{"title":"V 波分流 MitraClip 研究的设计与原理","authors":"","doi":"10.1016/j.amjcard.2024.06.023","DOIUrl":null,"url":null,"abstract":"<div><p>Heart failure (HF) and moderate-to-severe mitral regurgitation (MR) with residual elevations in left atrial pressure (LAP) after MitraClip may remain symptomatic and experience subsequent HF readmissions. The V-Wave interatrial shunt system is a permanent interatrial septal implant that shunts blood from the left-to-right atrium and serves to continuously unload the left atrium. Although the V-Wave shunt has previously been studied in patients with HF, the safety and feasibility of its deployment at the time of the MitraClip procedure is unknown.</p><p>The V-Wave Shunt MitraClip Study (NCT04729933) is an early feasibility study that aims to demonstrate the safety and efficacy of implantation of the V-Wave shunt device at the time of MitraClip procedure. Patients with moderate-to-severe secondary MR with left ventricular ejection fraction 20% to 50% and New York Heart Association functional class III/IV symptoms despite optimal medical therapy, residual mean LAP ≥20 mm Hg after MitraClip, and mean LAP–right atrial pressure difference ≥5 mm Hg are included. The primary safety end point is a composite outcome of all-cause death, stroke, myocardial infarction device embolization, cardiac tamponade, or device-related re-intervention or surgery at 30 days. Patients will be followed up to 5 years. Enrollment is ongoing, with 30-day results expected by the end of 2024.</p><p>The V-Wave Shunt Mitraclip Study aims to demonstrate the safety and efficacy of the implantation of the V-Wave interatrial shunt device at the time of index MitraClip placement which may serve as an adjunctive method by which continuous left atrial unloading may be achieved.</p></div>","PeriodicalId":7705,"journal":{"name":"American Journal of Cardiology","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and Rationale of the V-Wave Shunt MitraClip Study\",\"authors\":\"\",\"doi\":\"10.1016/j.amjcard.2024.06.023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Heart failure (HF) and moderate-to-severe mitral regurgitation (MR) with residual elevations in left atrial pressure (LAP) after MitraClip may remain symptomatic and experience subsequent HF readmissions. The V-Wave interatrial shunt system is a permanent interatrial septal implant that shunts blood from the left-to-right atrium and serves to continuously unload the left atrium. Although the V-Wave shunt has previously been studied in patients with HF, the safety and feasibility of its deployment at the time of the MitraClip procedure is unknown.</p><p>The V-Wave Shunt MitraClip Study (NCT04729933) is an early feasibility study that aims to demonstrate the safety and efficacy of implantation of the V-Wave shunt device at the time of MitraClip procedure. Patients with moderate-to-severe secondary MR with left ventricular ejection fraction 20% to 50% and New York Heart Association functional class III/IV symptoms despite optimal medical therapy, residual mean LAP ≥20 mm Hg after MitraClip, and mean LAP–right atrial pressure difference ≥5 mm Hg are included. The primary safety end point is a composite outcome of all-cause death, stroke, myocardial infarction device embolization, cardiac tamponade, or device-related re-intervention or surgery at 30 days. Patients will be followed up to 5 years. Enrollment is ongoing, with 30-day results expected by the end of 2024.</p><p>The V-Wave Shunt Mitraclip Study aims to demonstrate the safety and efficacy of the implantation of the V-Wave interatrial shunt device at the time of index MitraClip placement which may serve as an adjunctive method by which continuous left atrial unloading may be achieved.</p></div>\",\"PeriodicalId\":7705,\"journal\":{\"name\":\"American Journal of Cardiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-06-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Cardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0002914924004594\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Cardiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0002914924004594","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Design and Rationale of the V-Wave Shunt MitraClip Study
Heart failure (HF) and moderate-to-severe mitral regurgitation (MR) with residual elevations in left atrial pressure (LAP) after MitraClip may remain symptomatic and experience subsequent HF readmissions. The V-Wave interatrial shunt system is a permanent interatrial septal implant that shunts blood from the left-to-right atrium and serves to continuously unload the left atrium. Although the V-Wave shunt has previously been studied in patients with HF, the safety and feasibility of its deployment at the time of the MitraClip procedure is unknown.
The V-Wave Shunt MitraClip Study (NCT04729933) is an early feasibility study that aims to demonstrate the safety and efficacy of implantation of the V-Wave shunt device at the time of MitraClip procedure. Patients with moderate-to-severe secondary MR with left ventricular ejection fraction 20% to 50% and New York Heart Association functional class III/IV symptoms despite optimal medical therapy, residual mean LAP ≥20 mm Hg after MitraClip, and mean LAP–right atrial pressure difference ≥5 mm Hg are included. The primary safety end point is a composite outcome of all-cause death, stroke, myocardial infarction device embolization, cardiac tamponade, or device-related re-intervention or surgery at 30 days. Patients will be followed up to 5 years. Enrollment is ongoing, with 30-day results expected by the end of 2024.
The V-Wave Shunt Mitraclip Study aims to demonstrate the safety and efficacy of the implantation of the V-Wave interatrial shunt device at the time of index MitraClip placement which may serve as an adjunctive method by which continuous left atrial unloading may be achieved.
期刊介绍:
Published 24 times a year, The American Journal of Cardiology® is an independent journal designed for cardiovascular disease specialists and internists with a subspecialty in cardiology throughout the world. AJC is an independent, scientific, peer-reviewed journal of original articles that focus on the practical, clinical approach to the diagnosis and treatment of cardiovascular disease. AJC has one of the fastest acceptance to publication times in Cardiology. Features report on systemic hypertension, methodology, drugs, pacing, arrhythmia, preventive cardiology, congestive heart failure, valvular heart disease, congenital heart disease, and cardiomyopathy. Also included are editorials, readers'' comments, and symposia.