在人工耳蜗植入术中使用 SmartNav 技术:优化电极放置评估的效率。

IF 1.4 Q2 OTORHINOLARYNGOLOGY
COCHLEAR IMPLANTS INTERNATIONAL Pub Date : 2024-07-01 Epub Date: 2024-07-03 DOI:10.1080/14670100.2024.2370679
Jaimee Cooper, Katrina R Stidham, Samantha Morgan, Mindy Schmelzer, Regina Albinus
{"title":"在人工耳蜗植入术中使用 SmartNav 技术:优化电极放置评估的效率。","authors":"Jaimee Cooper, Katrina R Stidham, Samantha Morgan, Mindy Schmelzer, Regina Albinus","doi":"10.1080/14670100.2024.2370679","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Proper electrode placement is essential for favorable hearing outcomes following cochlear implantation. Though often used, traditional intraoperative X-ray imaging is time consuming, exposes patients and staff to radiation, and poses interpretational challenges. The Nucleus® SmartNav System, utilizes electrode voltage telemetry (EVT) to analyze the positioning of the electrode array intraoperatively. This study investigates the efficacy of SmartNav in optimizing the efficiency and accuracy of assessing electrode placement.</p><p><strong>Methods: </strong>This prospective clinical study analyzed placement of 50 consecutive Cochlear Corporation cochlear implants conducted at a single institution between March of 2022 and June of 2023. Placement check of electrode array using SmartNav and X-ray was completed and individually assessed. A comparative analysis of SmartNav and X-ray completion times for electrode placement assessment was conducted.</p><p><strong>Results: </strong>Subjects included nine ears with abnormal anatomy and three reimplants. SmartNav placement check required a total time of 2.12 min compared to X-ray imaging at 14.23 min (<i>p</i> = 1.6E-16, CI 95%). Both SmartNav and X-ray had excellent sensitivity of 100% in identifying appropriate electrode position (<i>p</i> = 1.0). Tip fold-over was identified using both modalities in 3 cases with noted easier interpretation using SmartNav.</p><p><strong>Conclusion: </strong>The Nucleus® SmartNav System significantly outperformed traditional X-ray imaging, offering a faster and more straightforward approach to assessing electrode positioning during cochlear implant surgery, thereby enhancing surgical efficiency and patient safety.</p>","PeriodicalId":53553,"journal":{"name":"COCHLEAR IMPLANTS INTERNATIONAL","volume":" ","pages":"308-315"},"PeriodicalIF":1.4000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Utilization of SmartNav technology in cochlear implantation: optimizing efficiency in assessment of electrode placement.\",\"authors\":\"Jaimee Cooper, Katrina R Stidham, Samantha Morgan, Mindy Schmelzer, Regina Albinus\",\"doi\":\"10.1080/14670100.2024.2370679\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Proper electrode placement is essential for favorable hearing outcomes following cochlear implantation. Though often used, traditional intraoperative X-ray imaging is time consuming, exposes patients and staff to radiation, and poses interpretational challenges. The Nucleus® SmartNav System, utilizes electrode voltage telemetry (EVT) to analyze the positioning of the electrode array intraoperatively. This study investigates the efficacy of SmartNav in optimizing the efficiency and accuracy of assessing electrode placement.</p><p><strong>Methods: </strong>This prospective clinical study analyzed placement of 50 consecutive Cochlear Corporation cochlear implants conducted at a single institution between March of 2022 and June of 2023. Placement check of electrode array using SmartNav and X-ray was completed and individually assessed. A comparative analysis of SmartNav and X-ray completion times for electrode placement assessment was conducted.</p><p><strong>Results: </strong>Subjects included nine ears with abnormal anatomy and three reimplants. SmartNav placement check required a total time of 2.12 min compared to X-ray imaging at 14.23 min (<i>p</i> = 1.6E-16, CI 95%). Both SmartNav and X-ray had excellent sensitivity of 100% in identifying appropriate electrode position (<i>p</i> = 1.0). Tip fold-over was identified using both modalities in 3 cases with noted easier interpretation using SmartNav.</p><p><strong>Conclusion: </strong>The Nucleus® SmartNav System significantly outperformed traditional X-ray imaging, offering a faster and more straightforward approach to assessing electrode positioning during cochlear implant surgery, thereby enhancing surgical efficiency and patient safety.</p>\",\"PeriodicalId\":53553,\"journal\":{\"name\":\"COCHLEAR IMPLANTS INTERNATIONAL\",\"volume\":\" \",\"pages\":\"308-315\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"COCHLEAR IMPLANTS INTERNATIONAL\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/14670100.2024.2370679\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"COCHLEAR IMPLANTS INTERNATIONAL","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14670100.2024.2370679","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/3 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:正确的电极放置对于人工耳蜗植入术后获得良好的听力效果至关重要。传统的术中 X 射线成像虽然常用,但耗时长,患者和工作人员都会受到辐射,而且在解释上也存在挑战。Nucleus® SmartNav 系统利用电极电压遥测技术 (EVT) 分析术中电极阵列的定位。本研究探讨了 SmartNav 在优化电极位置评估的效率和准确性方面的功效:这项前瞻性临床研究分析了 2022 年 3 月至 2023 年 6 月期间在一家机构进行的 50 例连续人工耳蜗植入手术。使用 SmartNav 和 X 光完成了电极阵列的植入检查,并进行了单独评估。结果:研究对象包括九只解剖结构异常的耳朵和三只重新植入的耳朵。智能导航置放检查总共需要 2.12 分钟,而 X 光成像需要 14.23 分钟(P = 1.6E-16,CI 95%)。SmartNav 和 X 射线在识别适当电极位置方面的灵敏度均为 100%(p = 1.0)。在 3 个病例中,使用两种模式都能确定电极尖端折叠,而使用 SmartNav 则更容易解释:Nucleus® SmartNav 系统的性能明显优于传统的 X 光成像,为人工耳蜗植入手术中评估电极位置提供了更快、更直接的方法,从而提高了手术效率和患者安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Utilization of SmartNav technology in cochlear implantation: optimizing efficiency in assessment of electrode placement.

Objectives: Proper electrode placement is essential for favorable hearing outcomes following cochlear implantation. Though often used, traditional intraoperative X-ray imaging is time consuming, exposes patients and staff to radiation, and poses interpretational challenges. The Nucleus® SmartNav System, utilizes electrode voltage telemetry (EVT) to analyze the positioning of the electrode array intraoperatively. This study investigates the efficacy of SmartNav in optimizing the efficiency and accuracy of assessing electrode placement.

Methods: This prospective clinical study analyzed placement of 50 consecutive Cochlear Corporation cochlear implants conducted at a single institution between March of 2022 and June of 2023. Placement check of electrode array using SmartNav and X-ray was completed and individually assessed. A comparative analysis of SmartNav and X-ray completion times for electrode placement assessment was conducted.

Results: Subjects included nine ears with abnormal anatomy and three reimplants. SmartNav placement check required a total time of 2.12 min compared to X-ray imaging at 14.23 min (p = 1.6E-16, CI 95%). Both SmartNav and X-ray had excellent sensitivity of 100% in identifying appropriate electrode position (p = 1.0). Tip fold-over was identified using both modalities in 3 cases with noted easier interpretation using SmartNav.

Conclusion: The Nucleus® SmartNav System significantly outperformed traditional X-ray imaging, offering a faster and more straightforward approach to assessing electrode positioning during cochlear implant surgery, thereby enhancing surgical efficiency and patient safety.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
COCHLEAR IMPLANTS INTERNATIONAL
COCHLEAR IMPLANTS INTERNATIONAL Medicine-Otorhinolaryngology
CiteScore
3.10
自引率
0.00%
发文量
29
期刊介绍: Cochlear Implants International was founded as an interdisciplinary, peer-reviewed journal in response to the growing number of publications in the field of cochlear implants. It was designed to meet a need to include scientific contributions from all the disciplines that are represented in cochlear implant teams: audiology, medicine and surgery, speech therapy and speech pathology, psychology, hearing therapy, radiology, pathology, engineering and acoustics, teaching, and communication. The aim was to found a truly interdisciplinary journal, representing the full breadth of the field of cochlear implantation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信