利用深度学习超声心动图对儿童房间隔缺损进行智能诊断

Q1 Computer Science
Yiman LIU , Size HOU , Xiaoxiang HAN , Tongtong LIANG , Menghan HU , Xin WANG , Wei GU , Yuqi ZHANG , Qingli LI , Jiangang CHEN
{"title":"利用深度学习超声心动图对儿童房间隔缺损进行智能诊断","authors":"Yiman LIU ,&nbsp;Size HOU ,&nbsp;Xiaoxiang HAN ,&nbsp;Tongtong LIANG ,&nbsp;Menghan HU ,&nbsp;Xin WANG ,&nbsp;Wei GU ,&nbsp;Yuqi ZHANG ,&nbsp;Qingli LI ,&nbsp;Jiangang CHEN","doi":"10.1016/j.vrih.2023.05.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Atrial septal defect (ASD) is one of the most common congenital heart diseases. The diagnosis of ASD via transthoracic echocardiography is subjective and time-consuming.</p></div><div><h3>Methods</h3><p>The objective of this study was to evaluate the feasibility and accuracy of automatic detection of ASD in children based on color Doppler echocardiographic static images using end-to-end convolutional neural networks. The proposed depthwise separable convolution model identifies ASDs with static color Doppler images in a standard view. Among the standard views, we selected two echocardiographic views, i.e., the subcostal sagittal view of the atrium septum and the low parasternal four-chamber view. The developed ASD detection system was validated using a training set consisting of 396 echocardiographic images corresponding to 198 cases. Additionally, an independent test dataset of 112 images corresponding to 56 cases was used, including 101 cases with ASDs and 153 cases with normal hearts.</p></div><div><h3>Results</h3><p>The average area under the receiver operating characteristic curve, recall, precision, specificity, F1-score, and accuracy of the proposed ASD detection model were 91.99, 80.00, 82.22, 87.50, 79.57, and 83.04, respectively.</p></div><div><h3>Conclusions</h3><p>The proposed model can accurately and automatically identify ASD, providing a strong foundation for the intelligent diagnosis of congenital heart diseases.</p></div>","PeriodicalId":33538,"journal":{"name":"Virtual Reality Intelligent Hardware","volume":"6 3","pages":"Pages 217-225"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2096579623000244/pdfft?md5=3ade0d91e713f6555fd1c75181120add&pid=1-s2.0-S2096579623000244-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Intelligent diagnosis of atrial septal defect in children using echocardiography with deep learning\",\"authors\":\"Yiman LIU ,&nbsp;Size HOU ,&nbsp;Xiaoxiang HAN ,&nbsp;Tongtong LIANG ,&nbsp;Menghan HU ,&nbsp;Xin WANG ,&nbsp;Wei GU ,&nbsp;Yuqi ZHANG ,&nbsp;Qingli LI ,&nbsp;Jiangang CHEN\",\"doi\":\"10.1016/j.vrih.2023.05.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Atrial septal defect (ASD) is one of the most common congenital heart diseases. The diagnosis of ASD via transthoracic echocardiography is subjective and time-consuming.</p></div><div><h3>Methods</h3><p>The objective of this study was to evaluate the feasibility and accuracy of automatic detection of ASD in children based on color Doppler echocardiographic static images using end-to-end convolutional neural networks. The proposed depthwise separable convolution model identifies ASDs with static color Doppler images in a standard view. Among the standard views, we selected two echocardiographic views, i.e., the subcostal sagittal view of the atrium septum and the low parasternal four-chamber view. The developed ASD detection system was validated using a training set consisting of 396 echocardiographic images corresponding to 198 cases. Additionally, an independent test dataset of 112 images corresponding to 56 cases was used, including 101 cases with ASDs and 153 cases with normal hearts.</p></div><div><h3>Results</h3><p>The average area under the receiver operating characteristic curve, recall, precision, specificity, F1-score, and accuracy of the proposed ASD detection model were 91.99, 80.00, 82.22, 87.50, 79.57, and 83.04, respectively.</p></div><div><h3>Conclusions</h3><p>The proposed model can accurately and automatically identify ASD, providing a strong foundation for the intelligent diagnosis of congenital heart diseases.</p></div>\",\"PeriodicalId\":33538,\"journal\":{\"name\":\"Virtual Reality Intelligent Hardware\",\"volume\":\"6 3\",\"pages\":\"Pages 217-225\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2096579623000244/pdfft?md5=3ade0d91e713f6555fd1c75181120add&pid=1-s2.0-S2096579623000244-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Virtual Reality Intelligent Hardware\",\"FirstCategoryId\":\"1093\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2096579623000244\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Computer Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Virtual Reality Intelligent Hardware","FirstCategoryId":"1093","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2096579623000244","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Computer Science","Score":null,"Total":0}
引用次数: 0

摘要

背景房间隔缺损(ASD)是最常见的先天性心脏病之一。本研究的目的是评估使用端到端卷积神经网络根据彩色多普勒超声心动图静态图像自动检测儿童房间隔缺损的可行性和准确性。所提出的深度可分离卷积模型可通过标准视图中的静态彩色多普勒图像识别 ASD。在标准视图中,我们选择了两个超声心动图视图,即心房隔膜肋下矢状切面和胸骨旁四腔低切面。所开发的 ASD 检测系统通过由 198 个病例的 396 张超声心动图组成的训练集进行了验证。结果 ASD检测模型的平均接收者工作特征曲线下面积、召回率、精确率、特异性、F1-score和准确率分别为91.99、80.00、82.22、87.50、79.57和83.04。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intelligent diagnosis of atrial septal defect in children using echocardiography with deep learning

Background

Atrial septal defect (ASD) is one of the most common congenital heart diseases. The diagnosis of ASD via transthoracic echocardiography is subjective and time-consuming.

Methods

The objective of this study was to evaluate the feasibility and accuracy of automatic detection of ASD in children based on color Doppler echocardiographic static images using end-to-end convolutional neural networks. The proposed depthwise separable convolution model identifies ASDs with static color Doppler images in a standard view. Among the standard views, we selected two echocardiographic views, i.e., the subcostal sagittal view of the atrium septum and the low parasternal four-chamber view. The developed ASD detection system was validated using a training set consisting of 396 echocardiographic images corresponding to 198 cases. Additionally, an independent test dataset of 112 images corresponding to 56 cases was used, including 101 cases with ASDs and 153 cases with normal hearts.

Results

The average area under the receiver operating characteristic curve, recall, precision, specificity, F1-score, and accuracy of the proposed ASD detection model were 91.99, 80.00, 82.22, 87.50, 79.57, and 83.04, respectively.

Conclusions

The proposed model can accurately and automatically identify ASD, providing a strong foundation for the intelligent diagnosis of congenital heart diseases.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Virtual Reality  Intelligent Hardware
Virtual Reality Intelligent Hardware Computer Science-Computer Graphics and Computer-Aided Design
CiteScore
6.40
自引率
0.00%
发文量
35
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信