偏头痛患者颅颈屈曲测试的可靠性和结构有效性

IF 3.1 3区 医学 Q1 ORTHOPEDICS
Amanda Rodrigues , Gabriela Ferreira Carvalho , Lidiane Lima Florencio , Jaqueline Martins , Carina Ferreira Pinheiro-Araújo , Milena Dietrich Deitos Rosa , Fabíola Dach , Débora Bevilaqua-Grossi
{"title":"偏头痛患者颅颈屈曲测试的可靠性和结构有效性","authors":"Amanda Rodrigues ,&nbsp;Gabriela Ferreira Carvalho ,&nbsp;Lidiane Lima Florencio ,&nbsp;Jaqueline Martins ,&nbsp;Carina Ferreira Pinheiro-Araújo ,&nbsp;Milena Dietrich Deitos Rosa ,&nbsp;Fabíola Dach ,&nbsp;Débora Bevilaqua-Grossi","doi":"10.1016/j.bjpt.2024.101085","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Migraine may be accompanied by several cervical musculoskeletal dysfunctions, for example an altered performance on the Craniocervical Flexion Test (CCFT). However, CCFT measurement properties are still unclear in patients with migraine.</p></div><div><h3>Objectives</h3><p>To determine intra- and inter-examiner reliability, construct validity, standard measurement error (SEM), and minimal detectable change (MDC) of the CCFT in patients with migraine.</p></div><div><h3>Methods</h3><p>Women diagnosed with migraine were considered eligible for this study. Participants were assessed by two examiners for the inter-examiner reliability, and with 7–10 days interval for the intra-examiner reliability. Construct validity was assessed considering headache and neck pain frequency and intensity, and self-reported questionnaires, including the Headache Impact Test – 6 items (HIT-6), the 12-item Allodynia Symptom Checklist/Brazil (ASC-12), and the Neck Disability Index (NDI). In addition, participants performed cervical endurance and maximal voluntary isometric contraction of the cervical flexors.</p></div><div><h3>Results</h3><p>A total of 103 women with migraine were recruited. The intra-examiner reliability was rated as good (ICC= 0.81, 95% CI: 0.73, 0.87), while the inter-examiner reliability was rated as moderate (ICC= 0.55, 95% CI: 0.40, 0.67). The intra and inter-examiner SEM were 1.31 and 1.36 mmHg respectively, and MDC were 3.63 and 3.77 mmHg. The HIT-6 and the cervical endurance flexion test were associated with the CCFT in a multiple linear regression model (<em>p</em> = 0.004, <em>R</em> = 0.35).</p></div><div><h3>Conclusion</h3><p>The CCFT presents adequate intra- and inter-examiner reliability. Better performance on the CCFT test was associated with better HIT-6 scores and greater cervical endurance time, which was not influenced by the presence of neck pain.</p></div>","PeriodicalId":49621,"journal":{"name":"Brazilian Journal of Physical Therapy","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability and construct validity of the Craniocervical Flexion Test in patients with migraine\",\"authors\":\"Amanda Rodrigues ,&nbsp;Gabriela Ferreira Carvalho ,&nbsp;Lidiane Lima Florencio ,&nbsp;Jaqueline Martins ,&nbsp;Carina Ferreira Pinheiro-Araújo ,&nbsp;Milena Dietrich Deitos Rosa ,&nbsp;Fabíola Dach ,&nbsp;Débora Bevilaqua-Grossi\",\"doi\":\"10.1016/j.bjpt.2024.101085\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Migraine may be accompanied by several cervical musculoskeletal dysfunctions, for example an altered performance on the Craniocervical Flexion Test (CCFT). However, CCFT measurement properties are still unclear in patients with migraine.</p></div><div><h3>Objectives</h3><p>To determine intra- and inter-examiner reliability, construct validity, standard measurement error (SEM), and minimal detectable change (MDC) of the CCFT in patients with migraine.</p></div><div><h3>Methods</h3><p>Women diagnosed with migraine were considered eligible for this study. Participants were assessed by two examiners for the inter-examiner reliability, and with 7–10 days interval for the intra-examiner reliability. Construct validity was assessed considering headache and neck pain frequency and intensity, and self-reported questionnaires, including the Headache Impact Test – 6 items (HIT-6), the 12-item Allodynia Symptom Checklist/Brazil (ASC-12), and the Neck Disability Index (NDI). In addition, participants performed cervical endurance and maximal voluntary isometric contraction of the cervical flexors.</p></div><div><h3>Results</h3><p>A total of 103 women with migraine were recruited. The intra-examiner reliability was rated as good (ICC= 0.81, 95% CI: 0.73, 0.87), while the inter-examiner reliability was rated as moderate (ICC= 0.55, 95% CI: 0.40, 0.67). The intra and inter-examiner SEM were 1.31 and 1.36 mmHg respectively, and MDC were 3.63 and 3.77 mmHg. The HIT-6 and the cervical endurance flexion test were associated with the CCFT in a multiple linear regression model (<em>p</em> = 0.004, <em>R</em> = 0.35).</p></div><div><h3>Conclusion</h3><p>The CCFT presents adequate intra- and inter-examiner reliability. Better performance on the CCFT test was associated with better HIT-6 scores and greater cervical endurance time, which was not influenced by the presence of neck pain.</p></div>\",\"PeriodicalId\":49621,\"journal\":{\"name\":\"Brazilian Journal of Physical Therapy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brazilian Journal of Physical Therapy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1413355524004957\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Physical Therapy","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1413355524004957","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

背景偏头痛可能伴有多种颈椎肌肉骨骼功能障碍,例如颅颈屈曲测试(CCFT)的表现会发生改变。目的 测定偏头痛患者颅颈屈曲测试(CCFT)在检查者内部和检查者之间的可靠性、结构效度、标准测量误差(SEM)和最小可检测变化(MDC)。由两名检查员对参与者进行评估,以确定检查员之间的信度;间隔 7-10 天对参与者进行评估,以确定检查员内部的信度。结构效度的评估考虑了头痛和颈部疼痛的频率和强度,以及自我报告问卷,包括头痛影响测试 - 6 个项目(HIT-6)、12 个项目的巴西过敏症状检查表(ASC-12)和颈部残疾指数(NDI)。此外,参与者还进行了颈椎耐力和颈屈肌最大自主等长收缩。检查者内部的可靠性被评为良好(ICC= 0.81,95% CI:0.73,0.87),而检查者之间的可靠性被评为中等(ICC= 0.55,95% CI:0.40,0.67)。检查者内部和检查者之间的 SEM 分别为 1.31 和 1.36 mmHg,MDC 分别为 3.63 和 3.77 mmHg。在多元线性回归模型中,HIT-6 和颈椎耐力屈曲测试与 CCFT 相关(p = 0.004,R = 0.35)。CCFT测试成绩越好,HIT-6评分越高,颈椎耐力时间越长,这与是否存在颈部疼痛无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reliability and construct validity of the Craniocervical Flexion Test in patients with migraine

Background

Migraine may be accompanied by several cervical musculoskeletal dysfunctions, for example an altered performance on the Craniocervical Flexion Test (CCFT). However, CCFT measurement properties are still unclear in patients with migraine.

Objectives

To determine intra- and inter-examiner reliability, construct validity, standard measurement error (SEM), and minimal detectable change (MDC) of the CCFT in patients with migraine.

Methods

Women diagnosed with migraine were considered eligible for this study. Participants were assessed by two examiners for the inter-examiner reliability, and with 7–10 days interval for the intra-examiner reliability. Construct validity was assessed considering headache and neck pain frequency and intensity, and self-reported questionnaires, including the Headache Impact Test – 6 items (HIT-6), the 12-item Allodynia Symptom Checklist/Brazil (ASC-12), and the Neck Disability Index (NDI). In addition, participants performed cervical endurance and maximal voluntary isometric contraction of the cervical flexors.

Results

A total of 103 women with migraine were recruited. The intra-examiner reliability was rated as good (ICC= 0.81, 95% CI: 0.73, 0.87), while the inter-examiner reliability was rated as moderate (ICC= 0.55, 95% CI: 0.40, 0.67). The intra and inter-examiner SEM were 1.31 and 1.36 mmHg respectively, and MDC were 3.63 and 3.77 mmHg. The HIT-6 and the cervical endurance flexion test were associated with the CCFT in a multiple linear regression model (p = 0.004, R = 0.35).

Conclusion

The CCFT presents adequate intra- and inter-examiner reliability. Better performance on the CCFT test was associated with better HIT-6 scores and greater cervical endurance time, which was not influenced by the presence of neck pain.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.10
自引率
8.80%
发文量
53
审稿时长
74 days
期刊介绍: The Brazilian Journal of Physical Therapy (BJPT) is the official publication of the Brazilian Society of Physical Therapy Research and Graduate Studies (ABRAPG-Ft). It publishes original research articles on topics related to the areas of physical therapy and rehabilitation sciences, including clinical, basic or applied studies on the assessment, prevention, and treatment of movement disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信