{"title":"解决 \"W 形 \"P100 波形:是正常还是异常?","authors":"Maya Martin-Gonzalez, Aatif M Husain","doi":"10.1097/WNP.0000000000001102","DOIUrl":null,"url":null,"abstract":"<p><strong>Summary: </strong>Pattern-reversal visual evoked potentials are used to assess the visual pathways. The main waveform of interest is the P100, which is best recorded with electrodes over the mid-occipital region. Most often, the P100 waveform has negative-positive-negative components. Occasionally, it is \"W-shaped,\" with positive-negative-positive components. Although most often a W-shaped P100 waveform indicates an abnormality in the visual pathway, occasionally, it can be normal. A case is presented in which a W-shaped P100 waveform is seen after monocular full-field stimulation of both eyes with 30' checks. To resolve this finding, the pattern-reversal visual evoked potentials is repeated with 60' and 15' checks. With 15' checks a single typical single-peak P100 waveform is seen with normal latency. Evaluation of a W-shaped P100 waveform should involve analysis of various montages, stimulation with different check sizes, and hemifield stimulation to confirm whether the W-shaped waveform is normal or abnormal.</p>","PeriodicalId":15516,"journal":{"name":"Journal of Clinical Neurophysiology","volume":" ","pages":"87-91"},"PeriodicalIF":2.3000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Resolving a \\\"W-Shaped\\\" P100 Waveform: Is It Normal or Abnormal?\",\"authors\":\"Maya Martin-Gonzalez, Aatif M Husain\",\"doi\":\"10.1097/WNP.0000000000001102\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Summary: </strong>Pattern-reversal visual evoked potentials are used to assess the visual pathways. The main waveform of interest is the P100, which is best recorded with electrodes over the mid-occipital region. Most often, the P100 waveform has negative-positive-negative components. Occasionally, it is \\\"W-shaped,\\\" with positive-negative-positive components. Although most often a W-shaped P100 waveform indicates an abnormality in the visual pathway, occasionally, it can be normal. A case is presented in which a W-shaped P100 waveform is seen after monocular full-field stimulation of both eyes with 30' checks. To resolve this finding, the pattern-reversal visual evoked potentials is repeated with 60' and 15' checks. With 15' checks a single typical single-peak P100 waveform is seen with normal latency. Evaluation of a W-shaped P100 waveform should involve analysis of various montages, stimulation with different check sizes, and hemifield stimulation to confirm whether the W-shaped waveform is normal or abnormal.</p>\",\"PeriodicalId\":15516,\"journal\":{\"name\":\"Journal of Clinical Neurophysiology\",\"volume\":\" \",\"pages\":\"87-91\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Neurophysiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/WNP.0000000000001102\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Neurophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/WNP.0000000000001102","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
摘要
摘要:模式反转视觉诱发电位用于评估视觉通路。主要的波形是 P100,最好用枕骨中段的电极记录。大多数情况下,P100 波形具有负-正-负成分。偶尔也会出现 "W 形",即有正-负-正成分。虽然 W 型 P100 波形通常表示视觉通路异常,但偶尔也可能是正常的。本报告中的一个病例显示,用 30' 检查对双眼进行单眼全视野刺激后,P100 波形呈 W 形。为了解决这个问题,我们用 60' 和 15' 检查重复了模式反转视觉诱发电位。在 15' 检查中,可以看到一个典型的单峰 P100 波形,潜伏期正常。对 W 形 P100 波形的评估应包括分析各种蒙太奇、使用不同大小的检查和半视野刺激,以确认 W 形波形是正常还是异常。
Resolving a "W-Shaped" P100 Waveform: Is It Normal or Abnormal?
Summary: Pattern-reversal visual evoked potentials are used to assess the visual pathways. The main waveform of interest is the P100, which is best recorded with electrodes over the mid-occipital region. Most often, the P100 waveform has negative-positive-negative components. Occasionally, it is "W-shaped," with positive-negative-positive components. Although most often a W-shaped P100 waveform indicates an abnormality in the visual pathway, occasionally, it can be normal. A case is presented in which a W-shaped P100 waveform is seen after monocular full-field stimulation of both eyes with 30' checks. To resolve this finding, the pattern-reversal visual evoked potentials is repeated with 60' and 15' checks. With 15' checks a single typical single-peak P100 waveform is seen with normal latency. Evaluation of a W-shaped P100 waveform should involve analysis of various montages, stimulation with different check sizes, and hemifield stimulation to confirm whether the W-shaped waveform is normal or abnormal.
期刊介绍:
The Journal of Clinical Neurophysiology features both topical reviews and original research in both central and peripheral neurophysiology, as related to patient evaluation and treatment.
Official Journal of the American Clinical Neurophysiology Society.