Helene Clogenson, Charlotte De Marne, Katia Desplobain, Amélie Le Gouge, Marc Laffon, Serge Maia
{"title":"使用 DosiBadge 监控手术室内手术人员的 X 射线照射情况。","authors":"Helene Clogenson, Charlotte De Marne, Katia Desplobain, Amélie Le Gouge, Marc Laffon, Serge Maia","doi":"10.1088/1361-6498/ad5f37","DOIUrl":null,"url":null,"abstract":"<p><p>Surgical procedures involving the use of x-rays in the operating room (OR) have increased in recent years, thereby increasing the exposure of OR staff to ionizing radiation. An individual dosimeter makes it possible to record the radiation exposure to which these personnel are exposed, but there is a lack of compliance in the wearing of these dosimeters for several practical reasons. This makes the dose results obtained unreliable. To try to improve the rate of dosimeter wearing in the OR, the Dosibadge project studied the association of the individual dosimeter with the hospital access badge, forming the Dosibadge. Through a study performed at the Tours University Hospital in eight different ORs for two consecutive periods of 3 months. The results show a significant increase in the systematic use of the dosimeter thanks to the Dosibadge, which improves the reliability of the doses obtained on the dosimeters and the monitoring of personnel. The increase is especially marked with clinicians. Following these results and the very positive feedback to this first single-centre study, we are then planning a second multicentre study to validate our proof of concept on different sites, with the three brands of individual dosimeters used in France i.e. dosimeters supplied by Dosilab; Landauer and IRSN.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Monitoring of surgical staff x-ray exposure in the operating room with DosiBadge.\",\"authors\":\"Helene Clogenson, Charlotte De Marne, Katia Desplobain, Amélie Le Gouge, Marc Laffon, Serge Maia\",\"doi\":\"10.1088/1361-6498/ad5f37\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Surgical procedures involving the use of x-rays in the operating room (OR) have increased in recent years, thereby increasing the exposure of OR staff to ionizing radiation. An individual dosimeter makes it possible to record the radiation exposure to which these personnel are exposed, but there is a lack of compliance in the wearing of these dosimeters for several practical reasons. This makes the dose results obtained unreliable. To try to improve the rate of dosimeter wearing in the OR, the Dosibadge project studied the association of the individual dosimeter with the hospital access badge, forming the Dosibadge. Through a study performed at the Tours University Hospital in eight different ORs for two consecutive periods of 3 months. The results show a significant increase in the systematic use of the dosimeter thanks to the Dosibadge, which improves the reliability of the doses obtained on the dosimeters and the monitoring of personnel. The increase is especially marked with clinicians. Following these results and the very positive feedback to this first single-centre study, we are then planning a second multicentre study to validate our proof of concept on different sites, with the three brands of individual dosimeters used in France i.e. dosimeters supplied by Dosilab; Landauer and IRSN.</p>\",\"PeriodicalId\":50068,\"journal\":{\"name\":\"Journal of Radiological Protection\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-07-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Radiological Protection\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1088/1361-6498/ad5f37\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ad5f37","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
摘要
近年来,在手术室使用 X 射线的外科手术越来越多,从而增加了手术室工作人员暴露于电离辐射的机会。个人剂量计可以记录这些人员所受的辐照剂量,但由于一些实际原因,这些剂量计的佩戴并不合规。这就使得得到的剂量结果不可靠。为了提高手术室内剂量计的佩戴率,Dosibadge 项目研究了如何将个人剂量计与医院出入证结合起来,形成 Dosibadge。图尔大学医院在 8 个不同的手术室进行了连续两个月的研究。研究结果表明,由于使用了 Dosibadge,剂量计的系统使用率有了显著提高,从而提高了剂量计所获剂量的可靠性和对人员的监控。临床医生的使用率提高尤为明显。根据这些结果以及对第一项单中心研究的积极反馈,我们正计划进行第二项多中心研究,以验证我们在法国使用的三种品牌的单个剂量计在不同地点的概念验证。
Monitoring of surgical staff x-ray exposure in the operating room with DosiBadge.
Surgical procedures involving the use of x-rays in the operating room (OR) have increased in recent years, thereby increasing the exposure of OR staff to ionizing radiation. An individual dosimeter makes it possible to record the radiation exposure to which these personnel are exposed, but there is a lack of compliance in the wearing of these dosimeters for several practical reasons. This makes the dose results obtained unreliable. To try to improve the rate of dosimeter wearing in the OR, the Dosibadge project studied the association of the individual dosimeter with the hospital access badge, forming the Dosibadge. Through a study performed at the Tours University Hospital in eight different ORs for two consecutive periods of 3 months. The results show a significant increase in the systematic use of the dosimeter thanks to the Dosibadge, which improves the reliability of the doses obtained on the dosimeters and the monitoring of personnel. The increase is especially marked with clinicians. Following these results and the very positive feedback to this first single-centre study, we are then planning a second multicentre study to validate our proof of concept on different sites, with the three brands of individual dosimeters used in France i.e. dosimeters supplied by Dosilab; Landauer and IRSN.
期刊介绍:
Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments.
The journal encourages publication of data and code as well as results.