通过临床高能光子束量化静态随机存取存储器中由中子诱发的单次事件中断

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Lukas Gabrisch;Matteo Cecchetto;Björn Delfs;Hui Khee Looe;Jan Budroweit;Rubén García Alía;Björn Poppe;Vanessa Wyrwoll
{"title":"通过临床高能光子束量化静态随机存取存储器中由中子诱发的单次事件中断","authors":"Lukas Gabrisch;Matteo Cecchetto;Björn Delfs;Hui Khee Looe;Jan Budroweit;Rubén García Alía;Björn Poppe;Vanessa Wyrwoll","doi":"10.1109/TNS.2024.3427773","DOIUrl":null,"url":null,"abstract":"The possibility of using calibrated static random-access memory (SRAM) memory for the quantification of neutron fluence in a radiotherapy facility for cancer treatment utilizing a high-energy 15-MV photon beam (Bremsstrahlung) from an electron linear accelerator has been exploited in this work. This has been performed by varying the field size of the photon beam and the positioning of the SRAM memory at three different positions in relation to the isocenter of the beam. The measurements demonstrated that neutrons originating from interactions between the high-energy photons and accelerator parts with high-Z materials are able to induce single-event upsets (SEUs) in the SRAM memory, where the measured SEUs depend on the measurement location. Monte Carlo (MC) simulations have been performed to retrieve the neutron fluence under each investigated measurement condition. Using the simulated neutron fluence differential in energy and the interactions cross sections determined previously, the expected SEUs were computed. The comparison between measured and simulated SEUs normalized to the linear accelerators (linac) output shows acceptable agreement within the experimental uncertainties. As exposure to secondary neutrons poses a risk to all patients, especially the ones with pacemakers or other electronical aids, the feasibility of establishing the neutron fluence through SEU quantification in an SRAM device provides new opportunities to estimate the associated risk in a clinical environment. Further work can be performed to investigate the correlation between the high-Z linac components and the neutron fluence during patient irradiation to better comprehend the variation between different linac types and manufacturers.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10597644","citationCount":"0","resultStr":"{\"title\":\"Quantification of Neutron-Induced Single-Event Upsets in a Static Random-Access Memory by Clinical High-Energy Photon Beam\",\"authors\":\"Lukas Gabrisch;Matteo Cecchetto;Björn Delfs;Hui Khee Looe;Jan Budroweit;Rubén García Alía;Björn Poppe;Vanessa Wyrwoll\",\"doi\":\"10.1109/TNS.2024.3427773\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The possibility of using calibrated static random-access memory (SRAM) memory for the quantification of neutron fluence in a radiotherapy facility for cancer treatment utilizing a high-energy 15-MV photon beam (Bremsstrahlung) from an electron linear accelerator has been exploited in this work. This has been performed by varying the field size of the photon beam and the positioning of the SRAM memory at three different positions in relation to the isocenter of the beam. The measurements demonstrated that neutrons originating from interactions between the high-energy photons and accelerator parts with high-Z materials are able to induce single-event upsets (SEUs) in the SRAM memory, where the measured SEUs depend on the measurement location. Monte Carlo (MC) simulations have been performed to retrieve the neutron fluence under each investigated measurement condition. Using the simulated neutron fluence differential in energy and the interactions cross sections determined previously, the expected SEUs were computed. The comparison between measured and simulated SEUs normalized to the linear accelerators (linac) output shows acceptable agreement within the experimental uncertainties. As exposure to secondary neutrons poses a risk to all patients, especially the ones with pacemakers or other electronical aids, the feasibility of establishing the neutron fluence through SEU quantification in an SRAM device provides new opportunities to estimate the associated risk in a clinical environment. Further work can be performed to investigate the correlation between the high-Z linac components and the neutron fluence during patient irradiation to better comprehend the variation between different linac types and manufacturers.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10597644\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10597644/\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10597644/","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

本研究利用电子直线加速器发出的 15-MV 高能光子束(轫致辐射),在癌症放疗设备中使用校准静态随机存取存储器(SRAM)对中子通量进行量化。测量方法是改变光子束的磁场大小以及 SRAM 存储器相对于光子束等中心的三个不同位置。测量结果表明,来自高能光子和加速器部件与高 Z 材料之间相互作用的中子能够在 SRAM 存储器中诱发单次事件中断(SEU),测量到的 SEU 取决于测量位置。我们进行了蒙特卡罗(MC)模拟,以检索每个调查测量条件下的中子通量。利用模拟的中子能量通量差和先前确定的相互作用截面,计算出预期的 SEU。将测量和模拟的 SEU 与线性加速器(linac)输出归一化后进行比较,结果显示在实验不确定性范围内两者的一致性是可以接受的。由于暴露于二次中子对所有病人,特别是装有心脏起搏器或其他电子辅助设备的病人都构成风险,因此在 SRAM 设备中通过 SEU 量化确定中子通量的可行性为估计临床环境中的相关风险提供了新的机会。还可以开展进一步的工作,研究病人辐照期间高 Z 直列加速器组件与中子通量之间的相关性,以便更好地理解不同直列加速器类型和制造商之间的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Quantification of Neutron-Induced Single-Event Upsets in a Static Random-Access Memory by Clinical High-Energy Photon Beam
The possibility of using calibrated static random-access memory (SRAM) memory for the quantification of neutron fluence in a radiotherapy facility for cancer treatment utilizing a high-energy 15-MV photon beam (Bremsstrahlung) from an electron linear accelerator has been exploited in this work. This has been performed by varying the field size of the photon beam and the positioning of the SRAM memory at three different positions in relation to the isocenter of the beam. The measurements demonstrated that neutrons originating from interactions between the high-energy photons and accelerator parts with high-Z materials are able to induce single-event upsets (SEUs) in the SRAM memory, where the measured SEUs depend on the measurement location. Monte Carlo (MC) simulations have been performed to retrieve the neutron fluence under each investigated measurement condition. Using the simulated neutron fluence differential in energy and the interactions cross sections determined previously, the expected SEUs were computed. The comparison between measured and simulated SEUs normalized to the linear accelerators (linac) output shows acceptable agreement within the experimental uncertainties. As exposure to secondary neutrons poses a risk to all patients, especially the ones with pacemakers or other electronical aids, the feasibility of establishing the neutron fluence through SEU quantification in an SRAM device provides new opportunities to estimate the associated risk in a clinical environment. Further work can be performed to investigate the correlation between the high-Z linac components and the neutron fluence during patient irradiation to better comprehend the variation between different linac types and manufacturers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信