Swe Zin Linn Htet, Takuya Kondo, Takuma Miyake, Tatsuya Sakoda, Takeshi Nishimura
求助PDF
{"title":"环氧树脂破裂前的局部放电行为","authors":"Swe Zin Linn Htet, Takuya Kondo, Takuma Miyake, Tatsuya Sakoda, Takeshi Nishimura","doi":"10.1002/tee.24160","DOIUrl":null,"url":null,"abstract":"<p>To evaluate the deterioration degree of insulation material by monitoring partial discharges (PDs), it is necessary to fully understand the PD behavior prior to breakdown. We performed measurements of temporal variations in the number and magnitude of PDs in a void of epoxy resin. It was found that the number of PDs with larger magnitude is less before breakdown and that there is a decreased tendency of the number and magnitude of PDs with the elapsed time. The tendency is remarkable as the applied electric field is small. Additionally, the time to breakdown becomes short when the scattering of the number of PDs per unit time decreases. © 2024 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.</p>","PeriodicalId":13435,"journal":{"name":"IEEJ Transactions on Electrical and Electronic Engineering","volume":"19 12","pages":"1927-1935"},"PeriodicalIF":1.0000,"publicationDate":"2024-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Partial Discharge Behavior Prior to Breakdown in Epoxy Resin\",\"authors\":\"Swe Zin Linn Htet, Takuya Kondo, Takuma Miyake, Tatsuya Sakoda, Takeshi Nishimura\",\"doi\":\"10.1002/tee.24160\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>To evaluate the deterioration degree of insulation material by monitoring partial discharges (PDs), it is necessary to fully understand the PD behavior prior to breakdown. We performed measurements of temporal variations in the number and magnitude of PDs in a void of epoxy resin. It was found that the number of PDs with larger magnitude is less before breakdown and that there is a decreased tendency of the number and magnitude of PDs with the elapsed time. The tendency is remarkable as the applied electric field is small. Additionally, the time to breakdown becomes short when the scattering of the number of PDs per unit time decreases. © 2024 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.</p>\",\"PeriodicalId\":13435,\"journal\":{\"name\":\"IEEJ Transactions on Electrical and Electronic Engineering\",\"volume\":\"19 12\",\"pages\":\"1927-1935\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-07-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEJ Transactions on Electrical and Electronic Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/tee.24160\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEJ Transactions on Electrical and Electronic Engineering","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/tee.24160","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
引用
批量引用