{"title":"在印度 CSIR-NPL 对 MJTC 进行内部相互比较,以便根据低频电压和电流国家标准分配交直流转换差值","authors":"Sunidhi Luthra, Swati Kumari, Archana Sahu, Avni Khatkar, Bijendra Pal, Saood Ahmad","doi":"10.1007/s12647-024-00735-4","DOIUrl":null,"url":null,"abstract":"<div><p>Multijunction thermal converters (MJTCs) are used worldwide by the leading NMIs (National Metrological Institute) as primary Standard for the establishment of low frequency (LF) AC voltage and current parameters. The MJTC is an electrothermic device that works on the principle of Joule’s heating law. At NPLI (National Physical Laboratory, India), we have kept a bank of four MJTCs with identical characteristics. The AC–DC transfer difference of these MJTCs is determined over a frequency range of 10 Hz–1 MHz. The operating range of MJTC is 2 V and 5 mA. The uncertainty in assigning AC/DC transfer difference varies from ± 5 ppm to ± 25 ppm for both voltage and current range. This paper presents the in-house intercomparison of MJTCs to evaluate relative AC/DC transfer difference for establishment of primary standard of LF voltage and current.</p></div>","PeriodicalId":689,"journal":{"name":"MAPAN","volume":"39 3","pages":"731 - 737"},"PeriodicalIF":1.0000,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In-house Intercomparison of MJTCs for Assigning AC/DC Transfer Difference to National Standard of LF Voltage and Current at CSIR-NPL India\",\"authors\":\"Sunidhi Luthra, Swati Kumari, Archana Sahu, Avni Khatkar, Bijendra Pal, Saood Ahmad\",\"doi\":\"10.1007/s12647-024-00735-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Multijunction thermal converters (MJTCs) are used worldwide by the leading NMIs (National Metrological Institute) as primary Standard for the establishment of low frequency (LF) AC voltage and current parameters. The MJTC is an electrothermic device that works on the principle of Joule’s heating law. At NPLI (National Physical Laboratory, India), we have kept a bank of four MJTCs with identical characteristics. The AC–DC transfer difference of these MJTCs is determined over a frequency range of 10 Hz–1 MHz. The operating range of MJTC is 2 V and 5 mA. The uncertainty in assigning AC/DC transfer difference varies from ± 5 ppm to ± 25 ppm for both voltage and current range. This paper presents the in-house intercomparison of MJTCs to evaluate relative AC/DC transfer difference for establishment of primary standard of LF voltage and current.</p></div>\",\"PeriodicalId\":689,\"journal\":{\"name\":\"MAPAN\",\"volume\":\"39 3\",\"pages\":\"731 - 737\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-07-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"MAPAN\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s12647-024-00735-4\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"MAPAN","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s12647-024-00735-4","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
In-house Intercomparison of MJTCs for Assigning AC/DC Transfer Difference to National Standard of LF Voltage and Current at CSIR-NPL India
Multijunction thermal converters (MJTCs) are used worldwide by the leading NMIs (National Metrological Institute) as primary Standard for the establishment of low frequency (LF) AC voltage and current parameters. The MJTC is an electrothermic device that works on the principle of Joule’s heating law. At NPLI (National Physical Laboratory, India), we have kept a bank of four MJTCs with identical characteristics. The AC–DC transfer difference of these MJTCs is determined over a frequency range of 10 Hz–1 MHz. The operating range of MJTC is 2 V and 5 mA. The uncertainty in assigning AC/DC transfer difference varies from ± 5 ppm to ± 25 ppm for both voltage and current range. This paper presents the in-house intercomparison of MJTCs to evaluate relative AC/DC transfer difference for establishment of primary standard of LF voltage and current.
期刊介绍:
MAPAN-Journal Metrology Society of India is a quarterly publication. It is exclusively devoted to Metrology (Scientific, Industrial or Legal). It has been fulfilling an important need of Metrologists and particularly of quality practitioners by publishing exclusive articles on scientific, industrial and legal metrology.
The journal publishes research communication or technical articles of current interest in measurement science; original work, tutorial or survey papers in any metrology related area; reviews and analytical studies in metrology; case studies on reliability, uncertainty in measurements; and reports and results of intercomparison and proficiency testing.