Lei Zhao, Bing-Hua Chen, Hui Tang, Yong-Yi Wang, Zi-Yi Gu, Dong-Aolei An, Lian-Ming Wu, Song Xue
{"title":"心脏 T2*BOLD 与定量血流比率 (QFR) 在诊断多血管冠状动脉疾病患者冠状动脉狭窄中的关联。","authors":"Lei Zhao, Bing-Hua Chen, Hui Tang, Yong-Yi Wang, Zi-Yi Gu, Dong-Aolei An, Lian-Ming Wu, Song Xue","doi":"10.1007/s11547-024-01847-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>T2*BOLD is based on myocardial deoxyhemoglobin content to reflect the state of myocardial oxygenation. Quantitative flow ratio is a tool for assessing coronary blood flow based on invasive coronary angiography.</p><p><strong>Purpose: </strong>This study aimed to evaluate the correlation between T2*BOLD and QFR in the diagnosis of stenotic coronary arteries in patients with multi-vessel coronary artery disease.</p><p><strong>Methods: </strong>Fifty patients with MVCAD with at least 1 significant coronary artery stenosis (diameter stenosis > 50%) and 21 healthy control subjects underwent coronary angiography combined with QFR measurements and cardiovascular magnetic resonance (CMR). QFR ≤ 0.80 was considered to indicate the presence of hemodynamic obstruction.</p><p><strong>Results: </strong>Totally 60 (54%) obstructive vessels had hemodynamic change. Between stenotic coronary arteries (QFR ≤ 0.8) and normal vessels, T2*BOLD showed AUCs of 0.97, 0.69, and 0.91 for left anterior descending (LAD), left circumflex (LCX) and right coronary (RCA) arteries and PI displayed AUCs of 0.89, 0.77 and 0.90 (all p > 0.05, except for LAD). The AUCs of T2*BOLD between stenotic coronary arteries (QFR > 0.8) and normal vessels were 0.86, 0.72, and 0.85 for LAD, LCX and RCA; while, PI showed AUCs of 0.93, 0.86, and 0.88, respectively (p > 0.05). Moreover, T2*BOLD displayed AUCs of 0.96, 0.74, and 0.91 for coronary arteries as before between coronary arteries with stenosis (QFR ≤ 0.8 and > 0.8), but the mean PI of LAD, LCX and RCA showed no significant differences between them.</p><p><strong>Conclusion: </strong>T2* BOLD and QFR have good correlation in diagnosing stenotic coronary arteries with hemodynamic changes in patients with stable multi-vessel CAD. T2* BOLD is superior to semi-quantitative perfusion imaging in analyzing myocardial ischemia without stress.</p>","PeriodicalId":20817,"journal":{"name":"Radiologia Medica","volume":" ","pages":"1184-1196"},"PeriodicalIF":9.7000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The association between cardiac T2*BOLD and quantitative flow ratio (QFR) in the diagnosis of stenotic coronary arteries in patients with multi-vessel coronary artery disease.\",\"authors\":\"Lei Zhao, Bing-Hua Chen, Hui Tang, Yong-Yi Wang, Zi-Yi Gu, Dong-Aolei An, Lian-Ming Wu, Song Xue\",\"doi\":\"10.1007/s11547-024-01847-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>T2*BOLD is based on myocardial deoxyhemoglobin content to reflect the state of myocardial oxygenation. Quantitative flow ratio is a tool for assessing coronary blood flow based on invasive coronary angiography.</p><p><strong>Purpose: </strong>This study aimed to evaluate the correlation between T2*BOLD and QFR in the diagnosis of stenotic coronary arteries in patients with multi-vessel coronary artery disease.</p><p><strong>Methods: </strong>Fifty patients with MVCAD with at least 1 significant coronary artery stenosis (diameter stenosis > 50%) and 21 healthy control subjects underwent coronary angiography combined with QFR measurements and cardiovascular magnetic resonance (CMR). QFR ≤ 0.80 was considered to indicate the presence of hemodynamic obstruction.</p><p><strong>Results: </strong>Totally 60 (54%) obstructive vessels had hemodynamic change. Between stenotic coronary arteries (QFR ≤ 0.8) and normal vessels, T2*BOLD showed AUCs of 0.97, 0.69, and 0.91 for left anterior descending (LAD), left circumflex (LCX) and right coronary (RCA) arteries and PI displayed AUCs of 0.89, 0.77 and 0.90 (all p > 0.05, except for LAD). The AUCs of T2*BOLD between stenotic coronary arteries (QFR > 0.8) and normal vessels were 0.86, 0.72, and 0.85 for LAD, LCX and RCA; while, PI showed AUCs of 0.93, 0.86, and 0.88, respectively (p > 0.05). Moreover, T2*BOLD displayed AUCs of 0.96, 0.74, and 0.91 for coronary arteries as before between coronary arteries with stenosis (QFR ≤ 0.8 and > 0.8), but the mean PI of LAD, LCX and RCA showed no significant differences between them.</p><p><strong>Conclusion: </strong>T2* BOLD and QFR have good correlation in diagnosing stenotic coronary arteries with hemodynamic changes in patients with stable multi-vessel CAD. T2* BOLD is superior to semi-quantitative perfusion imaging in analyzing myocardial ischemia without stress.</p>\",\"PeriodicalId\":20817,\"journal\":{\"name\":\"Radiologia Medica\",\"volume\":\" \",\"pages\":\"1184-1196\"},\"PeriodicalIF\":9.7000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiologia Medica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11547-024-01847-2\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiologia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11547-024-01847-2","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
The association between cardiac T2*BOLD and quantitative flow ratio (QFR) in the diagnosis of stenotic coronary arteries in patients with multi-vessel coronary artery disease.
Background: T2*BOLD is based on myocardial deoxyhemoglobin content to reflect the state of myocardial oxygenation. Quantitative flow ratio is a tool for assessing coronary blood flow based on invasive coronary angiography.
Purpose: This study aimed to evaluate the correlation between T2*BOLD and QFR in the diagnosis of stenotic coronary arteries in patients with multi-vessel coronary artery disease.
Methods: Fifty patients with MVCAD with at least 1 significant coronary artery stenosis (diameter stenosis > 50%) and 21 healthy control subjects underwent coronary angiography combined with QFR measurements and cardiovascular magnetic resonance (CMR). QFR ≤ 0.80 was considered to indicate the presence of hemodynamic obstruction.
Results: Totally 60 (54%) obstructive vessels had hemodynamic change. Between stenotic coronary arteries (QFR ≤ 0.8) and normal vessels, T2*BOLD showed AUCs of 0.97, 0.69, and 0.91 for left anterior descending (LAD), left circumflex (LCX) and right coronary (RCA) arteries and PI displayed AUCs of 0.89, 0.77 and 0.90 (all p > 0.05, except for LAD). The AUCs of T2*BOLD between stenotic coronary arteries (QFR > 0.8) and normal vessels were 0.86, 0.72, and 0.85 for LAD, LCX and RCA; while, PI showed AUCs of 0.93, 0.86, and 0.88, respectively (p > 0.05). Moreover, T2*BOLD displayed AUCs of 0.96, 0.74, and 0.91 for coronary arteries as before between coronary arteries with stenosis (QFR ≤ 0.8 and > 0.8), but the mean PI of LAD, LCX and RCA showed no significant differences between them.
Conclusion: T2* BOLD and QFR have good correlation in diagnosing stenotic coronary arteries with hemodynamic changes in patients with stable multi-vessel CAD. T2* BOLD is superior to semi-quantitative perfusion imaging in analyzing myocardial ischemia without stress.
期刊介绍:
Felice Perussia founded La radiologia medica in 1914. It is a peer-reviewed journal and serves as the official journal of the Italian Society of Medical and Interventional Radiology (SIRM). The primary purpose of the journal is to disseminate information related to Radiology, especially advancements in diagnostic imaging and related disciplines. La radiologia medica welcomes original research on both fundamental and clinical aspects of modern radiology, with a particular focus on diagnostic and interventional imaging techniques. It also covers topics such as radiotherapy, nuclear medicine, radiobiology, health physics, and artificial intelligence in the context of clinical implications. The journal includes various types of contributions such as original articles, review articles, editorials, short reports, and letters to the editor. With an esteemed Editorial Board and a selection of insightful reports, the journal is an indispensable resource for radiologists and professionals in related fields. Ultimately, La radiologia medica aims to serve as a platform for international collaboration and knowledge sharing within the radiological community.