{"title":"地基静电悬浮加速度计","authors":"Hanxiao Liu, Xiaoxia He, Chenhui Wu, Rong Zhang","doi":"10.3390/s24124029","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, we have developed an electrostatically suspended accelerometer (ESA) specifically designed for ground use. To ensure sufficient overload capacity and minimize noise resulting from high suspension voltage, we introduced a proof mass design featuring a hollow, thin-walled cylinder with a thin flange fixed at the center, offering the highest surface-area-to-mass ratio compared to various typical proof mass structures. Preload voltage is directly applied to the proof mass via a golden wire, effectively reducing the maximum supply voltage for suspension. The arrangement of suspension electrodes, offering five degrees of freedom and minimizing cross-talk, was designed to prioritize simplicity and maximize the utilization of electrode area for suspension purposes. The displacement detection and electrostatic suspension force were accurately modeled based on the structure. A controller incorporating an inverse winding mechanism was developed and simulated using Simulink. The simulation results unequivocally demonstrate the successful completion of the stable initial levitation process and suspension under ±1g overload.</p>","PeriodicalId":21698,"journal":{"name":"Sensors","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11207651/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Ground-Based Electrostatically Suspended Accelerometer.\",\"authors\":\"Hanxiao Liu, Xiaoxia He, Chenhui Wu, Rong Zhang\",\"doi\":\"10.3390/s24124029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In this study, we have developed an electrostatically suspended accelerometer (ESA) specifically designed for ground use. To ensure sufficient overload capacity and minimize noise resulting from high suspension voltage, we introduced a proof mass design featuring a hollow, thin-walled cylinder with a thin flange fixed at the center, offering the highest surface-area-to-mass ratio compared to various typical proof mass structures. Preload voltage is directly applied to the proof mass via a golden wire, effectively reducing the maximum supply voltage for suspension. The arrangement of suspension electrodes, offering five degrees of freedom and minimizing cross-talk, was designed to prioritize simplicity and maximize the utilization of electrode area for suspension purposes. The displacement detection and electrostatic suspension force were accurately modeled based on the structure. A controller incorporating an inverse winding mechanism was developed and simulated using Simulink. The simulation results unequivocally demonstrate the successful completion of the stable initial levitation process and suspension under ±1g overload.</p>\",\"PeriodicalId\":21698,\"journal\":{\"name\":\"Sensors\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11207651/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.3390/s24124029\",\"RegionNum\":3,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.3390/s24124029","RegionNum":3,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
A Ground-Based Electrostatically Suspended Accelerometer.
In this study, we have developed an electrostatically suspended accelerometer (ESA) specifically designed for ground use. To ensure sufficient overload capacity and minimize noise resulting from high suspension voltage, we introduced a proof mass design featuring a hollow, thin-walled cylinder with a thin flange fixed at the center, offering the highest surface-area-to-mass ratio compared to various typical proof mass structures. Preload voltage is directly applied to the proof mass via a golden wire, effectively reducing the maximum supply voltage for suspension. The arrangement of suspension electrodes, offering five degrees of freedom and minimizing cross-talk, was designed to prioritize simplicity and maximize the utilization of electrode area for suspension purposes. The displacement detection and electrostatic suspension force were accurately modeled based on the structure. A controller incorporating an inverse winding mechanism was developed and simulated using Simulink. The simulation results unequivocally demonstrate the successful completion of the stable initial levitation process and suspension under ±1g overload.
期刊介绍:
Sensors (ISSN 1424-8220) provides an advanced forum for the science and technology of sensors and biosensors. It publishes reviews (including comprehensive reviews on the complete sensors products), regular research papers and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.