使用超轻添加硅胶材料重衬的两步式印模的尺寸精度。

Q3 Dentistry
Frontiers in Dentistry Pub Date : 2024-05-20 eCollection Date: 2024-01-01 DOI:10.18502/fid.v21i17.15550
Alireza Jafari, Esmat Mombeini, Leila Payaminia, Elaheh Beyabanaki, Rahim Tahmasebi
{"title":"使用超轻添加硅胶材料重衬的两步式印模的尺寸精度。","authors":"Alireza Jafari, Esmat Mombeini, Leila Payaminia, Elaheh Beyabanaki, Rahim Tahmasebi","doi":"10.18502/fid.v21i17.15550","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objectives:</b> Some small defects may remain in the impression after making a two-step putty-light body impression. The aim of this study was to evaluate and compare the dimensional accuracy of 2-step and relined 2-step (3-step) putty-light body impressions. <b>Materials and Methods:</b> In this in vitro study, 30 impressions were made with putty, light body, and extra-light body addition silicone materials using the 2-step and 3-step impression techniques (N=15). An epoxy resin master model was made duplicating a maxillary typodont with left first premolar and first molar teeth prepared with a shoulder finish line and truncated pyramidal-shaped indices in the mid-palate and third molar sites. In addition to creating a reference digital model by scanning the master model, 30 master casts were scanned to produce digital models. The anteroposterior (AP) and cross-sectional (CS) dimensional accuracy of the models were compared with the master model using linear measurements. Moreover, tooth size measurements were made and compared using the root mean square (RMS). Two-sample t-test was applied to analyze the data (α=0.05). <b>Results:</b> The mean AP and RMS differences between the two study groups were not significant (P>0.05). However, the CS difference between the two groups was significant (P<0.001), and the 3-step impression technique showed smaller discrepancies in comparison to the master model. <b>Conclusion:</b> There was no significant difference in accuracy of the two techniques for single-unit and multiple-unit preparations. The 3-step impression technique had a higher CS dimensional accuracy.</p>","PeriodicalId":12445,"journal":{"name":"Frontiers in Dentistry","volume":"21 ","pages":"17"},"PeriodicalIF":0.0000,"publicationDate":"2024-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11236484/pdf/","citationCount":"0","resultStr":"{\"title\":\"Dimensional Accuracy of Two-Step Impressions Relined with Extra-Light Addition Silicone Material.\",\"authors\":\"Alireza Jafari, Esmat Mombeini, Leila Payaminia, Elaheh Beyabanaki, Rahim Tahmasebi\",\"doi\":\"10.18502/fid.v21i17.15550\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objectives:</b> Some small defects may remain in the impression after making a two-step putty-light body impression. The aim of this study was to evaluate and compare the dimensional accuracy of 2-step and relined 2-step (3-step) putty-light body impressions. <b>Materials and Methods:</b> In this in vitro study, 30 impressions were made with putty, light body, and extra-light body addition silicone materials using the 2-step and 3-step impression techniques (N=15). An epoxy resin master model was made duplicating a maxillary typodont with left first premolar and first molar teeth prepared with a shoulder finish line and truncated pyramidal-shaped indices in the mid-palate and third molar sites. In addition to creating a reference digital model by scanning the master model, 30 master casts were scanned to produce digital models. The anteroposterior (AP) and cross-sectional (CS) dimensional accuracy of the models were compared with the master model using linear measurements. Moreover, tooth size measurements were made and compared using the root mean square (RMS). Two-sample t-test was applied to analyze the data (α=0.05). <b>Results:</b> The mean AP and RMS differences between the two study groups were not significant (P>0.05). However, the CS difference between the two groups was significant (P<0.001), and the 3-step impression technique showed smaller discrepancies in comparison to the master model. <b>Conclusion:</b> There was no significant difference in accuracy of the two techniques for single-unit and multiple-unit preparations. The 3-step impression technique had a higher CS dimensional accuracy.</p>\",\"PeriodicalId\":12445,\"journal\":{\"name\":\"Frontiers in Dentistry\",\"volume\":\"21 \",\"pages\":\"17\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11236484/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers in Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18502/fid.v21i17.15550\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/fid.v21i17.15550","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目标:在制作两步式腻子轻体印模后,印模中可能会残留一些小缺陷。本研究的目的是评估和比较两步式和再衬两步式(三步式)腻子轻体印模的尺寸精度。材料和方法:在这项体外研究中,使用 2 步法和 3 步法印模技术,使用腻子、轻体和超轻体添加硅胶材料制作了 30 个印模(N=15)。制作了一个环氧树脂主模型,复制了左侧第一前磨牙和第一磨牙的上颌正畸,在中腭和第三磨牙部位制备了肩部完成线和截断的金字塔形指数。除了通过扫描主模型创建参考数字模型外,还扫描了 30 个铸模以制作数字模型。通过线性测量将模型的前后(AP)和横截面(CS)尺寸精度与主模型进行比较。此外,还进行了牙齿尺寸测量,并使用均方根(RMS)进行比较。数据分析采用双样本 t 检验(α=0.05)。结果:两个研究组的平均 AP 和 RMS 差异不显著(P>0.05)。然而,两组之间的 CS 差异显著(PC结论:两组之间的 CS 差异显著(P>0.05),而 AP 差异显著(P>0.05):两种技术在单义齿和多义齿预备的准确性上没有明显差异。三步印模技术的 CS 尺寸准确度更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dimensional Accuracy of Two-Step Impressions Relined with Extra-Light Addition Silicone Material.

Objectives: Some small defects may remain in the impression after making a two-step putty-light body impression. The aim of this study was to evaluate and compare the dimensional accuracy of 2-step and relined 2-step (3-step) putty-light body impressions. Materials and Methods: In this in vitro study, 30 impressions were made with putty, light body, and extra-light body addition silicone materials using the 2-step and 3-step impression techniques (N=15). An epoxy resin master model was made duplicating a maxillary typodont with left first premolar and first molar teeth prepared with a shoulder finish line and truncated pyramidal-shaped indices in the mid-palate and third molar sites. In addition to creating a reference digital model by scanning the master model, 30 master casts were scanned to produce digital models. The anteroposterior (AP) and cross-sectional (CS) dimensional accuracy of the models were compared with the master model using linear measurements. Moreover, tooth size measurements were made and compared using the root mean square (RMS). Two-sample t-test was applied to analyze the data (α=0.05). Results: The mean AP and RMS differences between the two study groups were not significant (P>0.05). However, the CS difference between the two groups was significant (P<0.001), and the 3-step impression technique showed smaller discrepancies in comparison to the master model. Conclusion: There was no significant difference in accuracy of the two techniques for single-unit and multiple-unit preparations. The 3-step impression technique had a higher CS dimensional accuracy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Frontiers in Dentistry
Frontiers in Dentistry Dentistry-General Dentistry
CiteScore
1.00
自引率
0.00%
发文量
34
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信