{"title":"人血清中游离血红蛋白(有别于血红蛋白-aptoglobin 复合物)的定量方法。","authors":"","doi":"10.1016/j.ab.2024.115601","DOIUrl":null,"url":null,"abstract":"<div><p>The measurement of free hemoglobin (free Hb) in blood is crucial for assessing the risk of organ damage in patients with hemolytic diseases. However, the colorimetric method, commonly used in clinical practice, does not distinguish between free Hb and the hemoglobin-haptoglobin complex (Hb-Hp) in the blood, instead reflecting the total Hb level. Although size-exclusion high-performance liquid chromatography (SEC-HPLC) can specifically measure free Hb, its clinical use is limited by long assay times. Here, we developed a novel assay method for the rapid quantification of free Hb in serum, distinguishing it from Hb-Hp, using a latex agglutination immunoturbidimetric assay (LATIA). This method could be used to measure free Hb in sera in the range of 1–100 μg/mL in approximately 15 min using an automatic biochemistry analyzer. Using Hb-spiked serum samples from healthy adults, there was a high correlation with Hb levels determined using the newly developed method and SEC-HPLC, indicating a high specificity for free Hb. This novel assay can be used to monitor levels of free Hb in patients with various hemolytic diseases and to design therapeutic strategies based on measured values. However, further studies are required to assess its clinical performance.</p></div>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0003269724001453/pdfft?md5=3b9e547a6e9b572079f717b830f81c51&pid=1-s2.0-S0003269724001453-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Method for quantifying free hemoglobin, distinct from the hemoglobin-haptoglobin complex, in human serum\",\"authors\":\"\",\"doi\":\"10.1016/j.ab.2024.115601\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The measurement of free hemoglobin (free Hb) in blood is crucial for assessing the risk of organ damage in patients with hemolytic diseases. However, the colorimetric method, commonly used in clinical practice, does not distinguish between free Hb and the hemoglobin-haptoglobin complex (Hb-Hp) in the blood, instead reflecting the total Hb level. Although size-exclusion high-performance liquid chromatography (SEC-HPLC) can specifically measure free Hb, its clinical use is limited by long assay times. Here, we developed a novel assay method for the rapid quantification of free Hb in serum, distinguishing it from Hb-Hp, using a latex agglutination immunoturbidimetric assay (LATIA). This method could be used to measure free Hb in sera in the range of 1–100 μg/mL in approximately 15 min using an automatic biochemistry analyzer. Using Hb-spiked serum samples from healthy adults, there was a high correlation with Hb levels determined using the newly developed method and SEC-HPLC, indicating a high specificity for free Hb. This novel assay can be used to monitor levels of free Hb in patients with various hemolytic diseases and to design therapeutic strategies based on measured values. However, further studies are required to assess its clinical performance.</p></div>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-07-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0003269724001453/pdfft?md5=3b9e547a6e9b572079f717b830f81c51&pid=1-s2.0-S0003269724001453-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0003269724001453\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003269724001453","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
Method for quantifying free hemoglobin, distinct from the hemoglobin-haptoglobin complex, in human serum
The measurement of free hemoglobin (free Hb) in blood is crucial for assessing the risk of organ damage in patients with hemolytic diseases. However, the colorimetric method, commonly used in clinical practice, does not distinguish between free Hb and the hemoglobin-haptoglobin complex (Hb-Hp) in the blood, instead reflecting the total Hb level. Although size-exclusion high-performance liquid chromatography (SEC-HPLC) can specifically measure free Hb, its clinical use is limited by long assay times. Here, we developed a novel assay method for the rapid quantification of free Hb in serum, distinguishing it from Hb-Hp, using a latex agglutination immunoturbidimetric assay (LATIA). This method could be used to measure free Hb in sera in the range of 1–100 μg/mL in approximately 15 min using an automatic biochemistry analyzer. Using Hb-spiked serum samples from healthy adults, there was a high correlation with Hb levels determined using the newly developed method and SEC-HPLC, indicating a high specificity for free Hb. This novel assay can be used to monitor levels of free Hb in patients with various hemolytic diseases and to design therapeutic strategies based on measured values. However, further studies are required to assess its clinical performance.