评估健康成年人的 SpotChecks 对比敏感度测试。

IF 2.8 3区 医学 Q1 OPHTHALMOLOGY
Ophthalmic and Physiological Optics Pub Date : 2024-09-01 Epub Date: 2024-06-21 DOI:10.1111/opo.13349
Lien T Vu, Kelly M Tran, Yabo Niu, Han Cheng
{"title":"评估健康成年人的 SpotChecks 对比敏感度测试。","authors":"Lien T Vu, Kelly M Tran, Yabo Niu, Han Cheng","doi":"10.1111/opo.13349","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>SpotChecks is a new contrast sensitivity (CS) test designed for self-monitoring of vision. This study assessed the test-retest repeatability of take-home SpotChecks, in-office SpotChecks and near Pelli-Robson charts in healthy adults.</p><p><strong>Methods: </strong>One eye of 61 healthy adults with near visual acuity (VA) of 6/9 or better (age range 22-84, mean 49 [18] years) was tested during two office visits (mean 10 [8] days apart). Each visit included high-contrast VA, then 12 randomly ordered CS tests (6 different SpotChecks and 6 different Pelli-Robson) under the same lighting (luminance 110 cd/m<sup>2</sup>), all at near in the same eye with habitual correction. The same eye was self-tested with take-home SpotChecks once a day on 6 days between the office visits. SpotChecks was scored by the logCS at the highest line with ≥2 errors. Pelli-Robson was scored by [0.05 × number of letters read correctly - 0.15]. Repeatability of logCS was defined as 1.96 <math> <semantics> <mrow><msqrt><mn>2</mn></msqrt> </mrow> </semantics> </math> S<sub>w</sub>, S<sub>w</sub> representing within-subject standard deviation. Comparison for repeatability was performed with Bootstrap hypothesis test.</p><p><strong>Results: </strong>SpotChecks and Pelli-Robson showed similar intra-session or inter-visit repeatability (p = 0.14-0.81). Inter-day repeatability for take-home SpotChecks was 0.18 logCS, the same as that from the first measurements of two office visits with SpotChecks or Pelli-Robson. Inter-visit repeatability improved to 0.15 by using the average of two repeated measurements for SpotChecks (p = 0.02) or three repeated measurements for Pelli-Robson (p = 0.04). Age showed a small effect on logCS (-0.015/decade, p = 0.02) for both SpotChecks and Pelli-Robson. Mean logCS was 0.05 lower in those ≥50 years (SpotChecks 1.84 [0.10] and Pelli-Robson 1.77 [0.10]) compared with those <50 years of age (SpotChecks 1.89 [0.07] and Pelli-Robson 1.83 [0.07]).</p><p><strong>Conclusions: </strong>SpotChecks showed good repeatability with take-home and in-office testing in healthy adults, making it a promising tool for monitoring disease progression at home.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the SpotChecks contrast sensitivity test in healthy adults.\",\"authors\":\"Lien T Vu, Kelly M Tran, Yabo Niu, Han Cheng\",\"doi\":\"10.1111/opo.13349\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>SpotChecks is a new contrast sensitivity (CS) test designed for self-monitoring of vision. This study assessed the test-retest repeatability of take-home SpotChecks, in-office SpotChecks and near Pelli-Robson charts in healthy adults.</p><p><strong>Methods: </strong>One eye of 61 healthy adults with near visual acuity (VA) of 6/9 or better (age range 22-84, mean 49 [18] years) was tested during two office visits (mean 10 [8] days apart). Each visit included high-contrast VA, then 12 randomly ordered CS tests (6 different SpotChecks and 6 different Pelli-Robson) under the same lighting (luminance 110 cd/m<sup>2</sup>), all at near in the same eye with habitual correction. The same eye was self-tested with take-home SpotChecks once a day on 6 days between the office visits. SpotChecks was scored by the logCS at the highest line with ≥2 errors. Pelli-Robson was scored by [0.05 × number of letters read correctly - 0.15]. Repeatability of logCS was defined as 1.96 <math> <semantics> <mrow><msqrt><mn>2</mn></msqrt> </mrow> </semantics> </math> S<sub>w</sub>, S<sub>w</sub> representing within-subject standard deviation. Comparison for repeatability was performed with Bootstrap hypothesis test.</p><p><strong>Results: </strong>SpotChecks and Pelli-Robson showed similar intra-session or inter-visit repeatability (p = 0.14-0.81). Inter-day repeatability for take-home SpotChecks was 0.18 logCS, the same as that from the first measurements of two office visits with SpotChecks or Pelli-Robson. Inter-visit repeatability improved to 0.15 by using the average of two repeated measurements for SpotChecks (p = 0.02) or three repeated measurements for Pelli-Robson (p = 0.04). Age showed a small effect on logCS (-0.015/decade, p = 0.02) for both SpotChecks and Pelli-Robson. Mean logCS was 0.05 lower in those ≥50 years (SpotChecks 1.84 [0.10] and Pelli-Robson 1.77 [0.10]) compared with those <50 years of age (SpotChecks 1.89 [0.07] and Pelli-Robson 1.83 [0.07]).</p><p><strong>Conclusions: </strong>SpotChecks showed good repeatability with take-home and in-office testing in healthy adults, making it a promising tool for monitoring disease progression at home.</p>\",\"PeriodicalId\":19522,\"journal\":{\"name\":\"Ophthalmic and Physiological Optics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmic and Physiological Optics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/opo.13349\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13349","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/21 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:SpotChecks 是一种新的对比敏感度 (CS) 测试,设计用于自我监测视力。本研究评估了健康成年人带回家的 SpotChecks、诊室 SpotChecks 和近距离佩利-罗布森视力表的测试重复性:方法:61 名近距离视力 (VA) 为 6/9 或更佳的健康成年人(年龄在 22-84 岁之间,平均 49 [18] 岁)的一只眼睛在两次就诊(平均相隔 10 [8] 天)期间接受了测试。每次就诊包括高对比度 VA,然后在相同的照明(亮度为 110 cd/m2)条件下进行 12 次随机排序的 CS 测试(6 次不同的 SpotChecks 和 6 次不同的 Pelli-Robson 测试),所有测试均在习惯性矫正的同一只眼睛的近距离进行。在两次就诊之间的 6 天内,同一只眼睛每天进行一次带回家的 SpotChecks 自我测试。SpotChecks 以误差≥2 的最高线上的对数CS评分。佩里-罗布森评分标准为[0.05×正确读取的字母数-0.15]。logCS 的重复性定义为 1.96 2 $$ \sqrt{2} $$ Sw,Sw 代表受试内标准偏差。重复性比较采用 Bootstrap 假设检验:SpotChecks 和 Pelli-Robson 显示出相似的时段内或访问间重复性(p = 0.14-0.81)。带回家的 SpotChecks 的日间重复性为 0.18 logCS,与使用 SpotChecks 或 Pelli-Robson 进行两次诊疗的首次测量结果相同。使用 SpotChecks 两次重复测量的平均值(p = 0.02)或 Pelli-Robson 三次重复测量的平均值(p = 0.04),就诊间重复性提高到 0.15。年龄对 SpotChecks 和 Pelli-Robson 的对数CS影响较小(-0.015/十年,p = 0.02)。与得出结论者相比,年龄≥50 岁者的平均对数值低 0.05(SpotChecks 为 1.84 [0.10],Pelli-Robson 为 1.77 [0.10]):SpotChecks 在健康成年人中显示出良好的居家和诊室检测重复性,使其成为居家监测疾病进展的理想工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the SpotChecks contrast sensitivity test in healthy adults.

Purpose: SpotChecks is a new contrast sensitivity (CS) test designed for self-monitoring of vision. This study assessed the test-retest repeatability of take-home SpotChecks, in-office SpotChecks and near Pelli-Robson charts in healthy adults.

Methods: One eye of 61 healthy adults with near visual acuity (VA) of 6/9 or better (age range 22-84, mean 49 [18] years) was tested during two office visits (mean 10 [8] days apart). Each visit included high-contrast VA, then 12 randomly ordered CS tests (6 different SpotChecks and 6 different Pelli-Robson) under the same lighting (luminance 110 cd/m2), all at near in the same eye with habitual correction. The same eye was self-tested with take-home SpotChecks once a day on 6 days between the office visits. SpotChecks was scored by the logCS at the highest line with ≥2 errors. Pelli-Robson was scored by [0.05 × number of letters read correctly - 0.15]. Repeatability of logCS was defined as 1.96 2 Sw, Sw representing within-subject standard deviation. Comparison for repeatability was performed with Bootstrap hypothesis test.

Results: SpotChecks and Pelli-Robson showed similar intra-session or inter-visit repeatability (p = 0.14-0.81). Inter-day repeatability for take-home SpotChecks was 0.18 logCS, the same as that from the first measurements of two office visits with SpotChecks or Pelli-Robson. Inter-visit repeatability improved to 0.15 by using the average of two repeated measurements for SpotChecks (p = 0.02) or three repeated measurements for Pelli-Robson (p = 0.04). Age showed a small effect on logCS (-0.015/decade, p = 0.02) for both SpotChecks and Pelli-Robson. Mean logCS was 0.05 lower in those ≥50 years (SpotChecks 1.84 [0.10] and Pelli-Robson 1.77 [0.10]) compared with those <50 years of age (SpotChecks 1.89 [0.07] and Pelli-Robson 1.83 [0.07]).

Conclusions: SpotChecks showed good repeatability with take-home and in-office testing in healthy adults, making it a promising tool for monitoring disease progression at home.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
13.80%
发文量
135
审稿时长
6-12 weeks
期刊介绍: Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry. OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信