一组健康成年人网织红细胞计数和衍生网织红细胞参数的参考区间。

IF 2.2 4区 医学 Q3 HEMATOLOGY
Yolanda Posada-Franco, Ana García-Álvarez, Elena Hernández-Álvarez, Irene Serrano-García, Rocío Contera-Raposo, Mercedes Martínez-Novillo González, María Teresa Sanz-Casla
{"title":"一组健康成年人网织红细胞计数和衍生网织红细胞参数的参考区间。","authors":"Yolanda Posada-Franco,&nbsp;Ana García-Álvarez,&nbsp;Elena Hernández-Álvarez,&nbsp;Irene Serrano-García,&nbsp;Rocío Contera-Raposo,&nbsp;Mercedes Martínez-Novillo González,&nbsp;María Teresa Sanz-Casla","doi":"10.1111/ijlh.14332","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>Reticulocyte count and novel derived parameters provide insight into the effectiveness of erythropoiesis and may be useful tools in the classification and diagnosis of anemias. However, there is no standardisation, so we consider it necessary that each laboratory evaluates the parameters according to its own methodology and instrumentation and establishes its own reference ranges. Our aim was to establish the reference intervals (RIs) of reticulocyte profile provided by the Beckman Coulter DxH 900 haematological autoanalyzer in our reference population.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>One hundred and seventy-five healthy adults (18 to 62 years) were included. Subjects were collected from the blood donation centre of the Hospital Clínico San Carlos (Madrid, Spain) upon informed consent. Whole blood was collected and assayed for 14 haematological parameters on the Beckman Coulter DxH 900 analyzer in the haematology laboratory of the Clinical Analysis Department. RIs were established as per Clinical and Laboratory Standards Institute EP28-A3c guidelines using three different statistical approaches.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>RIs estimated using the non-parametric method and the Harrell-Davis bootstrap method were very similar. RIs estimated by the robust method were narrower. Gender partitioning was required for two haematological parameters (low haemoglobin density (LHD) and microcytic anaemia factor (MAF)). The rest of the parameters did not need to be partitioned according to Lahti's method.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>RIs have been established for 14 hematologic parameters of the reticulocyte profile for the Beckman Coulter DxH 900 haematology analyzer using a healthy cohort of adult subjects.</p>\n </section>\n </div>","PeriodicalId":14120,"journal":{"name":"International Journal of Laboratory Hematology","volume":"46 6","pages":"997-1003"},"PeriodicalIF":2.2000,"publicationDate":"2024-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reference intervals for reticulocyte count and derived reticulocyte parameters in a cohort of healthy adults\",\"authors\":\"Yolanda Posada-Franco,&nbsp;Ana García-Álvarez,&nbsp;Elena Hernández-Álvarez,&nbsp;Irene Serrano-García,&nbsp;Rocío Contera-Raposo,&nbsp;Mercedes Martínez-Novillo González,&nbsp;María Teresa Sanz-Casla\",\"doi\":\"10.1111/ijlh.14332\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Introduction</h3>\\n \\n <p>Reticulocyte count and novel derived parameters provide insight into the effectiveness of erythropoiesis and may be useful tools in the classification and diagnosis of anemias. However, there is no standardisation, so we consider it necessary that each laboratory evaluates the parameters according to its own methodology and instrumentation and establishes its own reference ranges. Our aim was to establish the reference intervals (RIs) of reticulocyte profile provided by the Beckman Coulter DxH 900 haematological autoanalyzer in our reference population.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>One hundred and seventy-five healthy adults (18 to 62 years) were included. Subjects were collected from the blood donation centre of the Hospital Clínico San Carlos (Madrid, Spain) upon informed consent. Whole blood was collected and assayed for 14 haematological parameters on the Beckman Coulter DxH 900 analyzer in the haematology laboratory of the Clinical Analysis Department. RIs were established as per Clinical and Laboratory Standards Institute EP28-A3c guidelines using three different statistical approaches.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>RIs estimated using the non-parametric method and the Harrell-Davis bootstrap method were very similar. RIs estimated by the robust method were narrower. Gender partitioning was required for two haematological parameters (low haemoglobin density (LHD) and microcytic anaemia factor (MAF)). The rest of the parameters did not need to be partitioned according to Lahti's method.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>RIs have been established for 14 hematologic parameters of the reticulocyte profile for the Beckman Coulter DxH 900 haematology analyzer using a healthy cohort of adult subjects.</p>\\n </section>\\n </div>\",\"PeriodicalId\":14120,\"journal\":{\"name\":\"International Journal of Laboratory Hematology\",\"volume\":\"46 6\",\"pages\":\"997-1003\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Laboratory Hematology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/ijlh.14332\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Laboratory Hematology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ijlh.14332","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

导言:网织红细胞计数和新的衍生参数有助于了解红细胞生成的有效性,并可作为贫血症分类和诊断的有用工具。然而,目前还没有统一的标准,因此我们认为各实验室有必要根据自己的方法和仪器对参数进行评估,并确定自己的参考范围。我们的目的是在参考人群中建立贝克曼库尔特 DxH 900 血液自动分析仪提供的网织红细胞谱参考区间(RIs):纳入 175 名健康成年人(18 至 62 岁)。受试者是在知情同意的情况下从圣卡洛斯医院(西班牙马德里)献血中心采集的。采集全血后,在临床分析部的血液学实验室使用贝克曼库尔特 DxH 900 分析仪检测 14 项血液学参数。根据临床和实验室标准协会 EP28-A3c 指南,采用三种不同的统计方法确定了 RIs:结果:使用非参数法和 Harrell-Davis 引导法估算的 RI 非常相似。采用稳健法估算的 RI 值范围较窄。两个血液学参数(低血红蛋白密度(LHD)和小细胞性贫血因子(MAF))需要进行性别分区。结论:使用贝克曼库尔特 DxH 900 血液分析仪对健康的成年受试者群体进行分析,为网织红细胞图谱的 14 个血液学参数建立了 RIs。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reference intervals for reticulocyte count and derived reticulocyte parameters in a cohort of healthy adults

Introduction

Reticulocyte count and novel derived parameters provide insight into the effectiveness of erythropoiesis and may be useful tools in the classification and diagnosis of anemias. However, there is no standardisation, so we consider it necessary that each laboratory evaluates the parameters according to its own methodology and instrumentation and establishes its own reference ranges. Our aim was to establish the reference intervals (RIs) of reticulocyte profile provided by the Beckman Coulter DxH 900 haematological autoanalyzer in our reference population.

Methods

One hundred and seventy-five healthy adults (18 to 62 years) were included. Subjects were collected from the blood donation centre of the Hospital Clínico San Carlos (Madrid, Spain) upon informed consent. Whole blood was collected and assayed for 14 haematological parameters on the Beckman Coulter DxH 900 analyzer in the haematology laboratory of the Clinical Analysis Department. RIs were established as per Clinical and Laboratory Standards Institute EP28-A3c guidelines using three different statistical approaches.

Results

RIs estimated using the non-parametric method and the Harrell-Davis bootstrap method were very similar. RIs estimated by the robust method were narrower. Gender partitioning was required for two haematological parameters (low haemoglobin density (LHD) and microcytic anaemia factor (MAF)). The rest of the parameters did not need to be partitioned according to Lahti's method.

Conclusion

RIs have been established for 14 hematologic parameters of the reticulocyte profile for the Beckman Coulter DxH 900 haematology analyzer using a healthy cohort of adult subjects.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.50
自引率
6.70%
发文量
211
审稿时长
6-12 weeks
期刊介绍: The International Journal of Laboratory Hematology provides a forum for the communication of new developments, research topics and the practice of laboratory haematology. The journal publishes invited reviews, full length original articles, and correspondence. The International Journal of Laboratory Hematology is the official journal of the International Society for Laboratory Hematology, which addresses the following sub-disciplines: cellular analysis, flow cytometry, haemostasis and thrombosis, molecular diagnostics, haematology informatics, haemoglobinopathies, point of care testing, standards and guidelines. The journal was launched in 2006 as the successor to Clinical and Laboratory Hematology, which was first published in 1979. An active and positive editorial policy ensures that work of a high scientific standard is reported, in order to bridge the gap between practical and academic aspects of laboratory haematology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信