使用双能 CT 和高场磁共振量化纳米羟基磷灰石与天然马羟基磷灰石的放射学特性。

IF 4.2 2区 医学 Q2 MEDICINE, RESEARCH & EXPERIMENTAL
Katarzyna Skierbiszewska DVM , Urszula Szałaj PhD Eng. , Bernard Turek DVM PhD DSc , Olena Sych PhD Eng. , Tomasz Jasiński DVM PhD , Witold Łojkowski Professor , Małgorzata Domino DVM MSc PhD DSc
{"title":"使用双能 CT 和高场磁共振量化纳米羟基磷灰石与天然马羟基磷灰石的放射学特性。","authors":"Katarzyna Skierbiszewska DVM ,&nbsp;Urszula Szałaj PhD Eng. ,&nbsp;Bernard Turek DVM PhD DSc ,&nbsp;Olena Sych PhD Eng. ,&nbsp;Tomasz Jasiński DVM PhD ,&nbsp;Witold Łojkowski Professor ,&nbsp;Małgorzata Domino DVM MSc PhD DSc","doi":"10.1016/j.nano.2024.102765","DOIUrl":null,"url":null,"abstract":"<div><p>In equine medicine, assisted bone regeneration, including use of biomaterial substitutes like hydroxyapatite (HAP), is crucial for addressing bone defects. To follow-up on the outcome of HAP-based bone defect treatment, the advancement in quantified diagnostic imaging protocols is needed. This study aimed to quantify and compare the radiological properties of the HAP graft and natural equine bone using Magnetic Resonance (MR) and Computed Tomography (CT), both Single (SECT) and Dual Energy (DECT). SECT and DECT, allow for the differentiation of three HAP grain sizes, by progressive increase in relative density (RD). SECT, DECT, and MR enable the differentiation between natural cortical bone and synthetic HAP graft by augmentation in Effective Z and material density (MD) in HAP/Water, Calcium/Water, and Water/Calcium reconstructions, alongside the reduction in T2 relaxation time. The proposed quantification provided valuable radiological insights into the composition of HAP grafts, which may be useful in follow-up bone defect treatment.</p></div>","PeriodicalId":19050,"journal":{"name":"Nanomedicine : nanotechnology, biology, and medicine","volume":null,"pages":null},"PeriodicalIF":4.2000,"publicationDate":"2024-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1549963424000340/pdfft?md5=33a6f4eeddd77a85bbe49e328545d946&pid=1-s2.0-S1549963424000340-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Radiological properties of nano-hydroxyapatite compared to natural equine hydroxyapatite quantified using dual-energy CT and high-field MR\",\"authors\":\"Katarzyna Skierbiszewska DVM ,&nbsp;Urszula Szałaj PhD Eng. ,&nbsp;Bernard Turek DVM PhD DSc ,&nbsp;Olena Sych PhD Eng. ,&nbsp;Tomasz Jasiński DVM PhD ,&nbsp;Witold Łojkowski Professor ,&nbsp;Małgorzata Domino DVM MSc PhD DSc\",\"doi\":\"10.1016/j.nano.2024.102765\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In equine medicine, assisted bone regeneration, including use of biomaterial substitutes like hydroxyapatite (HAP), is crucial for addressing bone defects. To follow-up on the outcome of HAP-based bone defect treatment, the advancement in quantified diagnostic imaging protocols is needed. This study aimed to quantify and compare the radiological properties of the HAP graft and natural equine bone using Magnetic Resonance (MR) and Computed Tomography (CT), both Single (SECT) and Dual Energy (DECT). SECT and DECT, allow for the differentiation of three HAP grain sizes, by progressive increase in relative density (RD). SECT, DECT, and MR enable the differentiation between natural cortical bone and synthetic HAP graft by augmentation in Effective Z and material density (MD) in HAP/Water, Calcium/Water, and Water/Calcium reconstructions, alongside the reduction in T2 relaxation time. The proposed quantification provided valuable radiological insights into the composition of HAP grafts, which may be useful in follow-up bone defect treatment.</p></div>\",\"PeriodicalId\":19050,\"journal\":{\"name\":\"Nanomedicine : nanotechnology, biology, and medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.2000,\"publicationDate\":\"2024-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1549963424000340/pdfft?md5=33a6f4eeddd77a85bbe49e328545d946&pid=1-s2.0-S1549963424000340-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nanomedicine : nanotechnology, biology, and medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1549963424000340\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nanomedicine : nanotechnology, biology, and medicine","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1549963424000340","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

在马医学中,辅助骨再生,包括使用羟基磷灰石(HAP)等生物材料替代品,对于解决骨缺损问题至关重要。为了跟踪基于 HAP 的骨缺损治疗结果,需要推进量化诊断成像方案。本研究旨在使用磁共振 (MR) 和计算机断层扫描 (CT)(包括单能 (SECT) 和双能 (DECT))量化和比较 HAP 移植骨和天然马骨的放射学特性。SECT 和 DECT 可通过相对密度 (RD) 的逐渐增加来区分三种 HAP 晶粒大小。通过增强 HAP/水、钙/水和水/钙重建中的有效 Z 值和材料密度 (MD),同时缩短 T2 弛豫时间,SECT、DECT 和 MR 能够区分天然皮质骨和合成 HAP 移植骨。所提出的量化方法为了解 HAP 移植物的组成提供了宝贵的放射学见解,这可能对后续骨缺损治疗有用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Radiological properties of nano-hydroxyapatite compared to natural equine hydroxyapatite quantified using dual-energy CT and high-field MR

Radiological properties of nano-hydroxyapatite compared to natural equine hydroxyapatite quantified using dual-energy CT and high-field MR

In equine medicine, assisted bone regeneration, including use of biomaterial substitutes like hydroxyapatite (HAP), is crucial for addressing bone defects. To follow-up on the outcome of HAP-based bone defect treatment, the advancement in quantified diagnostic imaging protocols is needed. This study aimed to quantify and compare the radiological properties of the HAP graft and natural equine bone using Magnetic Resonance (MR) and Computed Tomography (CT), both Single (SECT) and Dual Energy (DECT). SECT and DECT, allow for the differentiation of three HAP grain sizes, by progressive increase in relative density (RD). SECT, DECT, and MR enable the differentiation between natural cortical bone and synthetic HAP graft by augmentation in Effective Z and material density (MD) in HAP/Water, Calcium/Water, and Water/Calcium reconstructions, alongside the reduction in T2 relaxation time. The proposed quantification provided valuable radiological insights into the composition of HAP grafts, which may be useful in follow-up bone defect treatment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
11.10
自引率
0.00%
发文量
133
审稿时长
42 days
期刊介绍: The mission of Nanomedicine: Nanotechnology, Biology, and Medicine (Nanomedicine: NBM) is to promote the emerging interdisciplinary field of nanomedicine. Nanomedicine: NBM is an international, peer-reviewed journal presenting novel, significant, and interdisciplinary theoretical and experimental results related to nanoscience and nanotechnology in the life and health sciences. Content includes basic, translational, and clinical research addressing diagnosis, treatment, monitoring, prediction, and prevention of diseases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信