospective Evaluation of the Diagnostic Accuracy of the Point-of-Care VISITECT CD4 Advanced Disease Test in 7 Countries.\",\"authors\":\"Tinne Gils, Jerry Hella, Bart K M Jacobs, Bianca Sossen, Madalo Mukoka, Monde Muyoyeta, Elizabeth Nakabugo, Hung Van Nguyen, Sasiwimol Ubolyam, Aurélien Macé, Marcia Vermeulen, Sarah Nyangu, Nsala Sanjase, Mohamed Sasamalo, Huong Thi Dinh, The Anh Ngo, Weerawat Manosuthi, Supunnee Jirajariyavej, Claudia M Denkinger, Nhung Viet Nguyen, Anchalee Avihingsanon, Lydia Nakiyingi, Rita Székely, Andrew D Kerkhoff, Peter MacPherson, Graeme Meintjes, Klaus Reither, Morten Ruhwald\",\"doi\":\"10.1093/infdis/jiae374\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>CD4 measurement is pivotal in the management of advanced human immunodeficiency virus (HIV) disease. VISITECT CD4 Advanced Disease (VISITECT; AccuBio, Ltd) is an instrument-free, point-of-care, semiquantitative test allowing visual identification of CD4 ≤ 200 cells/µL or >200 cells/ µL from finger-prick or venous blood.</p><p><strong>Methods: </strong>As part of a diagnostic accuracy study of FUJIFILM SILVAMP TB LAM, people with HIV ≥18 years old were prospectively recruited in 7 countries from outpatient departments if a tuberculosis symptom was present, and from inpatient departments. Participants provided venous blood for CD4 measurement using flow cytometry (reference standard) and finger-prick blood for VISITECT (index text), performed at point-of-care. Sensitivity, specificity, and positive and negative predictive values of VISITECT to determine CD4 ≤ 200 cells/ µL were evaluated.</p><p><strong>Results: </strong>Among 1604 participants, the median flow cytometry CD4 was 367 cells/µL (interquartile range, 128-626 cells/µL) and 521 (32.5%) had CD4 ≤ 200 cells/µL. VISITECT sensitivity was 92.7% (483/521; 95% confidence interval [CI], 90.1%-94.7%) and specificity was 61.4% (665/1083; 95% CI, 58.4%-64.3%). For participants with CD4 0-100, 101-200, 201-300, 301-500, and >500 cells/µL, VISITECT misclassified 4.5% (95% CI, 2.5%-7.2%), 12.5 (95% CI, 8.0%-18.2%), 74.1% (95% CI, 67.0%-80.5%), 48.0% (95% CI, 42.5%-53.6%), and 22.6% (95% CI, 19.3%-26.3%), respectively.</p><p><strong>Conclusions: </strong>VISITECT's sensitivity, but not specificity, met the World Health Organization's minimal sensitivity and specificity threshold of 80% for point-of-care CD4 tests. VISITECT's quality needs to be assessed and its accuracy optimized. VISITECT's utility as CD4 triage test should be investigated. Clinical Trials Registration. NCT04089423.</p>\",\"PeriodicalId\":50179,\"journal\":{\"name\":\"Journal of Infectious Diseases\",\"volume\":\" \",\"pages\":\"e82-e90\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2025-02-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11793025/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Infectious Diseases\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/infdis/jiae374\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"IMMUNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Infectious Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/infdis/jiae374","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
A Prospective Evaluation of the Diagnostic Accuracy of the Point-of-Care VISITECT CD4 Advanced Disease Test in 7 Countries.
Background: CD4 measurement is pivotal in the management of advanced human immunodeficiency virus (HIV) disease. VISITECT CD4 Advanced Disease (VISITECT; AccuBio, Ltd) is an instrument-free, point-of-care, semiquantitative test allowing visual identification of CD4 ≤ 200 cells/µL or >200 cells/ µL from finger-prick or venous blood.
Methods: As part of a diagnostic accuracy study of FUJIFILM SILVAMP TB LAM, people with HIV ≥18 years old were prospectively recruited in 7 countries from outpatient departments if a tuberculosis symptom was present, and from inpatient departments. Participants provided venous blood for CD4 measurement using flow cytometry (reference standard) and finger-prick blood for VISITECT (index text), performed at point-of-care. Sensitivity, specificity, and positive and negative predictive values of VISITECT to determine CD4 ≤ 200 cells/ µL were evaluated.
Results: Among 1604 participants, the median flow cytometry CD4 was 367 cells/µL (interquartile range, 128-626 cells/µL) and 521 (32.5%) had CD4 ≤ 200 cells/µL. VISITECT sensitivity was 92.7% (483/521; 95% confidence interval [CI], 90.1%-94.7%) and specificity was 61.4% (665/1083; 95% CI, 58.4%-64.3%). For participants with CD4 0-100, 101-200, 201-300, 301-500, and >500 cells/µL, VISITECT misclassified 4.5% (95% CI, 2.5%-7.2%), 12.5 (95% CI, 8.0%-18.2%), 74.1% (95% CI, 67.0%-80.5%), 48.0% (95% CI, 42.5%-53.6%), and 22.6% (95% CI, 19.3%-26.3%), respectively.
Conclusions: VISITECT's sensitivity, but not specificity, met the World Health Organization's minimal sensitivity and specificity threshold of 80% for point-of-care CD4 tests. VISITECT's quality needs to be assessed and its accuracy optimized. VISITECT's utility as CD4 triage test should be investigated. Clinical Trials Registration. NCT04089423.
期刊介绍:
Published continuously since 1904, The Journal of Infectious Diseases (JID) is the premier global journal for original research on infectious diseases. The editors welcome Major Articles and Brief Reports describing research results on microbiology, immunology, epidemiology, and related disciplines, on the pathogenesis, diagnosis, and treatment of infectious diseases; on the microbes that cause them; and on disorders of host immune responses. JID is an official publication of the Infectious Diseases Society of America.