结合视频监控系统和 3D 激光扫描,对人类身高估算模型进行详细研究。

IF 1.5 4区 医学 Q2 MEDICINE, LEGAL
Claudio Ciampini MD, Federico Zomparelli PhD, Stefano Groutas
{"title":"结合视频监控系统和 3D 激光扫描,对人类身高估算模型进行详细研究。","authors":"Claudio Ciampini MD,&nbsp;Federico Zomparelli PhD,&nbsp;Stefano Groutas","doi":"10.1111/1556-4029.15564","DOIUrl":null,"url":null,"abstract":"<p>The increase of video surveillance systems has highlighted the interest in forensic anthropometric analysis of subjects who commit crimes and are captured by cameras during their criminal activities. There are different methodologies for human height estimation. Forensic researchers developed a methodological approach that allows the height of a subject to be estimated through a combined model of 3D laser scanning acquisition and video images acquired by video surveillance systems. The proposed study had highlighted three limits: not assessments had been made for image correction to limit the distortion effect, the method had been tested by only one laboratory and probably height assessment was dependent on the ergonomics. To overcome these limitations, in this paper the analysis was repeated by correcting the images to compare the new results obtained with the previous ones. Furthermore, the same methodological approach was applied by estimating the height of a mannequin, to limit the ergonomic effects, and proposing the same study to three different forensic laboratories to compare the results. The presented study demonstrates the reliability and repeatability of the system, as the results obtained by the three laboratories are very similar. They have obtained the same trend and the maximum estimate distance is approximately 6 cm. Furthermore, it has showed that the accuracy of results is dependent on image correction, which has little impact (approximately 1 cm more accurate on the corrected frame than the normal frame) on the height evaluation and they are not dependent to the ergonomics of the subject captured.</p>","PeriodicalId":15743,"journal":{"name":"Journal of forensic sciences","volume":"69 5","pages":"1887-1898"},"PeriodicalIF":1.5000,"publicationDate":"2024-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A detailed study on human height estimation model that combines video surveillance systems with 3D laser scanning\",\"authors\":\"Claudio Ciampini MD,&nbsp;Federico Zomparelli PhD,&nbsp;Stefano Groutas\",\"doi\":\"10.1111/1556-4029.15564\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The increase of video surveillance systems has highlighted the interest in forensic anthropometric analysis of subjects who commit crimes and are captured by cameras during their criminal activities. There are different methodologies for human height estimation. Forensic researchers developed a methodological approach that allows the height of a subject to be estimated through a combined model of 3D laser scanning acquisition and video images acquired by video surveillance systems. The proposed study had highlighted three limits: not assessments had been made for image correction to limit the distortion effect, the method had been tested by only one laboratory and probably height assessment was dependent on the ergonomics. To overcome these limitations, in this paper the analysis was repeated by correcting the images to compare the new results obtained with the previous ones. Furthermore, the same methodological approach was applied by estimating the height of a mannequin, to limit the ergonomic effects, and proposing the same study to three different forensic laboratories to compare the results. The presented study demonstrates the reliability and repeatability of the system, as the results obtained by the three laboratories are very similar. They have obtained the same trend and the maximum estimate distance is approximately 6 cm. Furthermore, it has showed that the accuracy of results is dependent on image correction, which has little impact (approximately 1 cm more accurate on the corrected frame than the normal frame) on the height evaluation and they are not dependent to the ergonomics of the subject captured.</p>\",\"PeriodicalId\":15743,\"journal\":{\"name\":\"Journal of forensic sciences\",\"volume\":\"69 5\",\"pages\":\"1887-1898\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of forensic sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/1556-4029.15564\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, LEGAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of forensic sciences","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/1556-4029.15564","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
引用次数: 0

摘要

视频监控系统的增加凸显了对犯罪活动中被摄像头捕捉到的犯罪对象进行法医人体测量分析的兴趣。人类身高估计有不同的方法。法医研究人员开发了一种方法,可以通过三维激光扫描采集和视频监控系统采集的视频图像的组合模型来估算被测者的身高。拟议的研究强调了三个局限性:没有对图像校正进行评估以限制失真效应;该方法仅在一家实验室进行过测试;身高评估可能取决于人体工程学。为了克服这些局限性,本文通过校正图像来重复分析,将新的结果与之前的结果进行比较。此外,为了限制人体工程学的影响,本文还采用了相同的方法,即估算人体模型的身高,并在三个不同的法医实验室进行相同的研究,以比较结果。这项研究证明了系统的可靠性和可重复性,因为三个实验室获得的结果非常相似。它们获得了相同的趋势,最大估计距离约为 6 厘米。此外,研究还表明,结果的准确性取决于图像校正,而图像校正对身高评估的影响很小(校正后的框架比正常框架的准确性高出约 1 厘米),而且它们与拍摄对象的人体工学无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A detailed study on human height estimation model that combines video surveillance systems with 3D laser scanning

The increase of video surveillance systems has highlighted the interest in forensic anthropometric analysis of subjects who commit crimes and are captured by cameras during their criminal activities. There are different methodologies for human height estimation. Forensic researchers developed a methodological approach that allows the height of a subject to be estimated through a combined model of 3D laser scanning acquisition and video images acquired by video surveillance systems. The proposed study had highlighted three limits: not assessments had been made for image correction to limit the distortion effect, the method had been tested by only one laboratory and probably height assessment was dependent on the ergonomics. To overcome these limitations, in this paper the analysis was repeated by correcting the images to compare the new results obtained with the previous ones. Furthermore, the same methodological approach was applied by estimating the height of a mannequin, to limit the ergonomic effects, and proposing the same study to three different forensic laboratories to compare the results. The presented study demonstrates the reliability and repeatability of the system, as the results obtained by the three laboratories are very similar. They have obtained the same trend and the maximum estimate distance is approximately 6 cm. Furthermore, it has showed that the accuracy of results is dependent on image correction, which has little impact (approximately 1 cm more accurate on the corrected frame than the normal frame) on the height evaluation and they are not dependent to the ergonomics of the subject captured.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of forensic sciences
Journal of forensic sciences 医学-医学:法
CiteScore
4.00
自引率
12.50%
发文量
215
审稿时长
2 months
期刊介绍: The Journal of Forensic Sciences (JFS) is the official publication of the American Academy of Forensic Sciences (AAFS). It is devoted to the publication of original investigations, observations, scholarly inquiries and reviews in various branches of the forensic sciences. These include anthropology, criminalistics, digital and multimedia sciences, engineering and applied sciences, pathology/biology, psychiatry and behavioral science, jurisprudence, odontology, questioned documents, and toxicology. Similar submissions dealing with forensic aspects of other sciences and the social sciences are also accepted, as are submissions dealing with scientifically sound emerging science disciplines. The content and/or views expressed in the JFS are not necessarily those of the AAFS, the JFS Editorial Board, the organizations with which authors are affiliated, or the publisher of JFS. All manuscript submissions are double-blind peer-reviewed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信