经颅磁刺激初级运动皮层可立即产生经颅诱发电位。

IF 7.6 1区 医学 Q1 CLINICAL NEUROLOGY
Mikkel Malling Beck , Lasse Christiansen , Mads Alexander Just Madsen , Armita Faghani Jadidi , Mikkel Christoffer Vinding , Axel Thielscher , Til Ole Bergmann , Hartwig Roman Siebner , Leo Tomasevic
{"title":"经颅磁刺激初级运动皮层可立即产生经颅诱发电位。","authors":"Mikkel Malling Beck ,&nbsp;Lasse Christiansen ,&nbsp;Mads Alexander Just Madsen ,&nbsp;Armita Faghani Jadidi ,&nbsp;Mikkel Christoffer Vinding ,&nbsp;Axel Thielscher ,&nbsp;Til Ole Bergmann ,&nbsp;Hartwig Roman Siebner ,&nbsp;Leo Tomasevic","doi":"10.1016/j.brs.2024.06.008","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Transcranial evoked potentials (TEPs) measured via electroencephalography (EEG) are widely used to study the cortical responses to transcranial magnetic stimulation (TMS). Immediate transcranial evoked potentials (i-TEPs) have been obscured by pulse and muscular artifacts. Thus, the TEP peaks that are commonly reported have latencies that are too long to be caused by direct excitation of cortical neurons.</p></div><div><h3>Methods</h3><p>In 25 healthy individuals, we recorded i-TEPs evoked by a single biphasic TMS pulse targeting the primary motor hand area (M1<sub>HAND</sub>) or parietal or midline control sites. Sampling EEG at 50 kHz enabled us to reduce the duration of the TMS pulse artifact to a few milliseconds, while minor adjustments of the TMS coil tilt or position enabled us to avoid cranial muscular twitches during the experiment.</p></div><div><h3>Results</h3><p>We observed an early positive EEG deflection starting after approx. 2 ms followed by a series of superimposed peaks with an inter-peak interval of ∼1.1–1.4 ms in multiple electrodes surrounding the stimulated sensorimotor region. This multi-peak i-TEP response was only evoked by TMS of the M1<sub>HAND</sub> region and was modified by changes in stimulation intensity and current direction.</p></div><div><h3>Discussion</h3><p>Single-pulse TMS of the M1<sub>HAND</sub> evokes an immediate local multi-peak response at the cortical site of stimulation. Our results suggest that the observed i-TEP patterns are genuine cortical responses evoked by TMS caused by synchronized excitation of pyramidal neurons in the targeted precentral cortex. This notion needs to be corroborated in future studies, including further investigations into the potential contribution of instrumental or physiological artifacts.</p></div>","PeriodicalId":9206,"journal":{"name":"Brain Stimulation","volume":"17 4","pages":"Pages 802-812"},"PeriodicalIF":7.6000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1935861X24001141/pdfft?md5=1d5edd12ef2722d2c9efe9e9da4ed380&pid=1-s2.0-S1935861X24001141-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Transcranial magnetic stimulation of primary motor cortex elicits an immediate transcranial evoked potential\",\"authors\":\"Mikkel Malling Beck ,&nbsp;Lasse Christiansen ,&nbsp;Mads Alexander Just Madsen ,&nbsp;Armita Faghani Jadidi ,&nbsp;Mikkel Christoffer Vinding ,&nbsp;Axel Thielscher ,&nbsp;Til Ole Bergmann ,&nbsp;Hartwig Roman Siebner ,&nbsp;Leo Tomasevic\",\"doi\":\"10.1016/j.brs.2024.06.008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Transcranial evoked potentials (TEPs) measured via electroencephalography (EEG) are widely used to study the cortical responses to transcranial magnetic stimulation (TMS). Immediate transcranial evoked potentials (i-TEPs) have been obscured by pulse and muscular artifacts. Thus, the TEP peaks that are commonly reported have latencies that are too long to be caused by direct excitation of cortical neurons.</p></div><div><h3>Methods</h3><p>In 25 healthy individuals, we recorded i-TEPs evoked by a single biphasic TMS pulse targeting the primary motor hand area (M1<sub>HAND</sub>) or parietal or midline control sites. Sampling EEG at 50 kHz enabled us to reduce the duration of the TMS pulse artifact to a few milliseconds, while minor adjustments of the TMS coil tilt or position enabled us to avoid cranial muscular twitches during the experiment.</p></div><div><h3>Results</h3><p>We observed an early positive EEG deflection starting after approx. 2 ms followed by a series of superimposed peaks with an inter-peak interval of ∼1.1–1.4 ms in multiple electrodes surrounding the stimulated sensorimotor region. This multi-peak i-TEP response was only evoked by TMS of the M1<sub>HAND</sub> region and was modified by changes in stimulation intensity and current direction.</p></div><div><h3>Discussion</h3><p>Single-pulse TMS of the M1<sub>HAND</sub> evokes an immediate local multi-peak response at the cortical site of stimulation. Our results suggest that the observed i-TEP patterns are genuine cortical responses evoked by TMS caused by synchronized excitation of pyramidal neurons in the targeted precentral cortex. This notion needs to be corroborated in future studies, including further investigations into the potential contribution of instrumental or physiological artifacts.</p></div>\",\"PeriodicalId\":9206,\"journal\":{\"name\":\"Brain Stimulation\",\"volume\":\"17 4\",\"pages\":\"Pages 802-812\"},\"PeriodicalIF\":7.6000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1935861X24001141/pdfft?md5=1d5edd12ef2722d2c9efe9e9da4ed380&pid=1-s2.0-S1935861X24001141-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brain Stimulation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1935861X24001141\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brain Stimulation","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1935861X24001141","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:通过脑电图(EEG)测量的经颅诱发电位(TEPs)被广泛用于研究大脑皮层对经颅磁刺激(TMS)的反应。即时经颅诱发电位(i-TEPs)被脉冲和肌肉伪影所掩盖。因此,通常报告的经颅诱发电位峰值的潜伏期太长,不可能是由大脑皮层神经元的直接兴奋引起的:在 25 名健康人中,我们记录了针对主要运动手区 (M1HAND) 或顶叶或中线控制点的单个双相 TMS 脉冲所诱发的 i-TEPs。50 kHz 的脑电图采样使我们能够将 TMS 脉冲假象的持续时间缩短至几毫秒,而 TMS 线圈倾斜度或位置的微小调整使我们能够在实验过程中避免颅部肌肉抽搐:我们在受刺激的感觉运动区周围的多个电极上观察到了约 2 毫秒后开始的早期正向脑电图偏转,随后出现了一系列叠加峰,峰间间隔为 1.1-1.4 毫秒。这种多峰i-TEP反应仅由M1HAND区域的TMS诱发,并随刺激强度和电流方向的改变而改变:讨论:M1HAND 的单脉冲经颅磁刺激可在皮层刺激部位立即引起局部多峰值反应。我们的研究结果表明,观察到的 i-TEP 模式是由 TMS 引起的真正的皮质反应,它是由目标前区皮质中锥体神经元的同步兴奋引起的。这一观点需要在今后的研究中得到证实,包括进一步研究仪器或生理伪影可能造成的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transcranial magnetic stimulation of primary motor cortex elicits an immediate transcranial evoked potential

Background

Transcranial evoked potentials (TEPs) measured via electroencephalography (EEG) are widely used to study the cortical responses to transcranial magnetic stimulation (TMS). Immediate transcranial evoked potentials (i-TEPs) have been obscured by pulse and muscular artifacts. Thus, the TEP peaks that are commonly reported have latencies that are too long to be caused by direct excitation of cortical neurons.

Methods

In 25 healthy individuals, we recorded i-TEPs evoked by a single biphasic TMS pulse targeting the primary motor hand area (M1HAND) or parietal or midline control sites. Sampling EEG at 50 kHz enabled us to reduce the duration of the TMS pulse artifact to a few milliseconds, while minor adjustments of the TMS coil tilt or position enabled us to avoid cranial muscular twitches during the experiment.

Results

We observed an early positive EEG deflection starting after approx. 2 ms followed by a series of superimposed peaks with an inter-peak interval of ∼1.1–1.4 ms in multiple electrodes surrounding the stimulated sensorimotor region. This multi-peak i-TEP response was only evoked by TMS of the M1HAND region and was modified by changes in stimulation intensity and current direction.

Discussion

Single-pulse TMS of the M1HAND evokes an immediate local multi-peak response at the cortical site of stimulation. Our results suggest that the observed i-TEP patterns are genuine cortical responses evoked by TMS caused by synchronized excitation of pyramidal neurons in the targeted precentral cortex. This notion needs to be corroborated in future studies, including further investigations into the potential contribution of instrumental or physiological artifacts.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Brain Stimulation
Brain Stimulation 医学-临床神经学
CiteScore
13.10
自引率
9.10%
发文量
256
审稿时长
72 days
期刊介绍: Brain Stimulation publishes on the entire field of brain stimulation, including noninvasive and invasive techniques and technologies that alter brain function through the use of electrical, magnetic, radiowave, or focally targeted pharmacologic stimulation. Brain Stimulation aims to be the premier journal for publication of original research in the field of neuromodulation. The journal includes: a) Original articles; b) Short Communications; c) Invited and original reviews; d) Technology and methodological perspectives (reviews of new devices, description of new methods, etc.); and e) Letters to the Editor. Special issues of the journal will be considered based on scientific merit.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信