日本可穿戴式心律转复除颤器的使用现状

IF 2.2 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Reina Tonegawa-Kuji MD, PhD, Taku Nishida MD, PhD, Yoko Sumita, Yoshihiro Miyamoto MD, PhD, Koshiro Kanaoka MD, PhD
{"title":"日本可穿戴式心律转复除颤器的使用现状","authors":"Reina Tonegawa-Kuji MD, PhD,&nbsp;Taku Nishida MD, PhD,&nbsp;Yoko Sumita,&nbsp;Yoshihiro Miyamoto MD, PhD,&nbsp;Koshiro Kanaoka MD, PhD","doi":"10.1002/joa3.13113","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>The current status of wearable cardiovascular defibrillators (WCD) use in Japan is unclear.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Using a nationwide claims database of Japan, we assessed characteristics of patients using WCD and factors influencing subsequent implantable cardioverter-defibrillator (ICD) implantation.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>In 1049 cases, those with prior cardiopulmonary arrest (CPA) or ventricular arrhythmia, cardiomyopathy, or device-related issues were more likely to require permanent ICDs, whereas females were less likely.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Prior CPA or fatal arrhythmia, underlying cardiomyopathy, or device-related issues were associated with future permanent ICD implantation. These findings offer insights into the current status of WCD use in Japan.</p>\n </section>\n </div>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"40 4","pages":"998-1000"},"PeriodicalIF":2.2000,"publicationDate":"2024-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.13113","citationCount":"0","resultStr":"{\"title\":\"Current status of wearable cardioverter-defibrillator use in Japan\",\"authors\":\"Reina Tonegawa-Kuji MD, PhD,&nbsp;Taku Nishida MD, PhD,&nbsp;Yoko Sumita,&nbsp;Yoshihiro Miyamoto MD, PhD,&nbsp;Koshiro Kanaoka MD, PhD\",\"doi\":\"10.1002/joa3.13113\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>The current status of wearable cardiovascular defibrillators (WCD) use in Japan is unclear.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Using a nationwide claims database of Japan, we assessed characteristics of patients using WCD and factors influencing subsequent implantable cardioverter-defibrillator (ICD) implantation.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>In 1049 cases, those with prior cardiopulmonary arrest (CPA) or ventricular arrhythmia, cardiomyopathy, or device-related issues were more likely to require permanent ICDs, whereas females were less likely.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>Prior CPA or fatal arrhythmia, underlying cardiomyopathy, or device-related issues were associated with future permanent ICD implantation. These findings offer insights into the current status of WCD use in Japan.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15174,\"journal\":{\"name\":\"Journal of Arrhythmia\",\"volume\":\"40 4\",\"pages\":\"998-1000\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-07-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.13113\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Arrhythmia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/joa3.13113\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.13113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

我们利用日本全国范围的理赔数据库,评估了使用可穿戴式心血管除颤器(WCD)患者的特征以及影响后续植入式心律转复除颤器(ICD)的因素。在 1049 个病例中,有心肺骤停(CPA)或室性心律失常、心肌病或设备相关问题的患者更有可能需要永久性 ICD,而女性患者的可能性较低。这些研究结果为了解日本 WCD 的使用现状提供了参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Current status of wearable cardioverter-defibrillator use in Japan

Current status of wearable cardioverter-defibrillator use in Japan

Background

The current status of wearable cardiovascular defibrillators (WCD) use in Japan is unclear.

Methods

Using a nationwide claims database of Japan, we assessed characteristics of patients using WCD and factors influencing subsequent implantable cardioverter-defibrillator (ICD) implantation.

Results

In 1049 cases, those with prior cardiopulmonary arrest (CPA) or ventricular arrhythmia, cardiomyopathy, or device-related issues were more likely to require permanent ICDs, whereas females were less likely.

Conclusions

Prior CPA or fatal arrhythmia, underlying cardiomyopathy, or device-related issues were associated with future permanent ICD implantation. These findings offer insights into the current status of WCD use in Japan.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信